Page 4
Quoting of brand and product names is for information purposes only and does not represent trademark misuse. The information in this document is subject to change without notice. Bull will not be liable for errors contained herein, or for incidental or consequential damages in connection with the use of this material.
Safety notices ....... . . v Service information for the 58/88 or ED/R1 PCIe storage enclosure ..1 58/88 or ED/R1 PCIe storage enclosure service overview .
Page 6
Power systems: Service procedures for the PCIe storage enclosure...
Safety notices Safety notices may be printed throughout this guide. v DANGER notices call attention to a situation that is potentially lethal or extremely hazardous to people. v CAUTION notices call attention to a situation that is potentially hazardous to people because of some existing condition.
Page 8
DANGER When working on or around the system, observe the following precautions: Electrical voltage and current from power, telephone, and communication cables are hazardous. To avoid a shock hazard: v Connect power to this unit only with the provided power cord. Do not use the provided power cord for any other product.
Page 9
Observe the following precautions when working on or around your IT rack system: v Heavy equipment–personal injury or equipment damage might result if mishandled. v Always lower the leveling pads on the rack cabinet. v Always install stabilizer brackets on the rack cabinet. v To avoid hazardous conditions due to uneven mechanical loading, always install the heaviest devices in the bottom of the rack cabinet.
Page 10
CAUTION: Removing components from the upper positions in the rack cabinet improves rack stability during relocation. Follow these general guidelines whenever you relocate a populated rack cabinet within a room or building: v Reduce the weight of the rack cabinet by removing equipment starting at the top of the rack cabinet.
Page 11
(L003) All lasers are certified in the U.S. to conform to the requirements of DHHS 21 CFR Subchapter J for class 1 laser products. Outside the U.S., they are certified to be in compliance with IEC 60825 as a class 1 laser product.
Page 12
CAUTION: Data processing environments can contain equipment transmitting on system links with laser modules that operate at greater than Class 1 power levels. For this reason, never look into the end of an optical fiber cable or open receptacle. (C027) CAUTION: This product contains a Class 1M laser.
RAID 0, 10, 5, and 6 and hot spare. The 58/88 or ED/R1 PCIe storage enclosure is a one EIA unit (1U) drawer that mounts in a 19-inch rack. It is designed for light path service with light-emitting diode (LED) indicators on the front and rear of the enclosure chassis.
With the 58/88 or ED/R1 PCIe storage enclosures, all of the necessary components are integrated within the storage enclosure. Figure 2 on page 3 shows a dual storage IOA solution integrated within the 58/88 or ED/R1 PCIe storage enclosure. Power systems: Service procedures for the PCIe storage enclosure...
SAS cables. v Increased number of 1.5-inch solid-state drives (SSDs) (up to 30). PCIe storage enclosure features This table shows the main features of the 58/88 and ED/R1 PCI Express (PCIe) storage enclosures. Table 1. PCIe storage enclosure features Feature code...
Use this as a guide for cabling your PCIe storage enclosure to a 31E/1C or 31E/2C system. Figure 3 on page 5 shows an example of connecting a 58/88 PCIe storage enclosure to a 31E/1C or 31E/2C system using two FC EJ0H GX adapters.
Page 17
Figure 3. One 58/88 PCIe storage enclosure connected to a 31E/1C or 31E/2C system using two FC EJ0H GX adapters Figure 4 on page 6 shows one 58/88 PCIe storage enclosure connected to two 31E/1C or 31E/2C systems using two FC EJ0H GX adapters.
Figure 4. One 58/88 PCIe storage enclosure connected to two 31E/1C or 31E/2C systems using two FC EJ0H GX adapters Figure 5 shows two 58/88 PCIe storage enclosures connected to two 31E/1C or 31E/2C systems using four FC EJ0H GX adapters.
Page 19
Figure 6. One 58/88 PCIe storage enclosure connected to a single 02E/4C or 05E/6C system by using one FC EJ03 GX adapter Figure 7 on page 8 shows one 58/88 PCIe storage enclosure connected to a 02E/4C or 05E/6C system by using two FC EJ03 GX adapters.
Page 20
Figure 7. One 58/88 PCIe storage enclosure connected to a single 02E/4C or 05E/6C system by using two FC EJ03 GX adapters Figure 8 shows two 58/88 PCIe storage enclosures connected to a single 02E/4C or 05E/6C system by using two FC EJ03 GX adapters.
Page 21
Figure 9. One 58/88 PCIe storage enclosure connected to two 02E/4C or 05E/6C systems by using two FC EJ03 GX adapters. Figure 10 on page 10 shows two 58/88 PCIe storage enclosures connected to two 02E/4C or 05E/6C systems by using two FC EJ03 GX adapters.
Page 22
Figure 10. Two 58/88 PCIe storage enclosures connected to two 02E/4C or 05E/6C systems by using two FC EJ03 GX adapters. Figure 11 on page 11 shows four 58/88 PCIe storage enclosures connected to two 02E/4C or 05E/6C systems by using four FC EJ03 GX adapters.
Figure 11. Four 58/88 PCIe storage enclosures connected to two 02E/4C or 05E/6C systems by using four FC EJ03 GX adapters. Cabling the ED/R1 PCIe storage enclosure to a 17M/MD or 79M/HD system Use this reference information as a guide for cabling your PCIe storage enclosure to a 17M/MD or 79M/HD system.
Page 24
Figure 12. One ED/R1 PCIe storage enclosure connected to a single 17M/MD or 79M/HD system by using one FC 1914 GX adapter Figure 13 on page 13 shows one ED/R1 PCIe storage enclosure connected to a 17M/MD or 79M/HD system by using two FC 1914 GX adapters. Power systems: Service procedures for the PCIe storage enclosure...
Page 25
Figure 13. One ED/R1 PCIe storage enclosure connected to a single 17M/MD or 79M/HD system by using two FC 1914 GX adapters Figure 14 shows two ED/R1 PCIe storage enclosures connected to a single 17M/MD or 79M/HD system by using two FC 1914 GX adapters. Figure 14.
Page 26
Figure 15. One ED/R1 PCIe storage enclosure connected to two 17M/MD or 79M/HD systems by using two FC 1914 GX adapters. Figure 16 on page 15 shows two ED/R1 PCIe storage enclosures connected to two 17M/MD or 79M/HD systems by using two FC 1914 GX adapters. Power systems: Service procedures for the PCIe storage enclosure...
Page 27
Figure 16. Two ED/R1 PCIe storage enclosures connected to two 17M/MD or 79M/HD systems by using two FC 1914 GX adapters. Figure 17 on page 16 shows four ED/R1 PCIe storage enclosures connected to two 17M/MD or 79M/HD systems by using four FC 1914 GX adapters. Service information...
Figure 17. Four ED/R1 PCIe storage enclosures connected to two 17M/MD or 79M/HD systems by using four FC 1914 GX adapters. Cabling the 58/87 disk drive enclosure to an ED/R1 PCIe storage enclosure Use this reference information as a guide for cabling your disk drive enclosure to your PCIe storage enclosure.
Page 29
Figure 18. One 58/87 disk drive enclosure connected to a single ED/R1 PCIe storage enclosure. Figure 19 on page 18 shows four 58/87 disk drive enclosures connected to two ED/R1 PCIe storage enclosures. Service information...
Figure 19. Four 58/87 disk drive enclosures connected to two ED/R1 PCIe storage enclosures Overview of problem determination The error log analysis is performed on errors presented by the components in the 58/88 or ED/R1 PCIe storage enclosure and recommends actions that need to be performed to correct the errors. Sometimes it refers you to an isolation procedure to further determine what actions can be taken to resolve the problem.
LED usage for the 58/88 or ED/R1 PCIe storage enclosure The components inside the 58/88 or ED/R1 PCIe storage enclosure can be identified by their physical location code. In addition to the location code, most components have an identify light-emitting diode (LED) that can be activated.
Page 32
Use one of the following options to determine the RAID controller physical location: v “Use the adapter VPD information” v “Find the port of the GX adapter” v “Use the operating system tools” Use the adapter VPD information You can display the adapter vital product data (VPD) to determine whether the FRU label field contains a location.
Page 33
Information similar to the following is displayed: ------------------------------------------------------------------------ Name Resource State Description Size ------------------------------------------------------------------------ sissas2 FEFFFFFF Secondary PCIe2 3.6GB Cache RAID SAS Enclosure 6Gb sissas1 FEFFFFFF HA Linked Remote adapter SN 0019P00J pdisk0 000000FF RWProtected SSD Array Candidate pdisk1 000006FF RWProtected SSD Array Candidate pdisk2 000007FF RWProtected SSD Array Candidate pdisk4...
Determining the ERM location from the RAID controller location when using Linux: Learn how to use Linux to determine the physical location of the RAID controller on the enclosure RAID module (ERM) when you have the RAID controller logical location code. Use one of the following options to determine the RAID controller physical location: v “Find the port of the GX adapter”...
7. Use the matching SES in screen 1 to find out the physical location of the RAID controller in screen 2. Updating microcode for PCIe storage enclosure components The 58/88 or ED/R1 PCIe storage enclosure have hardware components that require microcode updates. The following hardware components can be updated concurrently:...
Storage enclosure topology Find information to help you locate components within the 58/88 or ED/R1 PCIe storage enclosure. Figure 20 on page 25 shows the location of components within the 58/88 or ED/R1 PCIe storage enclosure. Power systems: Service procedures for the PCIe storage enclosure...
Page 37
Figure 20. Component locations Figure 21 on page 26 shows the SAS physical links (phys) of components within the 58/88 or ED/R1 PCIe storage enclosure. Service information...
Page 38
Figure 21. SAS physical links Power systems: Service procedures for the PCIe storage enclosure...
Notices This information was developed for products and services offered in the U.S.A. The manufacturer may not offer the products, services, or features discussed in this document in other countries. Consult the manufacturer's representative for information on the products and services currently available in your area.
This information is for planning purposes only. The information herein is subject to change before the products described become available. This information contains examples of data and reports used in daily business operations. To illustrate them as completely as possible, the examples include the names of individuals, companies, brands, and products.
Page 41
equipment in a residential area is likely to cause harmful interference, in which case the user will be required to correct the interference at his own expense. Properly shielded and grounded cables and connectors must be used in order to meet FCC emission limits.
Page 42
Japanese Electronics and Information Technology Industries Association (JEITA) Confirmed Harmonics Guideline (products less than or equal to 20 A per phase) Japanese Electronics and Information Technology Industries Association (JEITA) Confirmed Harmonics Guideline with Modifications (products greater than 20 A per phase) Electromagnetic Interference (EMI) Statement - People's Republic of China Declaration: This is a Class A product.
Page 43
Electromagnetic Interference (EMI) Statement - Korea Germany Compliance Statement Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse A EU-Richtlinie zur Elektromagnetischen Verträglichkeit Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse A ein.
Generelle Informationen: Das Gerät erfüllt die Schutzanforderungen nach EN 55024 und EN 55022 Klasse A. Electromagnetic Interference (EMI) Statement - Russia Class B Notices The following Class B statements apply to features designated as electromagnetic compatibility (EMC) Class B in the feature installation information. Federal Communications Commission (FCC) statement This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to Part 15 of the FCC Rules.
Page 45
European Community Compliance Statement This product is in conformity with the protection requirements of EU Council Directive 2004/108/EC on the approximation of the laws of the Member States relating to electromagnetic compatibility. IBM cannot accept responsibility for any failure to satisfy the protection requirements resulting from a non-recommended modification of the product, including the fitting of non-IBM option cards.
Germany Compliance Statement Deutschsprachiger EU Hinweis: Hinweis für Geräte der Klasse B EU-Richtlinie zur Elektromagnetischen Verträglichkeit Dieses Produkt entspricht den Schutzanforderungen der EU-Richtlinie 2004/108/EG zur Angleichung der Rechtsvorschriften über die elektromagnetische Verträglichkeit in den EU-Mitgliedsstaaten und hält die Grenzwerte der EN 55022 Klasse B ein. Um dieses sicherzustellen, sind die Geräte wie in den Handbüchern beschrieben zu installieren und zu betreiben.
Page 47
these publications, or reproduce, distribute or display these publications or any portion thereof outside your enterprise, without the express consent of the manufacturer. Rights: Except as expressly granted in this permission, no other permissions, licenses or rights are granted, either express or implied, to the Publications or any information, data, software or other intellectual property contained therein.
Page 48
Power systems: Service procedures for the PCIe storage enclosure...
Need help?
Do you have a question about the 58/88 and is the answer not in the manual?
Questions and answers