UNIVIEW OET-213H-BTS1 Quick Manual

Face recognition access control terminal

Advertisement

Face Recognition Access Control Terminal
Quick Guide
V1.00

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the OET-213H-BTS1 and is the answer not in the manual?

Questions and answers

Summary of Contents for UNIVIEW OET-213H-BTS1

  • Page 1 Face Recognition Access Control Terminal Quick Guide V1.00...
  • Page 2: Table Of Contents

    Contents 1 Packing List · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · · 1 2 Product Overview ·...
  • Page 3: Packing List

    Packing List Name Unit Face recognition access control terminal Screw component Bracket T10 box-end wrench with hole-L shape Installation sticker 20-pin cable 2-pin power cable User manual Product Overview The face recognition access control terminal features high performance and high reliability.
  • Page 4: Appearance And Dimension

    Appearance and Dimension The actual device appearance shall prevail. The figure below shows the dimension of the device. A waterproof hood is required in waterproof installation. The figure below shows the dimensions of the waterproof hood.
  • Page 5: Structure Description

    Structure Description The figure below shows the structure of the device. The actual device shall prevail. Figure 2-1 Device Structure 1.Light supplement lamp 1 2.Infrared camera 3.Infrared light supplement lamp 4.Visible light camera 5.Light supplement lamp 2 6.Display screen 7.Pass-through indicator 8.Microphone 9.Card reading area 10.Loudspeaker...
  • Page 6: Device Installation

    Device Installation Installation Environment Try to avoid intense direct light and intense backlighting scenes when installing the device. Please keep the ambient light bright. Device Wiring 1 Wiring Embedding Before installing the face recognition access control terminal, plan the layout of cables, including the power cable (for the diameter selection for the extension power cable, see Table 3-1), network cable, door lock cable, Wiegand cable, alarm cable, and RS485 (RS232) cable.
  • Page 7 Figure 3-1 Wiring Schematic Diagrams (without Security Module) VDD12V RED +12V Power input BLACK Alarm input ALARM_IN0 WHITE/GREEN device BLACK Alarm input Alarm input ALARM_IN1 WHITE/BLUE device Alarm output ALARM_OUT_NC GREEN device Power ALARM_OUT_COM WHITE/PURPLE Alarm output supply ALARM_OUT_NO WHITE/ORANGE Alarm output device RS485_P ORANGE...
  • Page 8: Tools Preparations

    Tools Preparations  Phillips screwdriver  Antistatic wrist strap or antistatic gloves  Drill  Tape measure  Marker  Plenty of silicone rubber  Silicone gun Installation Steps 1. Determine the position of the 86*86mm 2. Determine the positions of holes on wall-mounted junction box.
  • Page 9 3. Use a drill to drill two holes with the 4. Embed expansion bolts inside the depth of 30mm and diameter of 6mm to two installation holes on the wall. 6.5mm on the wall. Wall Wall Note: Avoid embedded wires in the wall during drilling! 5.
  • Page 10: Device Startup

    6. Fasten the access control terminal to the 7. At the bottom of the device (dotted bracket hook. box as shown in the figure below), use the L-shape wrench to tighten the two fastening screws clockwise. Device Startup After the device is installed correctly, connect one end of the power adapter (purchased or prepared) to the mains supply and the other end to the power interface of the face recognition access control terminal, and then start the device.
  • Page 11: Web Login

    Web Login You can log in to the Web page of the access control terminal to manage and maintain the device. For detailed operations, see the Visual Intercom Face Recognition Terminal User Manual. On a client PC, open the Internet Explorer (IE9 or later), enter the IP address of the device 192.168.1.13 into the address bar, and press Enter.
  • Page 12: Appendix

     Personnel management on the GUI 1. Tap and hold the main interface of the face recognition access control terminal (for more than 3s). On the displayed password input interface, enter the correct activation password to go to the Activation Config interface. On the Activation Config interface, click User Management.
  • Page 13: Face Match Position

    7.1.2 Face Match Position The figure below shows the correct face match position. Figure 7-1 Face Match Position Note: Wall Range of recognizable distance: 0.5m to 2m. Matchable range 1.5m 0.5m Ground 0.5m 1.5m NOTE! The face match position should be within the recognizable range shown in the figure.
  • Page 14 2 Facial Posture To ensure the accuracy of face match, keep the face facing the recognition window during the match. Avoid the head to one side, side face, head too high, head too low, and other incorrect postures. Head to Side Head Head...
  • Page 15: Disclaimer And Safety Warnings

     To the extent allowed by applicable law, in no event shall Uniview’s total liability to you for all damages for the product described in this manual (other than as may be required by applicable law in cases involving personal injury) exceed the amount of money that you have paid for the product.
  • Page 16  Verify that the device is properly installed before connecting it to power.  Do not remove the seal from the device body without consulting Uniview first. Do not attempt to service the product yourself. Contact a trained professional for maintenance.
  • Page 17 (2) this device must accept any interference received, including interference that may cause undesired operation. Compliance Information Statement refer to: http://en.uniview.com/Support/Download_Center/Product_Installation/Declaration/ Caution: The user is cautioned that changes or modifications not expressly approved by the party responsible for compliance could void the user's authority to operate the equipment.
  • Page 18 ce matériel est conforme aux limites de dose d'exposition aux rayonnements, FCC / CNR-102 énoncée dans un autre environnement.cette eqipment devrait être installé et exploité avec distance minimale de 20 entre le radiateur et votre corps. LVD/EMC Directive This product complies with the European Low Voltage Directive 2014/35/EU and EMC Directive 2014/30/EU, 2014/53/EU.
  • Page 19 Better Security, Better World www.uniview.com globalsupport@uniview.com...

Table of Contents