Table of Contents

Advertisement

Available languages

Available languages

Driver for Klockner Moeller PS series
English
Svenska
© Beijer Electronics AB 2000, MA00500, 2000-09
Beijer Electronics AB reserves the right to change information in this manual without
prior notice. All examples in this manual are used solely to promote understanding of
how the program works and its operation. Beijer Electronics AB take no responsibility if
these examples are used in real applications.

Advertisement

Chapters

Table of Contents
loading
Need help?

Need help?

Do you have a question about the PS Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Klockner Moeller PS Series

  • Page 1 Driver for Klockner Moeller PS series English Svenska © Beijer Electronics AB 2000, MA00500, 2000-09 Beijer Electronics AB reserves the right to change information in this manual without prior notice. All examples in this manual are used solely to promote understanding of how the program works and its operation.
  • Page 2 Klockner Moeller PS series This manual presents installation and handling of the driver Klockner Moeller PS series SUCOM-A to the terminals in the E-series. The functionality in the E-terminals and in MAC Programmer+ are described in the E-manual. © Beijer Electronics AB 2000, MA00500, 2000-09 Beijer Electronics AB reserves the right to change information in this manual without prior notice.
  • Page 3: Table Of Contents

    Content Content 1 Introduction ...................3 2 Install and update driver ...............4 2.1 Installation of driver using Internet ..........4 2.2 Installation of driver from disk ............4 3 Connecting the terminal to the PLC system .........5 3.1 Settings in the MAC Programmer+ ..........5 3.2 Settings in the PLC system ...............7...
  • Page 4: Introduction

    E-series, the terminal is master, via the protocol SUCOM- A and how they communicate. Addressing of an item is done in the nor- mal Klockner Moeller way. For information about the PLC system we re- fer to the manual for current system.
  • Page 5: Install And Update Driver

    Then you select Install. How to select the Klockner Moeller SUCOM-A driver in the project and how to transfer it to the terminal are described in chapter 3.
  • Page 6: Connecting The Terminal To The Plc System

    Connecting the terminal to the PLC system Connecting the terminal to the PLC system 3.1 Settings in the MAC Programmer+ For communication with the PLC system via the protocol SUCOM-A the following settings must be made in the programming tool MAC Programmer+.
  • Page 7 Connecting the terminal to the PLC system Communication setup The settings for the communication between the terminal and the PLC system are done under Peripherals in the Setup menu. To change which port the PLC system is connected to, mark Controller and hold left mouse button down and drag to move it to another communication port.
  • Page 8: Settings In The Plc System

    Connecting the terminal to the PLC system Transfer the driver to the terminal The selected driver is downloaded into the terminal when the project is transferred to the terminal. Choose Project in the Transfer menu. There are three alternatives when the driver is downloaded into the termi- nal: Function Description...
  • Page 9: Connecting The Terminal To The Plc System

    RS-232 or RS-422 The point-to-point connection can be done either via the RS-422 port or via the RS-232C port on the terminal. The Klockner Moeller PS4 series control- lers are connected to the RS-232C port on the terminal with cable accord- ing to the cable drawing below or with the programming cable for the PLC system together with the cable adapter CAB12.
  • Page 10: Addressing

    Addressing Addressing The terminal can handle different data types in the PLC system. Following devices can be addressed: Digital objects: Type Address Comment MX.rr.bb MX0.0-MX65534.7 Bit bb in byte rr Comments about digital objects If You choose to manouver a digital object, the terminal handle this by read before write.
  • Page 11: Efficient Communication

    Efficient communication Efficient communication To make the communication between the terminal and the PLC system quick and efficient the following should be noted about how the signals are read and what that can be done to optimize the reading. 5.1 Signals affecting the communication time It is only signals to objects in the current block that are read continuously.
  • Page 12: How To Make The Communication More Efficient

    The waste depends on the used driver. In the Klockner Moeller PS series driver the number is 8 for analog words, 4 for analog double words and 126 for digital devices.
  • Page 13: Drawings

    Drawings Drawings...
  • Page 14 Drawings...
  • Page 15 Drawings...
  • Page 16 Drawings...
  • Page 17 Klockner Moeller PS series Denna manual är en installations- och hanteringsmanual till drivrutinen Klockner Moeller PS series SUCOM-A till operatörsterminalerna i E- serien. Funktionaliteten i terminalerna och i MAC Programmer+ är be- skriven i E-seriemanualen. © Beijer Electronics 2000 MA00500, 2000-09 Beijer Electronics AB reserverar sig mot att informationen i denna manual kan komma att ändra sig utan föregående varning.
  • Page 18 Innehåll Innehåll 1 Introduktion ...................3 2 Installation och uppdatering av drivrutin ..........4 2.1 Installation av drivrutin med Internet ..........4 2.2 Installation av drivrutin från disk ............4 3 Anslutning av terminalen till PLC- systemet ........5 3.1 Inställningar i MAC Programmer+ ..........5 3.2 Inställningar i PLC-systemet ............7 3.3 Koppla in terminalen till PLC-systemet...
  • Page 19: Introduktion

    Manualen beskriver hur PLC-systemet ansluts till operatörsterminalerna i E-serien och hur de kommunicerar via protokollet SUCOM-A. Adresse- ring i PLC-systemet görs på normalt Klockner Moeller sätt. För informa- tion om PLC-systemet hänvisas till manualen för aktuellt system. Drivrutinen kan användas till PS4-201/271/141/151-MM1 och till...
  • Page 20: Installation Och Uppdatering Av Drivrutin

    Mark Newer markerar alla drivrutiner som finns tillgängliga i en senare version och de som inte är installerade. Välj därefter Install. Hur man väljer Klockner Moeller SUCOM-A drivrutinen i projektet och hur man överför den till terminalen beskrivs i kapitel 3.
  • Page 21: Anslutning Av Terminalen Till Plc- Systemet

    Anslutning av terminalen till PLC- systemet Anslutning av terminalen till PLC- systemet 3.1 Inställningar i MAC Programmer+ För kommunikation med PLC-systemet via protokollet SUCOM-A måste följande inställningar göras i programmeringsverktyget MAC Program- mer+ Val av drivrutin Välj New i File menyn, då skapas ett nytt projekt och dialogen Project Set- tings visas.
  • Page 22 Anslutning av terminalen till PLC- systemet Kommunikationsinställning Inställningarna för kommunikationen mellan terminalen och PLC-syste- met utföres under Peripherals i Setup menyn. För att ändra PLC-syste- mets anslutna port, markera Controller och håll vänster musknapp nere och drag den till en annan kommunikationsport. Markera den valda kom- munikationsporten och tryck Edit för ändra den nya kommunikations- inställningen.
  • Page 23: Inställningar I Plc-Systemet

    Anslutning av terminalen till PLC- systemet Överföra drivrutinen till terminalen Drivrutinen laddas ner till terminalen när hela projektet överförs till ter- minalen. Välj Project i Transfer menyn. Det finns tre olika alternativ när drivrutinen laddas ned till terminalen. Funktion Beskrivning Never Drivrutinen laddas aldrig, befintlig drivrutin i terminalen används.
  • Page 24: Koppla In Terminalen Till Plc-Systemet

    RS-232 or RS-422 Point-to-point anslutningen kan göras antingen via RS-422 porten eller via RS-232C porten på terminalen. Systemen i Klockner Moeller PS4 se- rien ansluts till RS-232C porten på terminalen med kabeln enligt nedan- stående ritningar eller med programmeringskabeln för PLC-systemet tillsammans med kabeladaptern CAB12.
  • Page 25: Adressering

    Adressering Adressering Terminalen kan hantera olika datatyper i PLC-systemet. Följande signaler kan adresseras. Digitala objekt: Adress Kommentar MX.rr.bb MX0.0-MX65534.7 Bit bb i byte rr Kommentarer till digitala objekt Om du väljer att manövrera ett digitalt objekt hanterar terminalen detta genom att läsa före skriva. Det betyder att hela registret läses, önskad bit ändras och därefter skrivs hela registret tillbaka.
  • Page 26: Effektiv Kommunikation

    Effektiv kommunikation Effektiv kommunikation För att göra kommunikationen mellan terminalen och PLC-systemet snabb och effektiv bör följande noteras om hur signalerna läses och vad som kan göras för att optimera detta. 5.1 Signaler som påverkar kommunika- tionstiden Det är endast signalerna till objekten i aktuellt block som läses kontinuer- ligt.
  • Page 27: Hur Kommunikationen Kan Göras Effektivare

    För att minska antalet paket som skall överföras och för att göra kommunikationen snabbare måste man ta hänsyn till detta. Antalet signaler i varje paket beror på drivrutinen. I Klockner Moeller PS serie drivrutinen är antalet 32 st för analoga ord, 16 för analoga dubbelord och 512 för digitala signaler.
  • Page 28: Ritningar

    Ritningar Ritningar...
  • Page 29 Ritningar...
  • Page 30 Ritningar...
  • Page 31 Ritningar...

Table of Contents

Save PDF