Floor distributor

Advertisement

User Manual
FLOOR DISTRIBUTOR CCU-FS
• Thank you for purchasing COMMAX products.
• Thank you for purchasing COMMAX products.
• Please carefully read this User's Guide (in particular, precautions for safety) before using a product and follow
• Please carefully read this User's Guide (in particular, precautions for safety) before using a product and follow
instructions to use a product exactly.
instructions to use a product exactly.
• The company is not responsible for any safety accidents caused by abnormal operation of the product.
• The company is not responsible for any safety accidents caused by abnormal operation of the product.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CCU-FS and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Commax CCU-FS

  • Page 1 User Manual FLOOR DISTRIBUTOR CCU-FS • Thank you for purchasing COMMAX products. • Thank you for purchasing COMMAX products. • Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow • Please carefully read this User’s Guide (in particular, precautions for safety) before using a product and follow instructions to use a product exactly.
  • Page 2: Table Of Contents

    Floor Distributor Power Using a Separate Power Supply System power diagram System Diagram and wiring CCU-FS Wiring method and the role of each connector UTP CABLE wiring UTP CABLE Configuration between a Multi-Entry Panel and a Building Distributor CABLE Configuration between...
  • Page 3: Warnings And Caution

    Warnings and caution Make sure to follow the instructions to prevent any danger or property losses. It indicates prohibition. It indicates prohibition of disassembly. Warning Death or serious It indicates prohibition of contact. injury is expected. It indicates dos and don’ts. It indicates that the plug should be pulled out from the socket.
  • Page 4 Install the product in a flat and Pull the plug if the product is If the product generates strange stable place. not used for a long time. sound, make sure to pull the Otherwise, it may not function plug immediately and contact properly. Commax service center.
  • Page 5: Application

    To Building distributor : 8-wire (talk2, Data1, VCC, Video, GND) Wiring To In-house Unit : 6-wire(talk 2, Data1, VCC, Video, GND) Power voltage 28V/5A CCU-FS With 1 residence unit PowerCCU-FS Standby : 200m Requirements Maximum operation: 510mA Installation Range : Per floor 4 meters / Maximum 50 floors;...
  • Page 6: Floor Distributor Power

    ♠ ♠ Floor Distributor Power When using DC28V/ 5A power, one power supply can cover up to 8 floor distributors (32 housing units) when connecting 1 in-house-unit per residence. The diagram below displays the maximum capability for one power supply coverage. - 8P(Conversotion2, DATA2, VIDEO POWER GROUND) - 6P(Conversotion2, DATA, VIDEO POWER GROUND) The first power supply should be powered with the 3rd floor distributor unit (28V/5A).
  • Page 7: System Power Diagram

    ♠ ♠ System power diagram (When one power supply cover up to 8 floor distributors)
  • Page 8 - The picture above shows the maximum power one building distributor can cover. This supports for stable power distribution to run. it is highly recommended to install the power supply to the 3rd floor distributor to ① provide ample power between the floor 1 through floor 8 distributors. Power source: (DC28V/5A) The following wiring is recommended for stable power supply and to prevent ②...
  • Page 9: System Diagram And Wiring

    - Disconnect from the 32th floor distributor OUT-terminal to 7th wire(+28V VCC) in the 33th floor distributor IN-terminal, because the 28rd floor distributor power supply (28V/5A) will be transmitted to each floor distributors from floors 24 through 31 - Disconnect from the 40th floor distributor OUT-terminal to 7th wire(+28V VCC) in the 41th floor distributor IN-terminal, because the 36rd floor distributor power supply (28V/5A) will be transmitted to each floor distributors from floors 32 through 40.
  • Page 10: Ccu-Fs Wiring Method And The Role Of Each Connector

    ♠ ♠ CCU-FS Wiring method and the role of each connector CN1 : Connect to 1st in-house unit with 6 wires ● (talk 2, Data 1, Power 1, Video 1, GND 1) CN2 : Connect to 2nd in-house unit with 6 wires ●...
  • Page 11: Utp Cable Wiring

    4. UTP CABLE wiring In this system, the multi-entry panel units use one UTP cable to transmit the DATA, TALK, VIDEO, POWER to all household units . The diagram below details the most effective wiring method to transm it DATA, TALK, VIDEO, POWER between all system units. If the wiring sequences below are not carefully followed, the clearest audio and video quality cannot be guaranteed.
  • Page 12: Cable Configuration Between A Building Distributor And A Floor Distributor

    ♠ ♠ CABLE Configuration between a Building Distributor and a Floor Distributor 1,2 wires – TALK/ 3,4 wires – DATA/ 5,6 wires – VIDEO/ 7,8 wires – POWER & GND ♠ ♠ UTP Configuration between a Floor Distributor and House Units 1,2 wires –...
  • Page 13 Memo...
  • Page 14 513-11, Sangdaewon-dong, Jungwon-gu, Seongnam-si, Gyeonggi-do, Korea Int’l Business Dept. Tel. : +82-31-7393-540~550 Fax. : +82-31-745-2133 Web site : www.commax.com PM32FS000010 Printed In Korea / 2011.03.104...