Mobile parts cleaning tank 50ltr

Advertisement

Avoid unintentional starting.
9
DO NOT overfill tank or allow fluid level to fall below pump inlet.
8
DO NOT use the tank for a task it is not designed to perform.
8
DO NOT operate the tank if any parts are damaged or missing as this may cause failure and/or personal injury.
8
DO NOT allow untrained persons to operate the tank.
8
DO NOT operate the tank when you are tired or under the influence of alcohol, drugs or intoxicating medication.
8
DO NOT leave the tank operating unattended.
8
When not in use switch off the tank, close the lid and remove the plug from the power supply.
9
Dispose of waste liquids in accordance with local authority regulations.
9
WARNING! Protect the environment - DO NOT allow uncontrolled discharge of pollutants.
Keep the tank clean for the best and safest performance.
9
2. INTRODuCTION
Heavy duty one-piece tank. Fully sealed electric motor with magnetic drive pump unit. Lid features self-latching fusible link which automatically
snaps lid shut in the event of fire. Includes removable shelf and small parts basket. Flexible metal nozzle directs solvent over work. Stand fitted
with four Ø100mm castors for easy manoeuvrability, two of which are lockable.
3. SPECIFICATION
Model no .......................................................................SM28
Max. working capacity ..................................................... 50ltr
Min. working capacity ...................................................... 40ltr
Motor power ....................................................................25W
Weight ....................................................................... 26.82kg
Dimensions (W x D x H) ..........................810 x 540 x 898mm
Tank dimensions .....................................810 x 540 x 260mm
Pump output/hr ............................................................. 200ltr
Supply ............................................................................230V
Degreasing solvent emulsifiable 20ltr ............................ AK20
25ltr ............................................................................... AK25
Degreasing solvent 25ltr ........................................... AK2501
20ltr ........................................................................... AK2001
4. ASSEmBLY
Refer to Parts List
4.1.
Remove parts from packing and take items out of the tank. Before assembly check parts to ensure they are complete and not damaged.
4.2.
Close lid (4) of tank (1), gently turn unit upside down. Rest tank on a clean soft surface (i.e. cardboard) ensuring lid is secured in the
closed position.
4.3.
Attach the four legs (21) to the tank brackets with the pan head screws, spring washers and hex nuts (22, 23, 24) but do not tighten.
4.4.
Place the lower shelf (20) between the four legs (21) with flat surface facing downward and fix with screws, washers and hex nuts (22,
23, 24).
4.5.
With the legs pressed tightly against the lower shelf, tighten all the screws commencing with those attaching the shelf.
4.6.
Fit one castor wheel assembly (47) to each rear leg, and one lockable wheel (46) to each of the front legs, and secure in place with a
nut (48) and washer (49) on each.
4.7.
Hold the lid closed and stand the assembled unit upright. Open the lid but do not extend the lid too far.
4.8.
Place the tank work shelf (42) on the two welded supports located inside the tank.
4.9.
Remove the self tapping screws (35) from the cover of the pump unit and check to see if there is any supporting packing inside. If so,
remove the supporting packing and replace the cover and tighten the screws.
4.10.
Place the pump into the tank unit and pass the switch unit through the slot in the cleaning tank side. As the unit protrudes through the
slot, secure it by placing the underside lip over the edge of the tank. Attach the flexible pipe (27) to the pump.
5. OPERATION
WARNING! Wear safety clothing, eye protection and gloves and ensure you read, understand and apply the safety instructions in
Section 1.
5.1.
Ensure the unit is located on a firm level surface in a well ventilated area and is switched off and unplugged from the mains power supply.
5.2.
Ensure the castors are locked once in position.
5.3.
Fill the tank with solvent (see below), tank capacity is 50 litres. Minimum level must cover pump inlet, approximately 40 litres. Follow the
solvent's safety instructions on its packaging.
5.4.
Plug the unit into the mains power supply and switch the unit on. The cleaning agent will flow through the flexible tube.
5.5.
Place parts to be washed into the basket, or directly into the tank. Direct solvent flow onto parts. Heavily soiled items may be left to soak
before cleaning.
DO NOT leave the unit operating unattended. Check the fluid level does not fall below the pump inlet.
8
5.6.
When cleaning is complete, remove all parts, whilst ensuring the minimum of cleaning agent spillage.
5.7.
Switch off the unit, close the lid and disconnect the unit from the mains power supply. Clean up any spillage.
5.8.
Dispose of waste liquids in accordance with local authority regulations.
ImPORTANT! The SM28 has an anti-fire device built into the unit. In the event of a fire, the lid will automatically close.
DO NOT prop the lid open as this will prevent the automatic safety feature from operating.
8
When cleaning parts, ensure that nothing in the tank, including any parts basket, is in a position that would prevent the lid from closing
fully, if and when the fusible link activates.
Once actuated, the fire detection device cannot be re-used and must be replaced before further use.