If you find any incorrectly arranged or missing pages in this manual, they will be replaced. If the manual it gets lost or soiled, a new copy can be provided for a fee. In either case, please contact Kikusui distributor/agent, and provide the “Part No.” given on the cover.
Page 3
The rating of this product's input fuse is ̲̲̲̲̲̲̲̲̲̲̲̲ A, ̲̲̲̲̲̲̲̲̲̲̲ VAC, and ̲̲̲̲̲̲̲̲̲̲̲ . WARNING ・ To avoid electrical shock, always disconnect the AC power cord or turn off the switch on the switchboard before attempting to check or replace the fuse. ・ Use a fuse element having a shape, rating, and characteristics suitable for this product. The use of a fuse with a different rating or one that short circuits the fuse holder may result in fire, electric shock, or irreparable damage. DPO2212A...
Page 4
White (NEUTRAL) Black (LIVE) Brown (LIVE) Green/Yellow (GND) Green or Green/Yellow (GND) Plugs for USA Plugs for Europe Provided by Kikusui distributor/agent Kikusui agents can provide you with suitable AC power cord. For further information, contact Kikusui distributor/agent. -ii- DPO2212A...
PAD 16-100L PAD 110-30L PAD 35-50L PAD 110-60L PAD 35-60L PAD 250-8L PAD 35-100L PAD 250-15L PAD 35-200L PAD 300-1A PAD 35-200LT PAD 500-0.6A PAD 55-35L PAD 500-1.2A PAD 55-60L PAD 500-2L PAD 55-120L PAD 600-1.5L PAD 110-20L PAD 1K-0.2L DPO2212A...
For details, see the relevant page of this operation manual. Fuse • With products with a fuse holder on the exterior surface, the fuse can be replaced with a new one. -iv- DPO2212A...
Page 7
Also handle carefully when relocating tall products as they can fall over easily. • Be sure the operation manual be included when the product is relocated. DPO2212A...
Page 8
, c h e c k i n g , c l e a n i n g , a n d calibration be performed. Service • Internal service is to be done by Kikusui service engineers. If the product must be adjusted or repaired, contact Kikusui distributor/agent.
3-1. Notes Before Use ................. 5 3-1-1.System Structure ..............5 3-1-2.AC Line Voltage ..............7 3-1-3.Requirements of Place of lnstallation ........8 3-2. Description of Components ............9 3-3. Connections and Settings ............13 3-3-1.Connection Between DPO2212A and GP-IB Cable ..13 3-3-2.Setting Address ..............13 3-4. Operating Instructions for Analog Outputs ....... 14 3-4-1.Connection to Power Supply ..........14 3-4-2.Code Format Setting ............24 3-4-3.Overall System Adjustment ..........25 3-4-4.Notes for Use of System .............
2) The items which can be controlled by one DPO2212A for one power supply are as shown in Table 3-2. Table 3-2 Voltage Current Voltage Mode Abnormality Power Only Only and Current Interruption Interruption PAA *5 ○ ○ ○ × × ○...
Page 15
I2 Power Supplies, the rectifier circuit is blocked (stops). *5:Of the PAA Power Supplies, the very low portion (close to 0V or 0A) drops out and cannot be successfully controlled. Only the range within the specification can be controlled. *6:DPO2212A is not available to PAD1K-0.2L. DPO2212A...
Figure 3-2. WARNING • It is necessary to open the external cover of DPO2212A to replace the input fuse. There are parts that may cause physical hazards inside the DPO2212A. Do not remove the external cover.
Note:When range C or D is specified when ordering, the DPO2212A is shipped without any plug or solderless terminal provided at the end of the power cord.
3-3-2. Setting Address ○ An address for the DPO2212A on the GP-IB bus can be set with the ADDRESS switch. The switch has eight element switches and five of which are used as digital switches to set an address for the DPO2212A.
Page 24
Figure 3-5 Note:Of the PAA Series Power Supplies, REMOTE/ LOCAL mode selection by the rear panel switch of the DPO2212A is unavailable. ○ PAB-A Series (A1 for output current or voltage control) Selection between output voltage control and output current control should be done inside the PAB-A Power Supply.
Page 25
A2 for output current control) Figure 3-7 Type I3 (A1 for output voltage control and A2 for output current control) Figure 3-8 Types II, III, IV, V, VI (A1 for output voltage control and A2 for output current control) Figure 3-9 DPO2212A...
Page 26
Figure 3-10 ○ PAK Series (A1 for output voltage control and A2 for output current control) Figure 3-11 To switch between Remote and Local, use SW1 and SW2 on the rear panel of the PAK series. DPO2212A...
Page 27
J1.J2 4PIN D COM Figure 3-13 Note:When connecting a shield to the DPO2212A, insulate the shield without connecting it to the case of the power supply. To switch between Remote and Local, use the switch on the control panel of the PAN series. For details, refer to the operation manual of the PAN series.
Page 28
J1.J2 4PIN A COM Figure 3-14 Note: When connecting a shield to the DPO2212A, insulate the shield without connecting it to the case of the power supply. To switch between Remote and Local, use the switch on the control panel of the PAN-A series. For details, refer to the operation manual of the PAN-A series.
Page 29
Series (A1 for output voltage control and A2 for output current control) To control output voltage and output current with the DPO2212A, optional remote control board for the PAR series is necessary. Figure 3-15 To switch between Remote and Local, use the remote/ local switch on the front panel of the PAR series.
Page 30
4PIN D COM Figure 3-17 The output range of the DPO2212A is the HI range. To switch between Remote and Local, use the function switch on the front panel of the PLZ-W series. For details, refer to the operation manual of the PLZ-W series.
Page 31
Provided wire kit Connector(Molex:5264-12) Figure 3-19 The output range of the DPO2212A is the HI range. To switch between Remote and Local, use the EXT/ INT switch on the front panel of the PLZ-WU series. For details, refer to the operation manual of the PLZ-WU series.
Page 32
J1.J2 4PIN Figure 3-21 The output range of the DPO2212A is the HI range. To switch between Remote and Local, use the EXT/ INT switch on the front panel of the PMC-A series. For details, refer to the operation manual of the PMC-A series.
3-5. Instructions for Digital I/O 3-5-1. Interruption The digital I/O connectors of the DPO2212A have 4-bit interrupt signal input pins and deliver a service request (SRQ) signal onto the GP-IB bus when an interruption has occurred. They also deliver a status byte in response to poll.
Ideally, you will be able to cure these symptoms without difficulty. When you find a relevant item, follow the corresponding remedy. If this does not solve or improve the problem, or if no relevant item can be located, please contact Kikusui distributor/agent. DPO2212A...