Digital Equipment EtherWORKS ISA PnP 10 Installation And Configuration Manual

Advertisement

Quick Links

EtherWORKS ISA
PnP 10
Installation and
Configuration
Part Number: EK-DE305-IN. A01
Revision/Update Information:
This is a new manual.
Digital Equipment Corporation
Maynard, Massachusetts

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the EtherWORKS ISA PnP 10 and is the answer not in the manual?

Questions and answers

Summary of Contents for Digital Equipment EtherWORKS ISA PnP 10

  • Page 1 EtherWORKS ISA PnP 10 Installation and Configuration Part Number: EK-DE305-IN. A01 Revision/Update Information: This is a new manual. Digital Equipment Corporation Maynard, Massachusetts...
  • Page 2 December 1996 Digital Equipment Corporation makes no representations that the use of its products in the manner described in this publication will not infringe on existing or future patent rights, nor do the descriptions contained in this publication imply the granting of licenses to make, use, or sell equipment or software in accordance with the description.
  • Page 3 FCC Class B Certification FCC ID: HEDEN1660 This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential installation.
  • Page 4: Table Of Contents

    Conventions....................ix Package Contents..................x Quick Installation ..................xi MPX Link for Novell NetWare..............xii 1 Introduction Overview ....................1–1 EtherWorks ISA PnP 10 Adapter ...............1–1 Features .....................1–2 2 Hardware Installation and Configuration Overview ....................2–1 Hardware Features ..................2–1 Connectors..................2–2 LEDs ....................2–3 Hardware Installation.................2–3...
  • Page 5 Connecting to a Ethernet Network Using AUI ........2–8 Connecting to a ThinWire Ethernet Network ........2–9 3 Diagnostics and Software Installation Overview....................3–1 Diagnostics ....................3–1 Adapter Diagnostics................3–1 EEPROM Diagnostics.................3–3 Network Diagnostics................3–3 Software Information.................3–3 Software Installation..................3–4 Menu Bar Options................3–4 Menu Selections .................3–5 A Troubleshooting Overview....................
  • Page 6 C Plug and Play Systems Overview ....................C–1 Plug and Play Characteristics..............C–1 Glossary...
  • Page 7: Before You Start

    Before You Start Overview This guide explains how to install and configure the EtherWORKS ISA PnP 10 adapter (also referred to as the DE305 or adapter). The adapter uses the 1Step Installation utility (also referred to as 1Step) for hardware configuration, software installation, and diagnostics.
  • Page 8: Package Contents

    Before You Start Package Contents The EtherWORKS ISA PnP 10 package contains the items in the following list and shown in the following figure: ™ • The EtherWORKS ISA PnP 10 adapter š • Antistatic packaging › î • -inch distribution diskette œ...
  • Page 9: Quick Installation

    Before You Start Quick Installation The DE305 distribution diskette contains the menu-driven 1Step Installation utility that provides quick adapter hardware configuration, software installation, and diagnostics for NetWare and non-NetWare operating systems. (See the Hardware Configuration section in Chapter 2 for more information.) To install the DE305 adapter and the 1Step utility, use the following procedure: 1.
  • Page 10: Mpx Link For Novell Netware

    Before You Start MPX Link for Novell NetWare As an alternative to the previous procedure, you can use the MPX Link option from the 1Step main screen to automatically log on to the Novell NetWare network using the adapter’s current I/O base address and IRQ setting. The 1Step utility will copy the appropriate drivers onto your hard disk, create the necessary configuration files, initialize the network drivers, and log on to the nearest NetWare server.
  • Page 11: Introduction

    Introduction Overview This chapter describes the EtherWORKS ISA PnP 10 adapter and lists the adapter’s features. EtherWORKS ISA PnP 10 Adapter The DE305 adapter is a 16-bit network interface card (NIC) developed for ISA bus computers. The adapter provides twisted-pair, thickwire AUI, and ThinWire BNC connectors that support industry standard Plug and Play technology (see Appendix C for more information about Plug and Play).
  • Page 12: Features

    Introduction Features The main features of the DE305 are as follows: • Plug and Play technology • 1Step utility program to configure and diagnose your network • Supports full-duplex Ethernet operation to increase bandwidth to 20 Mb/s • Conforms to IEEE 802.2, IEEE 802.3, 10 Mb/s, and ISO 8802.3 standards •...
  • Page 13: Hardware Installation And Configuration

    Hardware Installation and Configuration Overview This chapter describes the hardware features of the EtherWORKS ISA PnP 10 adapter, how to install the adapter in your computer, how to connect the adapter to the network, and how to configure the adapter.
  • Page 14: Connectors

    Hardware Installation and Configuration Connectors ™ The DE305 contains a 10BaseT 8-pin MJ twisted-pair (TP) connector š a 10Base5 AUI thickwire connector , and a 10Base2 ThinWire BNC › connector DE305-AA LJ-5232.AI4 2–2...
  • Page 15: Leds

    Hardware Installation and Configuration LEDs œ The link LED (LNK ) lights when a valid link pulse is established during normal operation. If no data or link pulses are detected, the LED does not light, indicating a failed status (refer to Appendix A for troubleshooting information). ___________________________Note _____________________ The link LED is insensitive to the status of AUI or BNC connections.
  • Page 16 Hardware Installation and Configuration 7. Insert the adapter into the slot, then replace the screw to secure the adapter (see the following figure). LJ-5233.AI4 8. Replace the computer cover, then reconnect the cables. 9. Connect the adapter to the network (see the Connecting to the Ethernet Network section in this chapter).
  • Page 17: Hardware Configuration

    Hardware Installation and Configuration Hardware Configuration After you have installed the adapter, use the following procedure to install the 1Step utility: 1. Insert the distribution diskette into the diskette drive on the host PC (for example, drive A), enter the following command, then press Enter: C:>...
  • Page 18 Hardware Installation and Configuration 3. Select the View Current Configuration option from the 1Step Main Menu. Main Menu View Current Configuration Default Setup Manual Setup Diagnose The Adapter Diagnose EEPROM Run Diagnostics on NetWork Exit SETUP LJ-5243.AI4 4. Verify the hardware settings shown on the Current Configuration screen, then press Esc to return to the Main Menu.
  • Page 19 Hardware Installation and Configuration Select the Manual Setup option to configure the adapter with your own settings. Manual Setup Menu Operating Mode: Plug & Play Medium Type: Auto Detect Full-duplex: Disabled Boot ROM: Disabled Power-up I/O : Power-up IRQ : Power-up Status : LJ-5246.AI4 To select a suitable configuration, specify the following:...
  • Page 20: Optional Remote Boot Rom

    Hardware Installation and Configuration Optional Remote Boot ROM The DE305 contains a socket for installing an optional 16 KB remote boot ROM. Installing a ROM allows the adapter to be used for diskless operation by permitting the host PC to load the operating system over the network. To install the remote boot ROM, use the following procedure: 1.
  • Page 21: Connecting To A Thinwire Ethernet Network

    Hardware Installation and Configuration Connecting to a ThinWire Ethernet Network › To connect the DE305 to a ThinWire network 1. Attach the ThinWire cables to a T-connector. 2. If the system is at the end of an Ethernet segment, attach a terminator to the unused side of the T-connector.
  • Page 22: Diagnostics And Software Installation

    Diagnostics and Software Installation Overview This chapter describes how to use the 1Step utility for diagnostics and software installation. Diagnostics When hardware installation is complete, run the 1Step diagnostics to test the DE305 components and installation. Adapter Diagnostics Select the Diagnose the Adapter option from the 1Step Main Menu to test the adapter and the corresponding cabling.
  • Page 23 Diagnostics and Software Installation When you run these diagnostics, the screen displays the Pass or Fail count for each test. If a test fails, press the space bar to display the reason for failure and possible solutions. The following adapter diagnostics are run: Configuration Test to check the initial status of the adapter I/O Registers Test to check I/O accessibility Internal Loopback Test to check the adapter’s controller...
  • Page 24: Eeprom Diagnostics

    Initiator displays the current Responder and the status of corresponding communications. Software Information The EtherWORKS ISA PnP 10 distribution diskette contains device driver software and installation information. If your network operating system runs under DOS, use 1Step to install the corresponding driver. The RELEASE.TXT file located in the diskette’s root directory provides information about the...
  • Page 25: Software Installation

    Diagnostics and Software Installation Software Installation Select the Software Installation option from the 1Step main screen to display the Software Installation menu (shown in the following figure). This menu is used to select the appropriate software vendor, network operating system, driver, and frame type (for Novell software), and the directory in which the drivers are to be stored.
  • Page 26: Menu Selections

    Diagnostics and Software Installation Select the menu bar submenu items to perform the following functions: • File — Open a DOS shell or exit to the 1Step main screen. • Action — Install the selected software or update the specified drivers. These functions can be performed also by pressing the F2 and F3 keys respectively.
  • Page 27: Overview

    Troubleshooting Overview The 1Step utility used by the EtherWORKS ISA PnP 10 adapter includes a diagnostics program for checking the adapter components and the network cabling. The adapter may fail some tests for reasons that may be easily remedied by the user. This appendix describes common problems you may encounter and possible solutions.
  • Page 28: Diagnostic Test Errors

    Troubleshooting Diagnostic Test Errors The following table describes the common diagnostic errors and the recommended corrective actions: Symptom Possible Cause Recommended Actions The LNK LED does not light Invalid TP link. Check the 8-pin MJ connection for loose cabling. after making a TP connection. Check for incorrect pin assignments.
  • Page 29: Cabling

    Troubleshooting Refer to the diagnostic section in Chapter 3 to verify that all other system components are functioning properly. If any component fails the diagnostic test, contact your Digital Services Representative. Cabling Verify the DE305 cabling as follows: 1. Check that you are using the correct cable type. Be sure that the cable connector is securely seated in the port.
  • Page 30: B General Information

    General Information Overview This appendix provides the following general information for the EtherWORKS ISA PnP 10 adapter: • Physical characteristics • Regulatory standards compliance • Operating environment and power requirements • Connector pin assignments Conformance The DE305 conforms to the following IEEE standards and media-supported specifications: •...
  • Page 31: System Configuration Specifications

    General Information System Configuration Specifications The following table lists the system configuration specifications for the DE305: Transmission technique Baseband Topology Star/Bus Access method CSMA/CD Transmission rate 10 Mb/s End user devices supported IBM PC-XT, AT, 286, 386, 486, Pentium, PS/2 Model 30, compatible ISA bus computers I/O base address 0200H to 03E0H...
  • Page 32: Operating Environment Specifications

    General Information Operating Environment Specifications The following table lists the operating environment and power requirements for the DE305: Specification Rating Operating temperature (sea level) 0°C to 55°C (32°F to 131°F) standard operating Relative humidity 10% to 90% (noncondensing) Radiated emissions FCC Class B, CISPR 22 Class B VCCI Class 2...
  • Page 33: Connector Pin Assignments

    General Information Connector Pin Assignments This section describes the DE305 connector pin assignments. 8-Pin MJ Port The DE305 twisted-pair network connector pin signals are shown in the following figure and explained in the following table: LJ-4797.AI4 Assignment Output Transmit Data+ Output Transmit Data–...
  • Page 34: Aui Port

    7, 8, 15 No connection Other Digital Network Products The EtherWORKS ISA PnP 10 adapter is part of a complete family of low-cost network switches, adapters, and boot ROMs developed by Digital Equipment Corporation. Other products are listed in the following table.
  • Page 35 General Information Product Order Number Description Fast EtherWORKS PCI DE500-AA Provides a single 10 Mb/s or 100 Mb/s 8-pin MJ port to connect to 10/100 Adapter IEEE 802.3 Ethernet networks. EtherWORKS Switch DEL8X-AA Provides eight 10 Mb/s or 100 Mb/s 8-pin MJ ports to connect to 8T/TX (U.S., Japan, IEEE 802.3 standard or Fast Ethernet networks.
  • Page 36: Ordering Information

    General Information Ordering Information To order these products, contact an Authorized Digital Distributor or Digital sales representative. For more information, call 800–457–8211 in the U.S. and Canada, 508–692–2562 in other locations, or your local sales office. B–7...
  • Page 37 Plug and Play Systems Overview This appendix describes briefly the Plug and Play design philosophy that is based on a set of open specifications for PC architecture. The ultimate goal of Plug and Play is to design enough intelligence into the PC to handle installation and configuration tasks without user intervention.
  • Page 38 Glossary 1Step The specialized installation utility used with the DE305 for quick adapter hardware and software installation and diagnostics. 8-pin MJ connector Most common terminator for twisted-pair wiring. 10Base2 IEEE specifications for running 10 Mb/s Ethernet using ThinWire coaxial cable. A cable segment can be up to 185 meters long and have a maximum of 30 nodes.
  • Page 39 Glossary Attachment Unit Interface (AUI) A 15-pin logical, electrical, and mechanical interface specified by the IEEE 802.3 standard for connecting a PC, server, workstation, or other device to a thickwire Ethernet backbone. This port can be connected to a variety of Ethernet media (including BNC or fiber-optic) using an Ethernet transceiver or Media Access Unit (MAU).
  • Page 40 Glossary CSMA/CD Carrier send multiple access with collision detection. This is a medium access control technique for bus-tree topologies. driver Program that enables the network operating system to communicate with LAN network interface cards. Ethernet A network communication system developed and standardized by Digital, Intel, and Xerox, using baseband transmission, CSMA/CD access, logical bus topology, and coaxial cable.
  • Page 41 Glossary loopback Diagnostic test in which a signal is transmitted across a medium while the sending device waits for its return. local area network (LAN) A group of interconnected computers and support devices. NetWare The Novell network operating system that provides the ability to transparently share services across dissimilar platforms.

Table of Contents