Chapter 1 System Structure VTO and VTH are connected as a tree. VTO has a 12V DC adaptor supplying it with power while switch has a 24V DC adaptor supplying it with power.VTO and VTH are connected via switch. The switch supplies VTH with power via network cable. Electric lock, magnetic feedback, door sensor and unlock button all can be connected to VTO, but the VTO does not supply them with power.
UTP Cat5e/Cat6:18.8 ohm/100m Not ok We do not recommend L over 100m. 4. Power line According to distance L between adaptor and VTO, select power line. Power line 0< LC ≤30m 30< LC ≤100m 20AWG Not ok 18AWG 17AWG Note: Before plug in, please make sure + and – end are correctly matched to power end.
Page 4
Chapter 3 FAQ Q:I cannot boot up device. A: 1. Check if the device is plugged into power. Digital VTO requires power voltage of 10V~15V. 2. If VTH is supplied with power by 2-pin port, check VTH’s power supply. It requires voltage of 10V~15V.
Chapter 4 Installation Test Note: The adaptor is not connected to city power grid in step 1-2. 4.1 Install VTO 4.1.1 Connect wire in embedded box to VTO Step 1 Definition of ports: The switch is connected to VTO’s network port.
Page 6
When connect VTO to electric lock, make electric lock + toward VTO NO-end (02.3-pin 1) and electric – toward VTO COM-end (02.3-pin 3). When connect VTO to unlock button, make unlock button’s one end toward VTO (03. 3-pin 2) ALM 2-end and unlock button’s other end toward VTO (03.3-pin 3) GND-end.
Page 7
1)of villa VTO. Villa VTO connects to unlock button, and unlock button’s one end connects to ALM1-end (10-pin port 5) of villa VTO, unlock button’s other end connects to GND-end (10-pin port 4) of villa VTO. Step 3. Install door sensor lock. See Figure 4- 7.
Page 8
Figure 4- 7 When villa VTO connects to door sensor lock, positive end of door sensor lock connects to NC-end(10-pin port 3) of villa VTO and negative end of door sensor lock connects to COM-end (10-pin port 1) of villa VTO.
Page 9
1. Use screw b to fix bracket onto 86 box embedded/120 box embedded inside ③ . 2. Use screw c to fix bracket on ③ . 3. Install VTO ① on VTH bracket ② , and fix with screw a. See Figure 4- 9.Error! Reference source not found.
Page 10
4.2.1 Connect wire in VTH embedded box to VTH port. Connect network port to cable which connects to the switch. Note: If the switch supplies power to VTH, then do not supply DC 12V power to the VTH. Definition of VTH:. 01.
Page 11
Figure 4- 12 01. Reserved port. 02. Test port: connect to external test port. 03. Alarm port: 8-ch alarms. 04. Power: to external DC 12V. 05. Network port: to VTH. See Figure 4- 12. 03. Alarm port definition is as follows: Figure 4- 13 1-ALM1: alarm input port 1 2-ALM2: alarm input port 2...
Page 12
7-ALM6: alarm input port 6 8-ALM7: alarm input port 7 9-ALM8: alarm input port 8 10- GND2: public GND 2 See Figure 4- 13. 4.2.2 Fix VTH on wall. Figure 4- 14 See Figure 4- 14. 1. Fix installation bracket on wall, with screw (M4x30 cross pan head screw). 2.
Page 13
Figure 4- 15 Use screw a to fix bracket ② onto 120 box ③. 2. Use screw b to fix bracket ② onto wall ④ . Face rear installation slot to slot on bracket. Make it against wall and push lightly downward until it is plugged into slot on bracket.
Page 14
Figure 4- 16 Use screw a to fix metal bracket ② onto 86 box ④ . Use screw b to fix metal bracket ② onto wall ③ . Face rear installation slot to slot on bracket. Make it against wall and push lightly downward until it is plugged into slot on bracket.
Page 15
4.3 Test When installation is complete, plug VTO and switch to power, and wait about 2 min until VTO and VTH boot up. Log in web interface of VTO. 4.3.1 VTO WEB Config: In web, input VTO IP and input account/password: admin/admin. Then Go to Local Config and set Video Format to WVGA.
Page 16
Figure 4- 19 Go to LAN Config, check Group Call, then click on OK. Reboot VTO. See Figure 4- 20. Figure 4- 20 Under group call, VTH is classified into main VTH, extension. There can have a maximum of 1 main VTH and 5 extensions.
Page 17
Product Info, click on Master button to switch to extension. For example, set room no. to 102-1. Input master IP in corresponding field. When you are done, extension will sync call info with main VTH’s VTO. See Figure 4- 23.
Appendix Toxic or Hazardous Materials or Elements Toxic or Hazardous Materials or Elements Component Name Cr VI PBDE Circuit Board ○ ○ ○ ○ ○ ○ Component ○ ○ ○ ○ ○ ○ Device Case ○ ○ ○ ○ ○ ○...