PTZ-900 ™ 900MHz Spread-Spectrum Digital Wireless Pan/Tilt/Zoom Camera Control Transmission System Installation and Operating Instructions THE LEADER IN WIRELESS VIDEO...
Page 2
If it is not 9600 bps and RS485/422, you will need either to change the setting of the PTZ controller and receiver/driver or to change the settings of the PTZ-900 equipment. See the end of this manual for information on changing PTZ-900 internal settings using TrangoLink software.
90° from its normal position. ¢ Most common connection diagram for setting up a PTZ link using the PTZ-900-N system. The dome shown may instead be a standard receiver/driver unit with a separate PTZ base.
NEMA 4× aluminum enclosure. This permits the unit to be mounted outdoors. PTZ-900 Installation and Operating Instructions Important! The PTZ-900 enclosures are designed for a steel pole with a maximum diameter of 2 be securely mounted into the ground or to a structure to prevent move- ment of the antenna and camera in windy conditions.
PTZ-900 Installation and Operating Instructions TX RX The front panel of the PTZ-900 transmitter. Power input. Accepts a power source between 6 and 13 volts DC. It is highly recommended that the supplied power adapters (7VDC) be used to reduce the heat dissipated from the unit.
95 or higher and connects from either COM1 or COM2 to the data inter- face on the transmitter or receiver via the CBLDAT-2 interface cable. To enter the program, the user must apply power to the PTZ-900 unit and, within twenty seconds, run the TrangoLink program by clicking receiver.
(dBm) against frequency (MHz). Useful in trouble- shooting to determine if any other signals are present in the 900MHz band. Meaningless if connected to the PTZ-900 Data Rate. The rate for PTZ data can be set between 1200 and 19200 bps.
Page 8
TrangoLink program from Windows. The LED will alternate between green and red to indicate that it is ready to talk to the TrangoLink software. Important! Do not use any other cable for this purpose. PTZ-900 Installation and Operating Instructions Parametric Specifications PTZ-900 Transmitter: Electrical...
Page 9
100% condensing when installed properly The receiver complies with FCC Part Shock: 15.299 and FCC Part 15.207(a) Trango Systems technical support online: www.trangosys.com voice: +1 858-653-3900 PTZ-900 Installation and Operating Instructions 48 bytes software-selectable 1200, 2400, 4800, balanced 6–13VDC two-position terminal block –20ºC to 70ºC...
Need help?
Do you have a question about the PTZ-900 and is the answer not in the manual?
Questions and answers