Page 1
THE AUTHORITY HAVING JURISDICTION (SUCH AS MUNICIPAL BUILDING DEPARTMENT, FIRE DEPARTMENT, FIRE PREVENTION BUREAU, ETC.) SHOULD BE CONSULTED BEFORE INSTALLATION TO DETERMINE ANY NEED TO OBTAIN A PERMIT. OBSERVE ALL LOCAL BUILDING CODES. Cleveland Ironworks a subsidiary of Enerco Group Inc. 4560 West 160th st Cleveland, Ohio 44135 1-800-251-0001...
ADDITIONAL MOBILE HOME REQUIREMENTS ......... 10 OPERATION ..................12 SMART STOVE WIFI CONNECTION ........... 14 WIFI CONTROLS ................15 PS60W, PS130W, AND PSBF66W MULTI FUNCTION CONTROLS ..16 MAINTENANCE .................17 WIRING DIAGRAM ................25 SERVICE PARTS ................26 Cleveland Iron Works Wood Pellet Fire Stove...
Electric Current During Lighting Phase [Amperes] Auger Motor R.P.M. This manual describes the installation and operation of the brand “Cleveland Ironworks” wood pellet fire stove. This stove meets the applicable U.S. Environmental Protection Agency’s emission limits for pellet fired heaters sold after 2020.
SAFETY PRECAUTIONS CARBON MONOXIDE HAVE AN ESTABLISHED PLAN FOR WHAT WARNING: TO DO IN THE EVENT OF A FIRE. CONTACT WHEN USED WITHOUT ADEQUATE YOUR LOCAL FIRE AUTHORITY TO ACQUIRE COMBUSTION AND VENTILATION AIR, THIS INFORMATION AND A PLAN FOR WHAT TO DO STOVE MAY GIVE OFF EXCESSIVE CARBON IN THE EVENT OF A CHIMNEY FIRE.
CLEARANCE TO COMBUSTIBLES • It has at least 2” (51 mm) of clearance from the The following stated clearances represent the minimum rear to the nearest body. distances between the stove and any other object. No • Vertical runs of vent pipe must be at least 3” (76 objects should encroach into this space.
Figure 4 Intake Kit 4. Some components are packaged unattached from Additional Assembly PS60W, PS130W the stove in order to ensure their safety during • The door handle: open the door, and screw the shipping. Please find the protective packaging, likely plastic grip onto the thread of the handle.
Page 7
If in doubt, it is of your stove, contact either: advisable to provide additional air. Outside combustion The manufacturer Cleveland Ironworks Company at air may be required if these or other indications 1-800-251-0001 • CLEVELAND-IRONWORKS.COM Our suggest that infiltration air is inadequate: office hours are 8:00 AM –...
Page 8
(ICBO) standards for solid fuel Stoves code- CONNECTOR REQUIREMENTS AND ASSEMBLY approved masonry chimney. CAUTION: A CHIMNEY CONNECTOR SHALL VENT TERMINATION NOT PASS THROUGH AN ATTIC OR ROOF • Install exhaust vent at clearances specified by the SPACE, CLOSET OR SIMILAR CONCEALED vent manufacturer.
Page 9
NFPA 211 (US ONLY) APPROVED WALL PASS THROUGH TECHNIQUES Figure 7 (US ONLY) Figure 9 (US ONLY) Brick Masonry: Minimum 3.5 inch (89 mm)thick brick Ventilated Thimble: Sheet steel chimney connector, masonry all framed into combustible wall with a minimum 24 gauge in thickness, with a ventilated minimum of 12 inch (305 mm) brick separation from thimble, minimum 24 gauge in thickness, having clay liner to combustibles.
ADDITIONAL MOBILE HOME REQUIREMENTS — The end of this duct must be equipped with a screen which prevents rodents from infiltrating. WARNING: DO NOT INSTALL IN SLEEPING — The end of this duct must be kept free of leaves, ROOM. snow, ice, or other debris that could restrict air supply when the appliance is in operation.
Page 11
LINED MASONRY CHIMNEY INSTRUCTIONS & DIAGRAM This stove is designed to be vented through a masonry chimney which conforms to local building codes, fire codes, and latest edition of NFPA 21 1 US or CAN/ CSA-B365. 1. If the connection piping from the stove to a masonry chimney is made through a combustible Wall Termination...
OPERATION bottom of the pellet container. THEORY OF OPERATION • Store pellets in sacks, made of environmentally 1. Combustion occurs in the fire pot, supported by neutral or biologically degradable plastic or from paper (2-3 layers / similar to cement packaging). air introduced to and under the fire pot.
Page 13
OPERATING PRECAUTIONS remenants out. • Feeding Cycle: Pellets will be transported from the WARNING: HOT WHILE IN OPERATION. DO Pellet Hopper into the fire pot by the auger. This NOT TOUCH THE STOVE. KEEP CHILDREN, can take 5 to 15 minutes depending on the model CLOTHING AND FURNITURE AWAY.
SMART STOVE WIFI CONNECTION See “MAINTENANCE” on page 17 for an explanation of Creosote formation and removal. To slow the build This stove can be monitored, controlled, and up of creosote within your chimney burn only the programmed by using the smart stove app by NHHATC recommended fuel, see page 12.
bottom of the app screen. Step 11. On your device, go to your device’s wifi settings which will now include the stove as an option. Select the stove as your wifi connection. Step 12. Open the Smart Stove phone app again. Step 13.
PS60W, PS130W, AND PSBF66W MULTI FUNCTION CONTROLS Manual / Automatic Wireless Connection Confirm Rate Select Notification Light Notification Light Up Selector MULTI FUNCTION DISPLAY Display Screen Settings Time Down Selector Power Figure 18a Mounted Multi Function Controls Panel Press to cycle between temperature reports...
MAINTENANCE CLEANING: GLASS This wood heater needs periodic inspection and repair WARNING: DO NOT CLEAN GLASS WHEN for proper operation. It is against federal regulations HOT. to operate this wood heater in a manner inconsistent Though the circulation of air across the glass reduces with operating instructions in this manual.
Page 18
Contact your local municipal or provincial fire authority for information PS130W PS60W, PSBF66W on how to handle a chimney fire. Have a clearly Figure 22 Convection Blower Disassembly understood plan to handle a chimney fire.
Page 19
WARNING: SUBSTITUTING ALTERNATE MATERIAL MAY SHATTER GLASS AND CAUSE INJURY. REPLACING: SEALING GASKETS Over time the sealing gaskets along the glass, door, or ash drawer may lose their rigidity. These seals are essential for providing a seal which allows the stove to operate safely.
Page 20
If a low pressure is created in the firebox by a leak, stove. opening the door to the firebox, a blocked flue, or • To remove the PS60W side panels, remove the an unsealed ash drawer then the switch will shut scews securing it on the rear of the heater. Then the stove off as a precaution.
Page 21
ERROR CODES NOTE: IN THE EVENT OF A POWER FAILURE (ERROR CODE E7), A SMALL AMOUNT OF SMOKE MAY BE EMITTED. THIS LASTS 3 TO 5 MINUTES AND DOES NOT REPRESENT A SAFETY RISK. CAUTION: IF OVERHEATING HAS OCCURRED (ERROR CODES E5 AND E6), THEN AN INSPECTION, MAINTENANCE, AND/OR CLEANING MUST OCCUR BEFORE THE STOVE CAN SAFELY BE OPERATED AGAIN.
Page 22
ERROR CODES CONTINUED 1. Check wires and connection points. ESO2 Open circuit at temperature sensor #2 2. Replace Motherboard. 1. Check wires and connection points. ESC3 Short circuit at temperature sensor #3 2. Replace Motherboard. 1. Check wires and connection points. ESO3 Open circuit at temperature sensor #3 2.
Page 23
TROUBLESHOOTING CONTINUED SYMPTOM CAUSE SOLUTION Too much fuel in the The feeding speed 1. Increase the fan’s speed to increase the rate of firepot. The fuel can not be is faster than what combustion. completely and thoroughly combustion can 2. Reduce the feeding speed. burned.
Page 24
TROUBLESHOOTING CONTINUED SYMPTOM CAUSE SOLUTION No fuel in Pellet Add Fuel to Pellet Hopper. Hopper. 1. Unplug the unit so that it will not start suddenly and then unblock the auger. Auger is blocked 2. Check that the auger is not blocked. If it is blocked, or jammed or remove the cause of the jamming.
WIRING DIAGRAM NOTE: IF ANY OF THE ORIGINAL WIRE AS SUPPLIED WITH THE APPLIANCE MUST BE REPLACED, IT MUST BE REPLACED WITH WIRING MATERIAL HAVING A TEMPERATURE RATING OF AT LEAST 105 °C AND RATED FOR 600V Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 26
Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
Page 27
Cleveland Iron Works Wood Pellet Fire Stove Operating Instructions and Owner’s Manual...
SERVICE PARTS MODEL PSBF66W NOTE: NOT ALL PARTS AVAILABLE. FOR QUESTIONS CONTACT MANUFACTURER. WARNING: FAILURE TO POSITION THE PARTS IN ACCORDANCE WITH THESE DIAGRAMS OR FAILURE TO USE ONLY PARTS SPECIFICALLY APPROVED WITH THIS STOVE MAY RESULT IN PROPERTY DESCRIPTION DESCRIPTION DAMAGE OR PERSONAL INJURY.
Page 29
This Warranty gives you specific legal rights, and you may have other rights which vary from state to state. Cleveland Ironworks Inc. reserves the right to make changes at any time, without notice or obligation, in colors, specifications, accessories, materials and models.
Page 30
POUR DÉTERMINER VOTRE BESOIN DE PERMIS, CONSULTEZ LES AUTORITÉS AYANT JURIDICTIONS DANS VOTRE LOCALITÉ (AUTORITÉS DE PRÉVENTION DES INCENDIES, SERVICE DE LA CONSTRUCTION MUNICIPAL, ETC.). RESPECTEZ TOUS LES CODES DE LA CONSTRUCTIONS LOCAUX. Cleveland Ironworks une filiale de Enerco Group Inc. 4560 West 160th st Cleveland, Ohio 44135 1-800-251-0001...
Page 31
EXIGENCES SUPPLÉMENTAIRES POUR LES MAISONS MOBILES ..10 FONCTIONNEMENT ................12 CONNEXION WI-FI « SMART STOVE » ..........14 COMMANDES WI-FI ................15 COMMANDES MULTIFONCTIONS PS60W, PS130W ET PSBF66W ..16 ENTRETIEN ..................17 SCHÉMA DE CÂBLAGE ..............25 PIÈCES DE SERVICE ................26 Cleveland Iron Works Poêle à...
Le présent manuel décrit la procédure d’installation et de fonctionnement des poêles à grenailles de bois Cleveland Ironworks. Votre poêle est conforme aux limites d’émission de l’EPA (Environmental Protection Agency) des États-Unis pour les poêles à grenailles fabriqués après l’année 2020.
PRÉCAUTIONS DE SÉCURITÉ MONOXYDE DE CARBONE ÉTABLISSEZ UNE RÉACTION DE SURVIE EN AVERTISSEMENT : CAS D’INCENDDIE. COMMUNIQUEZ AVEC LE SI UTILISÉ SANS COMBUSTIBLE ET AÉRATION SERVICE D’INCENDIE LOCAL POUR OBTENIR DES ADÉQUATS, CE POÊLE PEUT PRODUIRE UN RENSEIGNEMENTS ET UNE PROCÉDURE D’ACTIONS À EXCÈS DE MONOXYDE DE CARBONE, UN GAZ PRENDRE EN CAS DE FEU DE CHEMINÉE.
DISTANCES DE DÉGAGEMENT DES • Qu’il y ait un dégagement minimum de 330 mm (13 po) de chaque coté de l’appareil. MATÉRIAUX COMBUSTIBLES • Qu’il y ait un dégagement minimum de 51 mm (2 po) à Les distances de dégagement indiquées ci-dessous l’arrière de l’appareil.
Trousse d’entrée ENDOMMAGÉS. 4. Pour assurer la sécurité de certaines pièces délicates, Assemblage supplémentaire PS60W, PS130W celles-ci sont emballées séparément. Veuillez les localiser, • Poignée de porte : ouvrez la porte et vissez l’emprise vraisemblablement à l’intérieur de l’appareil pour plastifiée dans les filets de la...
Page 36
être requis si les indications ci-dessous, ou d’autres indications, votre poêle, veuillez contacter soit : suggèrent que l’apport d’air est insuffisant : Le fabricant Cleveland Ironworks Company à 1-800-251-0001 • Le poêle à grenailles de bois n’aspire pas de façon constante et produit des bouffées de fumée, les grenailles...
Page 37
Conference of Building Officials) pour les poêles à ATTENTION : LE TUYAU DE RACCORDEMENT DE combustible solide. CHEMINÉE NE DOIT PAS TRAVERSER LE GRENIER CAPUCHON D’ÉVENT OU LE TOIT, OU TOUT GARDE-ROBE OU ARMOIRE • Installer l’évent d’échappement en respectant les distances (OU AUTRE ESPACE CLOS) NI LE PLANCHER OU LE de dégagement spécifiées par le fabricant.
Page 38
TECHNIQUES DE TRAVERSÉE DE MUR APPROUVÉES NFPA 211 (É-U SEULEMENT) Dégagement de cheminée minimum NFPA 211 (É-U SEULEMENT) Dégagement minimum de la cheminée des surfaces aux montants de soutien en acier et des de brique ou de matériau combustible : 51 mm (2 po) matériaux combustibles : 51 mm (2 po) Gaine à...
EXIGENCES SUPPLÉMENTAIRES POUR MAISONS compromettant une aération adéquate. • Une canalisation permanente d’admission d’air frais MOBILES pour entretenir la combustion devra être installée en répondant aux exigences suivantes : AVERTISSEMENT : NE PAS LOCALISER DANS — La canalisation devra être totalement métallique LES CHAMBRES À...
Page 40
INSTRUCTIONS ET SCHÉMA DE CHEMINÉE DE MAÇONNERIE AVEC CONDUIT DE FUMÉE Ce poêle est conçu pour une évacuation par une cheminée de maçonnerie conforme au code du bâtiment et code des incendies locaux ainsi qu’aux dernières éditions des normes NFPA 211 aux États-Unis ou CSA-B365 au Canada. 1.
FONCTIONNEMENT • Ne pas utiliser les sédiments et débris au fond des contenants de grenailles. THÉORIE DE FONCTIONNEMENT 1. La combustion se produit dans le pot du poêle qui • Entreposer les grenailles dans des sacs à deux ou trois couches de papier (comme ceux des sacs de ciment) ou est alimenté...
Page 42
PRÉCAUTIONS POUR LE FONCTIONNEMENT • Cycle de nettoyage : Le pot de combustion est nettoyé des cendres, poussières et résidus accumulés. AVERTISSEMENT : BRÛLANT DURANT LE • Cycle d’alimentation : Les grenailles passeront de la FONCTIONNEMENT. NE PAS TOUCHER.LE trémie au pot de combustion par l’entremise de la POÊLE.
CONNEXION WI-FI « SMART STOVE » qu’elles correspondent aux exigences de votre poêle telles qu’indiquées à la page 3. L’état de votre poêle peut être surveillé, contrôlé et programmé en utilisant l’application Smart Stove. (par COMMENT MINIMISER LA FORMATION DE CRÉOSOTE NHHATC) qui est disponible à...
poêle comme un des choix. Sélectionnez le poêle comme votre connexion wi-fi. Étape 12. Ouvrez à nouveau l’application Smart Stove sur votre téléphone. Étape 13. Vous pouvez maintenant sélectionner ce poêle à partir de la liste des dispositifs ajoutés pour programmer, commander et surveiller le fonctionnement du poêle.
Page 45
COMMANDES MULTI-FONCTIONS POUR PS60W, PS130W ET PSBF66W Témoin d’avis Manuel/Automatique Témoin d’avis de connexion Sélecteur Confirmer Sélection de taux Wi-Fi d’accroissement MULTI FUNCTION DISPLAY Afficheur Paramètres Minuterie Sélecteur de décroissement Alimentation Figure 18a Panneau multi-fonction monté Actionner pour faire défiler les lectures de Alimentation température (en °...
ENTRETIEN NETTOYAGE : VITRE Pour un bon rendement de fonctionnement ce poêle à AVERTISSEMENT : NE PAS NETTOYER LA grenailles de bois nécessite un entretien périodique. Toute VITRE LORSQUE CHAUDE. opération ne respectant pas les directives du présent Guide Bien que la circulation d’air sur la porte vitrée réduit du propriétaire contrevient à...
Page 47
être requis alors qu’en chauffage plus élevé durant l’hiver un nettoyage mensuel PS130W PS60W, PSBF66W pourrait suffire. Pour apprendre comment traiter un feu de Figure 22 Démontage du ventilateur de cheminée, communiquez avec les autorités ou le service convection d’incendie de votre localité.
Page 48
REMPLACEMENTS : SYSTÈME DE TARIÈRE AVERTISSEMENT : L’UTILISATION DE MATÉRIAU SUBSTITUT POURRAIT BRISER LA VITRE ET CAUSER DES BLESSURES. R EMPLACEMENTS : JOINTS D’ÉTANCHÉITÉ Au fil du temps, les joints d’étanchéité autour de la vitre, de la porte et du tiroir de cendre pourraient perdre de leur rigidité.
Page 49
• Pour retirer les panneaux latéraux du modèle combustion, une cheminée obstruée ou un tiroir de PS60W, retirer les vis de fixation à l’arrière de cendre non scellé, le pressostat éteindra le poêle comme l’unité et retirer directement le panneau.
Page 50
CODES D’ERREUR REMARQUE :DANS L’ÉVENTUALITÉ D’UNE PANNE DE COURANT (CODE D’ERREUR E7), UNE FAIBLE QUANTITÉ DE FUMÉE POUR- RAIT ÊTRE DÉGAGÉE. CECI DURERA DE TROIS À CINQ MINUTES ET NE REPRÉSENTE PAS UN DANGER. ATTENTION : S’IL S’EST PRODUIT UNE SURCHAUFFE (CODES D’ERREUR E5 ET E6), ALORS UNE INSPECTION, ENTRETIEN ET/OU UN NETTOYAGE DEVRA ÊTRE EFFECTUÉ...
Page 51
CODES D’ERREUR (SUITE) Capteur de température n 1. Vérifier les fils et les points de raccordement. ESO3 en circuit ouvert 2. Remplacer la carte mère. DÉPANNAGE SYMPTÔME CAUSE SOLUTION Le commutateur d’alimentation n’est Actionner le commutateur d’alimentation. pas fermé. 1. Insérer à fond le cordon d’alimentation dans le Le cordon poêle Le poêle ne s’allume pas.
Page 52
DÉPANNAGE (SUITE) SYMPTÔME CAUSE SOLUTION La vitesse Trop de grenailles dans le pot d’alimentation 1. Augmenter la vitesse du ventilateur pour de combustion. Les grenailles est plus grande augmenter le taux de combustion. ne se consomment pas que la capacité de 2.
Page 53
DÉPANNAGE (SUITE) SYMPTÔME CAUSE SOLUTION La trémie est vide. Ajouter des grenailles dans la trémie. 1. Débrancher l’unité de sorte qu’il ne se produise pas de démarrage inattendu et dégager le blocage de la tarière. La tarière est 2. Vérifier que la tarière ne soit pas bloquée. Si c’est le cas, coincée, obstruée ou dégager le produit causant le coincement.
SCHÉMA DE CÂBLAGE REMARQUE : SI DES FILS QUELCONQUES DOIVENT ÊTRE REMPLACÉS ILS DEVRONT CORRESPONDRE AUX SPÉCIFICATIONS DE CÂBLAGE ORIGINAL DE TEMPÉRATURE NOMINALE DE 105 °C AVEC ISOLANT DE CLASSE DE 600 V Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
Page 55
Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
Page 56
Cleveland Iron Works Poêle à grenailles de bois Guide du propriétaire et intructions d’utlisation...
PIÈCES DE SERVICE MODÈLE PSBF66W REMARQUE : LES PIÈCES NE SONT PAS TOUTES EN MAGASIN. POUR TOUTE QUESTION, COMMUNIQUEZ AVEC LE FABRICANT. AVERTISSEMENT : NE PAS POSITIONNER LES PIÈCES SELON CES SCHÉMAS OU NE PAS UTILISER EXCLUSIVEMENT LES PIÈCES SPÉCIFIQUEMENT APPROUVÉES POUR CE POÊLE POURRAIT RÉSULTER EN DES DOMMAGES MATÉRIELS OU DES BLESSURES AUX OCCUPANTS.
Page 58
Si une pièce est endommagée ou manquante, appelez notre Service de soutien technique au 1-800-251-0001. Adresser toute demande de compensation de garantie à : Service Department, Cleveland Ironworks, Inc., 4560 W. 160TH ST., CLEVELAND, OHIO 44135 U.S.A. Indiquez votre nom, adresse et numéro de téléphone, le numéro de modèle et le numéro de série de votre produit et décrivez les détails concernant la demande de compensation.
Need help?
Do you have a question about the PS60W and is the answer not in the manual?