  • Page 2: Important Instructions

    IMPORTANT INSTRUCTIONS: Read all these instruc�ons before installing or using this heater. Indeeco is interested in the safe opera�on of its equipment. All wiring to this equipment must be connected to the electrical source in strict accordance with National Electrical Code (N.
  • Page 3: Installation

    INSTALLATION: All wiring to this equipment must be connected to the electrical source in strict accordance with National Electrical Code (N. E. C.) and local codes having jurisdic�on. Before installing this equipment, the user must be aware of the safety requirements as specified by the National Board of Fire Underwriters.
  • Page 4 Fig. 2 – WALL MOUNTING Once the heater is mounted to the wall, posi�on the heater to the desired angle between 20° and 45° downward from the horizontal, limited by the slot length. Tighten the two posi�oning bolts to secure the heater. WARNING! Risk of fire.
  • Page 5 Fig. 3 – CEILING ONLY VERTICAL MOUNTING POSITIONING Fig. 4 – CEILING MOUNTING VERTICAL...
  • Page 6 Fig. 5 – CEILING MOUNTING ANGLED AWAY FROM VERTICAL SURFACE Fig. 6 – CEILING MOUNTING ANGLED TOWARDS VERTICAL SURFACE...
  • Page 7 FOR PROTECTED AREA MOUNTING: A Protected Area is defined as “Located in an area that is par�ally protected from the effects of weathering.” Typical protected areas would be the underside of a pavilion with a roof, garage port, and the like. FOR PROTECTED AREA WALL MOUNTING: Adhere to all requirement for Wall Moun�ng listed above.
  • Page 8 FOR PROTECTED AREA CEILING MOUNTING: Adhere to all requirement for Ceiling Moun�ng listed above. Addi�onally: Do not install the sec�on closer than 12 inches to edge of overhang of roof. The heater needs to be installed in a posi�on such that it is protected from rain, snow, and similar outdoor wet areas.
  • Page 9 For supply connec�ons use the wire size (or larger) as directed by the chart below. All wires must be suitable for at least 90°C (194°F). SUPPLY CONNECTIONS 120 VOLT 208/240 VOLT MODEL NUMBER AWG. WIRE SIZE AWG. WIRE SIZE STT-U18-1091B STT-U18-1330B STT-U18-1767B STT-U18-2161B...
  • Page 10: Wiring Diagram

    WIRING DIAGRAM...
  • Page 11: Operation

    OPERATION: Heaters must be properly installed before use. Do not operate heaters without all covers in place. No user maintenance is needed for heaters. Any other servicing should be performed by authorized service personnel. During produc�on, the hea�ng element of this unit may have absorbed moisture. The first �me your heater is turned ON, it may smoke/steam while the moisture is released.
  • Page 12: Warranty

    Ordinary wear, accident, improper installation, or maintenance Alterations made to equipment in any way Indeeco shall not be liable for any losses or damages, including but not limited to incidental or consequential damages, suffered or incurred because the equipment proves to be defective either upon installation or during its operation or use.