1. saFety
i
1.1.
electrical saFety
Warning! It is the user's responsibility to check the following:
Check all electrical equipment and appliances to ensure that they are safe before using. Inspect power supply leads, plugs and
all electrical connections for wear and damage. Sealey recommend that an RCd (Residual Current device) is used with all electrical
products. You may obtain an RCd by contacting your local Sealey stockist.
If the product is used in the course of business duties, it must be maintained in a safe condition and routinely PAT (Portable
Appliance Test) tested.
electrical safety information, it is important that the following information is read and understood.
1.1.1.
ensure that the insulation on all cables and on the appliance is safe before connecting it to the power supply.
1.1.2.
Regularly inspect power supply cables and plugs for wear or damage and check all connections to ensure that they are secure.
1.1.3.
important: Ensure that the voltage rating on the appliance suits the power supply to be used and that the plug is fitted with the
correct fuse - see fuse rating in these instructions.
Do not pull or carry the appliance by the power cable.
8
Do not pull the plug from the socket by the cable.
8
Do not use worn or damaged cables, plugs or connectors. ensure that any faulty item is repaired or
8
replaced immediately by a qualified electrician.
Warning! Before starting any repair, maintenance or cleaning always disconnect the power.
1.1.4.
This product is fitted with a BS1363/A 13 Amp 3 pin plug.
If the cable or plug is damaged during use, switch the electricity supply and remove from use.
Ensure that repairs are carried out by a qualified electrician.
Replace a damaged plug with a BS1363/A 13 Amp 3 pin plug. If in doubt contact a qualified electrician.
a) Connect the GREEN/YELLOW earth wire to the earth terminal 'E'.
b) Connect the BROWN live wire to the live terminal 'L'.
c) Connect the BLUE neutral wire to the neutral terminal 'N'.
ensure that the cable outer sheath extends inside the cable restraint and that the restraint is tight.
Sealey recommend that repairs are carried out by a qualified electrician.
1.2.
saFety anD maintenance
Keep the log splitter clean for best and safest performance.
9
maintain the log splitter in good condition (use an authorised service agent).
9
Prior to every use check all electrical connections, hydraulic pipes, hoses and safety / stopping devices.
9
Use a qualified person to lubricate and maintain the log splitter.
9
Do not use brake fluid to top up hydraulic unit.
8
Do not operate the log splitter if damaged.
8
Replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty.
9
1.3.
WorKsHop/environmental saFety
locate the log splitter on dry, level and solid ground in a suitable work area with adequate lighting. Fix securely in place using anchor bolts.
9
Keep the area clean and tidy and free from unrelated materials. Do not leave tools, logs or other items lying around where they could
9
become a tripping hazard.
Do not operate the log splitter in wet or damp areas or expose it to rain.
8
Do not operate the log splitter in areas where fumes from paint, solvents, or flammable liquids pose a potential hazard.
8
1.4.
operator saFety
Remove ill fitting clothing. Remove ties, watches, rings and other loose jewellery, and contain long hair.
9
Wear protective, electrically non conductive gloves.
9
Always wear safety goggles. everyday spectacles are not sufficient protection.
9
maintain correct balance and footing, Do not over-reach. ensure the floor is not slippery and wear non-slip, protective footwear.
9
Do not allow untrained persons to operate the log splitter.
8
Do not operate the log splitter with the guards or guides removed.
8
Do not operate the log splitter when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
Do not attempt to load a log until the log pusher has returned to the stop position.
8
Stay alert and always pay attention to the movement of the machine and the work piece.
9
The log splitter must always be operated by one person only.
9
© Jack Sealey limited
6tonne vertical type log splitter
550mm capacity
model no:
Wear eye
Wear ear
Wear protective
protection
protection
Original Language Version
ls550v
Warning!
Warning!:
clothing
no reaching
Keep out of
Wear safety
rain
footwear
in.
Recommended fuse rating
13 Amp
lS550V
Issue 2 (2)
02/10/19

Advertisement

loading

Summary of Contents for Sealey LS550V

  • Page 1 IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE PURPOSE FOR WHICH IT IS INTENDED.
  • Page 2: General Safety

    Features a two hand safety operation, twin pull-in and push-down levers. Fitted with new Ce standard guard. 3. speciFication maximum load Pressure ..........6tonne model no: ..............ls550v motor Power: ............3000W - 230V Tier log lengths ..........100 - 550mm overall (W x L x H): ......... 915 x 840 x 1495mm maximum log diameter ..........300mm...
  • Page 3 Factory set travel stops are positioned at the end of the control arm (fig.4.1). Arm travel can be adjusted if required by screwing the stops either in or out. fig.3 fig.5 fig.4 lS550V Issue 2 (2) 02/10/19 Original Language Version © Jack Sealey limited...
  • Page 4: Splitter Operation

    6.4.2. Adjust the log holders (fig.10.A) to suit the diameter of the log. This will allow the user to obtain the most comfortable angle for levers. Original Language Version lS550V Issue 2 (2) 02/10/19 © Jack Sealey limited...
  • Page 5: Maintenance

    7.1. cHecKing tHe oil 7.2. Check the oil level regularly as low oil levels can damage the pump. sealey hydraulic oil is available in 500ml containers (part no: HJO500MLS) or 5ltr containers (Part no: HJO5LS). 7.2.1. ensure the log splitter is disconnected from the mains power supply.
  • Page 6: Environment Protection

    Warranty: Guarantee is 12 months from purchase date, proof of which is required for any claim. Sealey Group, Kempson Way, Suffolk Business Park, Bury St Edmunds, Suffolk. IP32 7AR 01284 757500 01284 703534 sales@sealey.co.uk www.sealey.co.uk lS550V Issue 2 (2) 02/10/19 Original Language Version © Jack Sealey limited...