Download Print this page

Opiz OP-D7D5R User Manual page 2

Direct-call door station

Advertisement

VIEW
1. Front view
2. Rear view
Ⅱ.
FUNCTIONS
1. Two way communication
2. Unlock
3. One house one button
4. Transmit video image
Ⅲ.
OPERATION
Calling: press " Call " button to call the indoor phone and talk with the householder
of the indoor phone. The householder can unlock the door by pressing " Unlock "
button.
① Screws
② MIC
③ Camera
④ Speaker
⑤ Call button
ID card reader
Resident monitor connection connector
⑦ Power connection(Red: + Black: -)
⑨ Door release connection wire
5. Back light for keyboard
6. IR CCD camera
7. Visual and non-visual are compatible
- 1 -
Ⅳ.
SPECIFICATIONS
Temperature: -40 ℃
~70 ℃
Relative humidity: 45%~95%
Atmospheric pressure: 86Kpa~108Kpa
Fire endurance rating: IP33
Working voltage: DC12V
Ⅴ.
PROGRAMMING
1. Wire requirements:
(1)If the main line length less than 50 meters, the cross-sectional area should be more than or
equal to 0.3 square millimeter.
(2)If the main line length is 50 to 100 meters, the cross-sectional area should be more than or
equal to 0.5 square millimeter.
(3)If the extension length less than 20 meters, the cross-sectional area should be more than or
equal to 0.15 square millimeter.
(4)If the extension length is 20 to 50 meters, the cross-sectional area should be more than or
equal to 0.3 square millimeter.
(5)Power to door station and station to electronics lock wires, the cross-sectional area should
be more than or equal to 0.5 square millimeter. And length must be less than 15 meters or
should enlarge the area of wires.
2. Programming
VI Video line
AU Audio line/ Unlock line
G Ground line
12V Power line,Connect with expand panel
13.5V Power
supply
Static current: 0.17mA
Working current: 146mA
Camera: Color 420L; B/W 480L
Dimension: 320*125*70mm
N.W: 1000g
Connect with
expand panel
Connect with expand panel
13.5V Power
supply
- 2 -