List ◆Thank you for purchasing the Smart-g Boiler Safety instructions • ㆍ Caution before use ㆍ Caution in use ㆍ Identification of components How to use • ㆍ Remote controller ㆍ Operation procedure ㆍ Heating ㆍ going out(Heating) ㆍ Heating Interval(Heating) ㆍ...
Page 3
Safety instructions ■This is to prevent potential dangers or accidents by using product safety and properly. Please keep this in mind Danger If you ignore this mark and misuse, it could cause death or serious injury. Warning If you disregard this mark, a user might get a serious injury. Caution If you neglect this mark, a user can get harm or physical damage.
Page 4
Caution before use Warning ■Check your supply gas. ■Do not keep inflammables close. ㆍDo not keep any inflammables such as ㆍThe type of gas is stated on the side of spray, gasoline and benzene around product. If you use different kind of gas, it product.
Page 5
Caution in use Warning ■If malfunctioning or gas leakage is ■Do not separate connector of exhaust detected..pipe. ㆍStop operating, and contact installer or ㆍIf exhaust gas indraft into indoor, it will call for our service center. happen to gas poisoning. Must do Must do ■Do not dismantle, repair or modify except...
Page 6
Identification of components Exhaust Pipe Pressure Gauge Gas Inlet Water Filling Valve Heating Outlet Heating Return Hot Water Outlet Cold Water Inlet...
Page 7
Block Diagram ⑮ ① ② ③ ⑭ ⑬ ④ ⑫ ⑤ ⑪ ⑥ ⑦ ⑩ ⑧ ⑨ ① Expansion Tank ⑨ Flow detector ② Hot water flow Switch ⑩ Circulation Pump ③ Ignition Plug ⑪ Safety valve (Hose) ④ Aps Switch ⑫...
Page 8
How to use Remote controller Freeze Protection On/Off Heating Temperature Bath On Heating On/Off Hot water Temperature Current Temperature Going Out Checkup Heating Interval Check Lamp Combustion Lamp Bath Only Heating+Bath Button Temperature Up Heating Interval Temperature Button Setting Going Out Setting Power Button Temperature Down Components...
Page 9
Operation Procedures Heating ▶ How to Set Heating Temperature Press Heating+Hot Water button for 3 seconds. When ‘Heating Temperature’ display flickers, heating Heating+ Hot Water temperature by pressing the button flickers when the Up or Down button. (Press boiler starts working. Heating+Hot Water button Combustion lamp is on again or wait for 5 seconds,...
Page 10
Going out (Heating) Press Going Out button. When Going Out button is on, Turn Heating Operation for Going Out starts. on by pressing Heating button. For <Room Heating> For <Floor Heating> ▶What is Operation for Going Out? Warm the rooms by operating the boiler at the minimum level when no one is at home. To cancel Operation for Going Out, press the Going Out button again or Heating button.
Page 11
Bath Even when the Bath button on the remote controller is on, the boiler doesn’t work to supply hot water if hot water is not used. Press the Bath button for 3 seconds. When ‘Temperature’ Turn the Bath display flickers, set the hot water temperature by pressing the Up or function on by Down buttons.
Page 12
Cleaning and maintenance Warning ■Check if there is deformation on ■Do not clean using water soaked product or deformation over ventilating cloth shaft. And check if ventilating shaft is come off •Electroshock or from product.. breakdown could •If exhaust gas leaks, happen.
Page 13
Measures when safety device is on When the boiler doesn’t work and the Failure code on the LCD panel of the remote controller flickers, check the following and take the proper action. Failures Failure Codes Symptoms and Causes Hot Water Temperature Sensor Disconnection or short circuit of hot water temperature Failure sensor...
Page 15
Before ask for service Trouble Checking point Trouble shooting condition (1) Do not light match and lighter & Do not turn on the light. (2) Stop using boiler immediately Close gas intermediate valve, and contact with a special gas supply installer. (3) Check regularly if there is a gas leakage by pasting spraying a soapy water.
Page 16
Instruction of installation Caution for installation To person who installs. Caution ㆍInstallation must be done by authorized professionals. If not, you will be punished by the relative law. ㆍRead this manual carefully before installing. (When installation is not consistent with this manual, we are not responsible any damages) ㆍIf air supply or exhaust gas pipe is not correctly connected, user can suffer from gas poisoning due to gas leakage.
Page 17
Instruction of installation Caution for installation Location Warning ■Please, Install the boiler in the exclusive place. (Forced Exhaust type FE) ㆍThe exclusive place where is keep with air supply and exhaust should be install. Forced draught balanced flue type (FF type) should be install exclusive place only except following case①...
Page 19
Pipework Pipe Connection ① Heating water Outlet ② Heating water Return ③ Hot water Outlet ④ Gas Inlet ⑤ Cold water Inlet Install butterfly valve for each valve Open the every distribution point such as Water Pipe, Gas Pipe etc to protect freezing in cold weather during away from home for long period Do not cut off Gas and Electricity...
Page 20
Pipe Construction Electric wiring For this product, AC220V power source is necessary Electric wiring Caution for electric wiring work, inquire a professional electrical company must be grounded ㆍ Grounding ㆍIt should be install grounding work to prevent from an electric shock and short circuit by leakage an electric current boiler ㆍConnecting grounding wire with metal piece and bury it in humid underground.
Page 21
Antifreezing of pipe Caution ㆍKeep a warm a Insulating material with thickness 25mm over. (Cold area 50mm over). ㆍEspecially, the surface of hot water heating pipe have to installed heat wire to prevent from severe cold winter. (Heat wire must be purchase, only) ㆍDo not wrap the drain knob and filter with insulating material.
Page 22
Room Heating Piping construction Connect with pipe diameter of 20A (PT3/4”) . It should be buried pipe but it must not be connected at buried place It is difficult maintenance when there is a leakage . It should be used same size of diameter for inlet pipe and return pipe. .
Page 23
Air Supply/Exhaust Tube Installation ■Diameter of air supply/exhaust tube Outer Diameter Through Wall Tube Size (mm) of Tube Size (mm) 60(75) Over 100 Warning! Use only the tube that satisfies the specifications. If the diameter of tube doesn’t fit, exhaust gas can leak and cause carbon monoxide Caution poisoning.
Page 24
Air supply / exhaust pipe installation (Unit : mm) ㆍRestricted to the distance from top of exhaust to the window Warning Must be followed ■Exhaust pipe installed tilt about 3 down direction to outside for the prevent of back flow. ■At the end of the exhaust pipe, install an insect net to prevent a ball from entering.(a ball of diameter 16mm) ■There is no obstacle from end of Exhaust pipe to...
Page 25
How to Install Remote Controller Site Requirements Mount the remote controller on the wall without any obstacles at a height of 1.2 to 1.5m from the floor for simple control on the room temperature or hot water in a room or a living room. ...
Page 26
How to Install Remote Controller Install the remote controller wire where it will not be directly influenced by heat. Mounting Remote Controller Wall Mounting Drill the hole for the plug on the wall (6.0 x 35~40mm deep). Insert the plug. The hole must be drilled at a right angle.
Page 27
Test running When filling water, the LCD panel on the remote controller displays Heating and Bath. Do not control the buttons on the remote controller at that moment. When filling water during the test run, turn the Heating and Bath buttons off (initial setting of the product), unplug the power.
Page 28
Item Procedure Remarks ① Connect the drain hole on the Drain Pipe Installation (Check) If the drain hose is not connected bottom left of the boiler to the to the drain pipe, water from the drain pipe using the flexible hose. ②...
Page 30
SPARE PARTS LIST Parts List No. Description Unit Q'tity Model Photograph SSB-10K, 13K, SSB1025ML0001A Expanion Tank 16K, 20K, 25K SSB-30K, 35K, SSB3040ML0001A Expanion Tank Heating SSB-10K-40K Temperature Sensor SSB1040ML0001A DHW Temperature SSB-10K-40K Sensor SSB1040ML0002A Main Controller SSB-10K-40K SSB1040ML0003A Circulation Pump SSB-10K-40K SSB-10K, 13K, SSB1040ML0004A...
Page 33
Indemnity Damages Compensation Standards Remarks Performance or functional Replacement or refund Calculation expenses defects occurred under the replacement refund: normal operation status and Installation expenses required requiring maintenance service for re-installation included. within 10 days after purchase Performance or functional Repair without defects occurred under the...
Page 34
Warranty Model Date of Purchase Vendor Manufacturing No. Name Warranty Period Vendor Address Date of Repair Description Engineer Confirm This Product successfully passed the strict quality management and close inspection. We guarantee repair, replacement or refund for any reasonable customers’ damages in accordance with the Consumer Damage Compensation Regulations published by the Ministry of Finance and Economy.
Page 35
Address : 75, Seokmun-gil, Seonggeo-eup, Seobuk-gu, Cheonan-si, Chungcheongnam-do, Korea Tel : +82-41-583-7200, 7211, 7213 FAX : +82-41-583-7500 Home Page : http://www.smart-g.net...
Need help?
Do you have a question about the SSB10 and is the answer not in the manual?
Questions and answers