Product Name : Wattman (HPM-100A)
AD Power Co., Ltd
- 1 -

Advertisement

loading

Summary of Contents for AD Power Wattman HPM-100A

  • Page 1 Consumption/Standby Power Meter Manual Product Name : Wattman (HPM-100A) AD Power Co., Ltd - 1 -...
  • Page 2: Table Of Contents

    CONTENTS 1. Product Introduction -------------------------------------------------------- 3 2. Power Measurement -------------------------------------------------------- 7 3. Electric Energy Measurement --------------------------------------------- 7 4. PC Communication Method ----------------------------------------------- 9 5. Functions of “Hold” and the Backlight ------------------------------- 10 6. Others ---------------------------------------------------------------------------- 10 - 2 -...
  • Page 3: Product Introduction

    1. Product Introduction Wattman (HPM-100A)isaconsumption/standby power analyzer and a practical and economical handheld-type wattmeter. It enables the measurement of the power consumption of home appliances and business equipment with not greater than a 9mW~3.75kW power consumption, in a Plug & Play way, thus allowing easy and simple operation by any user. It also enables the easy conversion of electric power usage data into electric charge and amount of CO2 emission values.
  • Page 4 Voltage AC 90V ~ 260V Within an AC 10~15A range, there should be at-least-10-minute intervals and each measurement should be done within 30 seconds. With a Current less-than-10A current, the measurements can be conducted for a longer time. ※ When measuring a continuous 10A or higher current, thebuilt-infuse can be disconnected. The measurement should thus be accomplished within a maximum of 30 seconds.
  • Page 5 Figure 1. Front view and button of HPM-100A ⊙ Function of the Push Buttons Push Button Function LIGHT LCD backlight on/off HOLD Temporarily pauses the measurement value In the accumulative electric energy mode (Wh), with no accumulation being operated, press this button for 3 seconds and it will be reset when you hear the beeping sound.
  • Page 6 ※ Warning: All the electric-energy-related buttons (Wh CLR, Wh TIME SET, Wh RUN/STOP, COST SET) can be operated in the accumulated electric energy mode (Wh). ⊙ LCD Display 1. Input AC : Wattman is for AC use only. 2. Temporary Pause : Use when pausing the measurement value. 3.
  • Page 7: Power Measurement

    2. Electric Power Measurement First, make sure that the supply voltage (source voltage) and the voltage rating of the equipment to be measured are identical. Wattman enables the simultaneous measurement of the voltage, electric current, electric power, and frequency values. It basically enables the measurement of a 9mW~3.75kW range (consumption and standby power measurement).
  • Page 8 TIM E SET 2. Press the button for accumulation time setting from 1 hr up to 24 hr (00.hr: unlimited accumulation). RUN/STOP 3. Press the button and the accumulation will be conducted for the duration of the set time. 4. While accumulation is in progress, pressing the RUN/STOP button will stop the accumulation process.
  • Page 9: Pc Communication Method

    4. PC Communication Method 1. HPM-100A is compatible with RS-232C communication. 2. The GUI PC program will be provided free of charge. It can also be downloaded from the homepage. 3. The basic transmission protocol is as follows: (Transmission protocols can be confirmed from a hyper terminal.) - Cable supply for data communication (with charge) (1) Communication Port: Connect to a created port in the case of a serial communication port or a USB cable.
  • Page 10: Functions Of "Hold" And The Backlight

    UNIT(data at the decimal point) UNIT 1 UNIT 2 UNIT 3 UNIT 4 UNIT 5 UNIT 6 UNIT 7 Volt 0.000 V 00.00 V 000.0 V Ampere 0.000 mA 00.00 mA 000.0mA 0.000A 00.00A 000.0A Watt 0.000 W 00.00 W 000.0 W 0.000 kW 00.00 kW...
  • Page 11 4. It is much safer to have the product repaired by the company’s service personnel even beyond the warranty period. (A/S Service Center Contact No.:82-32-234-3794) Accessories: Manual for users, portable bag, cable supply for data communication use (with charge) AD Power Co., Ltd. Gyeonggi-do Bucheon-si Wonmi-gu Yakdae-dong 193 High-Tech Measuring Device Research Complex 402, Room 1304 E-mail: adc@adpower21.com...