Replacing Flowire Converter FCDC1/FCDC2
Item Number
Item Name
100 8080 110
FCDC1
100 8080 210
FCDC2
See A100K11422 Flowire Converter Configuration Manual for further information.
Pressing and holding the Password Reset Button for more than 15 seconds will reset
the NMK password to the default: HomePlugAV0123
1

Demounting the Old Flowire Converter

To demount the Flowire Converter:
1. Disconnect the Flowire Converter from the power supply, ground wire, and network.
2. Pry the mounting clips loose from the DIN rail of the rack to release the Flowire Converter.
2

Mounting the New Flowire Converter

To mount the Flowire Converter:
1. Press the Flowire Converter against the DIN rail of the rack until the mounting clips snap into
place.
2. Reconnect the Flowire Converter to the power supply, ground wire, and network.
Description
Flowire Converter 24-48VDC with power-forwarding (PoE, type 2)
Flowire Converter 24VDC non-PoE

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FCDC1 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Vingtor Stentofon FCDC1

  • Page 1 Replacing Flowire Converter FCDC1/FCDC2 Item Number Item Name Description 100 8080 110 FCDC1 Flowire Converter 24-48VDC with power-forwarding (PoE, type 2) 100 8080 210 FCDC2 Flowire Converter 24VDC non-PoE See A100K11422 Flowire Converter Configuration Manual for further information. Pressing and holding the Password Reset Button for more than 15 seconds will reset...
  • Page 2 2. Access the Flowire Converter with the default IP address 169.254.1.10 via a web browser  FCDC1 has PoE injected on the spare pairs in the network port, so either use an Ethernet cable where these signals are disconnected or a PC which can handle this.
  • Page 3 3.3 Change Network Management Key (NMK) NMK should be changed to one specified for the project. This will ensure that the Flowire Converter can communicate with a Flowire Converter at the other end of the Flowire line. Two Flowire Converters connected together require the same NMK to communicate.

This manual is also suitable for:

Fcdc2

Table of Contents