Filo FILO400C Instructions And Warnings For Installation And Use

Filo FILO400C Instructions And Warnings For Installation And Use

Mhouseplus
Table of Contents

Advertisement

Quick Links

Filo
FOR SLIDING GATES
Pour portails coulissants
FR - Instructions et avertissements pour l'installation et l'utilisation
EN - Instructions and warnings for installation and use
IT - Istruzioni ed avvertenze per l'installazione e l'uso
PL - Instrukcje i ostrzeżenia do instalacji i użytkowania

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the FILO400C and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Filo FILO400C

  • Page 1 Filo FOR SLIDING GATES Pour portails coulissants FR - Instructions et avertissements pour l’installation et l’utilisation EN - Instructions and warnings for installation and use IT - Istruzioni ed avvertenze per l’installazione e l’uso PL - Instrukcje i ostrzeżenia do instalacji i użytkowania...
  • Page 2 Step FL200 PH200 PH200 FILO400C FILO600C CR502 A B C D See Table 1 (Par. 3.4) Step Installation with rack to be mounted: see Fig. Installation with existing rack: see Fig. 5 (Par. 4 (Par. 3.5.1) for the relevant procedure...
  • Page 3 0 ÷ 50 0 ÷ 50 > 40 cm 35÷40 mm 0 ÷ 50 20/30 mm 40 mm 40 mm 180° ➠...
  • Page 4 ➠ 1÷2 mm 2-3 cm 180° 2-3 cm PH200 Installation of photocells > Fig. 6 - Paragraph 3.6 FL200 Installation of photocells > Fig. 7 - Paragraph 3.7...
  • Page 5 0 ÷ 50 0 ÷ 50 > 40 cm 35÷40 mm 0 ÷ 50 20-30 mm 180° ➠...
  • Page 6 ➠ 1÷2 mm 2-3 cm 15 . 180° 2-3 cm PH200 Installation of photocells > Fig. 6 - Paragraph 3.6 FL200 Installation of photocells > Fig. 7 - Paragraph 3.7...
  • Page 7 PH200 Led SAFE Ø < 5 mm Flash Fuse 1.6A T ECSbus Stop Aerial VIII...
  • Page 8 FL200 05. A Ø = 6 mm 05. B Ø = 6 mm (flash) (aerial) Step...
  • Page 9 Step 24 V 4 W led ECS led Stop led SbS Fuse 15A...
  • Page 10 After having connected components of the kit and before closing the cover of the gear motor (Fig. 9), it is possible to connect other com-ponents designed for the system (optional and not present in the package). Step To start-up the system, see Chapter 5. Step To PROGRAMME the system, see Chapter 6.
  • Page 11: Table Of Contents

    3.1 VERIFYING THE SUITABILITY OF THE GATE AND ENVIRONMENT 3.2 VERIFYING THE PRODUCT’S APPLICATION LIMITS 3.3 PRODUCT TECHNICAL SPECIFICATIONS 3.4 PRE-INSTALLATION WORKS 3.5 INSTALLING THE FILO GEARMOTOR (model 400C/600C) 3.5.1 INSTALLATION WITH RACK TO BE MOUNTED 3.5.2 INSTALLATION WITH EXISTING RACK 3.6 INSTALLING THE PHOTOCELLS model PH200...
  • Page 12: General Warnings: Safety - Installation - Use

    GENERAL WARNINGS: SAFETY - INSTALLATION - USE (original instructions in Italian) CAUTION Important safety instructions. Observe all the instructions as improper installation may cause serious damage CAUTION Important safety instructions. It is important to comply with these instructions to ensure personal safety. Store these instructions •...
  • Page 13: Product Description And Intended Use

    Before proceeding with the installation, carry out the following checks and verify the "Product technical characteristics" (Paragraph 3.3): 01. Check that the dimensions and weight of the gate leaf fall within the following limits: FILO400C: maximum length 5,5 m; maximum weight 400 kg FILO600C: maximum length 7 m; maximum weight 600 kg 02.
  • Page 14: Pre-Installation Works

    SbS input For normally open contacts (closing of the contact triggers the Step-by-Step (SbS) command) Stop input For normally open contacts and/or for 8.2 kΩ constant resistance, or normally closed contacts with self-recognition of the “normal” status (any variation from the memorised status triggers the Stop command) Radio aerial input 50Ω...
  • Page 15: Installing The Filo Gearmotor Model 400C/600C

    3.5 - INSTALLING THE FILO GEARMOTOR model 400C/600C • All installation operations must be made with the system disconnected from the power supply. If the back-up battery is present, it must be disconnected • Incorrect installation may cause serious physical injury to those working on or using the system.
  • Page 16: Installation With Existing Rack

    At this point it is possible to install the accessories that belong to the system: for photocells PH200 > Par. 3.6 (Fig. 6) - for flashing light FL200 > Par. 3.7 (Fig. 7). For other optional accessories, consult the respective instruction manuals. PH200 3.6 - INSTALLING THE PHOTOCELLS model PH200 (Fig.
  • Page 17: Programming

    ECSbus ECSbus Step PROGRAMMING Stop Stop 5.1 - CONTROL UNIT KEYS The control unit has four programming keys with their respective LEDs: Aerial Aerial keys P1, P2, P3, P4 and LEDs L1, L2, L3, L4 (Fig. 12) P1 = Step-by-Step command P2 = slow/fast movement speed selection (Par.
  • Page 18: Memorisation Of The Gate Leaf Length (Opening And Closing)

    Flash Flash Fuse 1.6A T Fuse 1.6A T Flash Flash Fuse 1.6A T Fuse 1.6A T ECSbus ECSbus ECSbus Sbus ECSbus Stop Aerial A A erial Stop Aerial 5.4 - MEMORISATION OF THE GATE LEAF LENGTH (opening and closing) After recognition of the devices (Par. 5.3) it is necessary to make the control unit memorise the length of the gate leaf, which is measured from the clos- ing limit switch to the opening limit switch.
  • Page 19: Basic Adjustments

    Fuse 1.6A T Fuse 1.6A T ECSbus ECSbus Stop Stop TABLE 1 Keys Paired command Aerial Step-by-Step (SbS) Partial open Open only Close only 230 V light output: On - Off Memorisation procedure 01. On the control unit (Fig. 22) press and hold button P4 for 3 seconds; when led L4 switches on, release the button. 02.
  • Page 20: Commissioning

    6.2 - COMMISSIONING Commissioning can only be performed after all test phases have been successfully completed. Partial or “makeshift” commissioning is strictly prohibited. 01. Draw up the technical file of the automation which should at least include: assembly drawing (for example as in Fig. 3), wiring diagram (for example Fig.
  • Page 21: Advanced Adjustments

    It is possible to add or remove devices at any time to the system: if devices are added, it is important to verify that these are perfectly compatible with FILO 400C/FILO 600C; for further details contact the Nice technical support service.
  • Page 22: Memorising Additional Transmitters

    02. Wait a few seconds until the control unit has completed the device recognition procedure: led L2 switches off. If instead it flashes, it means that there is some error – see Chapter 10. 03. After adding or removing devices, the automation must be tested again (Par. 6.1). 9.3 - MEMORISING ADDITIONAL TRANSMITTERS The control unit incorporates a radio receiver for ECCO5 transmitters (various models).
  • Page 23: Deleting The Memory Of The Individual Transmitter From The Control Unit's Memory

    release it. 03. On the OLD transmitter press and hold the key to be copied for at least 2 seconds then release it. 04. On the OLD transmitter press and hold the key to be copied for at least 2 seconds then release it. 05.
  • Page 24: 230 V Light Output Connection

    9.8 - CONNECTING THE 230 V LIGHT OUTPUT To perform the connection see Fig. 31 and consult the relevant instruction manual. 230 V, 500 W max 9.9 - INSTALLING THE EXTERNAL RELEASE SYSTEM model KS200KIT To install the KS200KIT external release system in the gearmotor, see Fig. 32 and consult the relevant instruction manual. 9.10 - DIAGNOSTICS AND DEVICE SIGNALS Certain devices are configured to display messages to identify their operating status or any anomalies.
  • Page 25: Flashing Light Signals

    9.10.2 - Flashing light signals During the manoeuvre, the flashing light emits 1 flash each second; when there is an anomaly, it flashes quickly: see Table 7. TABLE 7 Flashes (quick) Status Action 1 flash ECSBus error At the beginning of the manoeuvre the devices present do not match those recog- 1 second pause nised;...
  • Page 26: Specifications

    02. In Graph 1, from the value obtained above, trace a vertical line until it intersects the curve; from this point trace a horizontal line until it intersects the line of the “manoeuvre cycles”. The value obtained is the estimated lifetime of your product. FILO400C FILO600C...
  • Page 27: Troubleshooting

    Example of durability calculation: automation of a 3.5 m gate leaf weighing 250 kg, installed in the vicinity of the sea. Table 10 shows the “severity indices” for this type of installation: 10% (Leaf length), 20% (Leaf weight) and 15% (Presence of dust, sand or salinity). These indices must be added to each other to obtain the overall severity index, which in this case amounts to 45%.
  • Page 28 The FILO gearmotor (model 400C/600C) is equipped with a mechanical system that allows for opening and closing the gate manually. Manual operation must be performed in the case of a power outage or in the event of anomalies affecting the system. In case of a power outage, a back-up battery can be used (model PR100 - not supplied) (see Chapter 9 - Further information, or the relevant instruction manual).
  • Page 29 Service Après Vente France En cas de panne, merci de contacter obligatoirement notre Service Après Vente par téléphone ou par email : 0 820 859 203 Service 0,15 €/min + prix appel niceservice@niceforyou.com Merci de ne pas retourner le produit en magasin Worldwide Customer Service customerservice@niceforyou.com Nice S.p.A. Via Pezza Alta, 13 31046 Oderzo TV Italy www.niceforyou.com info@niceforyou.com...

This manual is also suitable for:

Filo600c

Table of Contents