USER & OPERATING MANUAL
UTL
UTL
GAMMA +
GAMMA +
• Controller based design, Pure Sine Wave, Built in rMPPT
Charge Controller.
• Multi-colour LCD Display.
• Freq.:- Available - 50Hz & 60Hz.
• Charging Multi Stage (Bulk, Absorption & Float)
• Solar Priority of load & battery charging.
• Preference to Solar Power over Grid Power.
• Pure sine wave output.
• Protections : RBP, RSPV, OVL, BL, OBC, SC, IHV & ILV.
• Compatible with DG as an input Source.
• Compatible with IT Load.
• Compatible with SMF, Gel & Tubular Batteries.
• Priority Selection - PCU, Smart & Hybrid for Saving Energy
and Money.
SOLAR
SOLAR
SOLAR
22
22
22 22
ISO
ISO
14001 : 2015
9001 : 2015

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the GAMMA+ and is the answer not in the manual?

Questions and answers

NIVESH
March 18, 2025

How reset setting utlgama+ 12 volt

1 comments:
Mr. Anderson
March 18, 2025

To reset the settings on the UTL GAMMA+ 12 Volt, follow these steps:

1. Enter calibration mode.
2. Change the required parameters by following the procedure (1.1, 1.2 & 1.3).
3. To exit calibration mode, press and hold the SMT switch for 10 seconds.
4. A beep will indicate that the system has exited calibration mode.

This will reset the settings based on the changes made.

This answer is automatically generated

KISHOR KUMAR SINGH
June 7, 2025

Gamaplus inverter 1/24 ke kard ka kya kimat hai.

Summary of Contents for UTL GAMMA+

  • Page 1 USER & OPERATING MANUAL SOLAR SOLAR SOLAR 22 22 GAMMA + GAMMA + • Controller based design, Pure Sine Wave, Built in rMPPT Charge Controller. • Multi-colour LCD Display. • Freq.:- Available - 50Hz & 60Hz. • Charging Multi Stage (Bulk, Absorption & Float) •...
  • Page 2: Table Of Contents

    S.No Contents Page Safety Installation System Handling Switch Function Flow Chart Selection of Working Modes Display Panel Details Scrolling Display System Error Description Display Back Light Color Description Factory Setting Procedure Calibration Procedure Block Diagram Flow Chart System Description Technical Specification Operating Instructions Preventive Maintenance Troubleshooting...
  • Page 3: Safety

    1. SAFETY 1.1. General Read safety notes carefully and thoroughly to ensure its correct installation and operation. Save this manual properly. Installation, maintenance & repair of the equipment should be undertaken by trained, experienced and authorized service person. The handling, installation & maintenance of the battery associated with this equipment, must be done in accordance with the instructions &...
  • Page 4: Installation

    Avoid installing the PCU in location under direct sunlight, running water, or excessive humidity. Routine preventive check shall be done.. Store the Solar PCU in its original Packing. Ensure the arrow on the box is pointing vertically upward direction. Store it in dry location. Storage temperature must be between-10 to 70°C Suitable handling equipment shall be used for handling of PCU.
  • Page 5: System Handling

    ● Load will run on Inverter Output. ● After Connecting Mains Supply switch ON the GRID. 2.4 Storage When the System is not installed immediately, it must be stored carefully in vertical position, as indicated on the packing and conserved in a dry and sheltered room.
  • Page 6 3.1 System (Front View) 305.5 mm 3.2 System (Back View) 305.5 mm BATT. REV./ SPV REV. FUSE BLOWN OUTPUT FUSE 1Ø 220V~; 50/60Hz SOLAR DC FUSE + VE 15-45V Max _ _ __ BATTERY INPUT Model No Serial No Capacity DC Volt Nominal Input Page: 4...
  • Page 7: Switch Function Flow Chart

    4. SWITCH FUNCTION FLOW CHART SWITCHES DOWN PRESS 1-TIME HOLD/SAVE/RESUME SYSTEM ON/OFF SWITCHES ENABLE IT MODE DISABLE SMF/ CHANGE TUB. ENABLE BOOST PRESS 3-TIMES CHG. DISABLE ENABLE GRID CHG. DISABLE SWITCHES Factory Setting Reset PRESS SWITCH Calibration Menu COMBINATION FOR 15SEC. PCU/Smart/Hybrid Mode Selection SWITCHES Exit from Calibration...
  • Page 8 IT Mode LED :- On Pressing Switch 3 times, IT Mode LED will solid glow shows IT Mode is Enabled. On again pressing this switch 3 times this LED will get OFF shows that IT Mode is disable. SMF/TUB :- On Pressing Switch 3 times, SMF/TUB LED will get OFF shows TUB Battery is Selected.
  • Page 9: Selection Of Working Modes

    5. SELECTION OF WORKING MODES (HYB/SMT/PCU) View - 1 for 15 sec. to enter Now on pressing switch in to working modes window. This window shows Smart mode is selected as working mode of the system. To select any of the working mode out of HYB/SMT/PCU, we need to press switch.
  • Page 10: Display Panel Details

    6. DISPLAY PANEL DETAILS The Display panel provides all the information related to operating status & electrical parameters. LCD Display Under/Over voltage for Array & Battery, Array & Battery reverse Protection polarity, Output Overload, Short circuit, Over Temperature. System ON, IT-Mode, SMF/TUB, Grid Charging Disable, Indication Boost Charging, Over Heat, Mains Low/High, DG Mode, &...
  • Page 11 View - 3 34.7 PCU Mode, SPV Voltage 34.7V. View - 4 a 2.0 PCU Mode, Solar Current is 2.0A. View - 5 PCU Mode, Solar Instantaneous Power is 0.1Kwh. MAINS ON View - 6 PCU Mode, Mains/Grid/Input Voltage is 250V MAINS ON View - 7 50.0...
  • Page 12: System Error Description

    8. SYSTEM ERROR DESCRIPTION View - 1 Inverter Open Circuit Error View - 2 Grid Charger Open Circuit Error View - 3 NTC Open Circuit Error View - 4 Feed Back Transformer Error View - 5 Fuse Blown/Zero Crossing Error FUSE/MCB TRIP View - 6 Relay Fault Error...
  • Page 13: Display Back Light Color Description

    View - 7 GRID Frequency Out 9. DISPLAY BACK LIGHT COLOR DESCRIPTION LED BACK LIGHT COLOR DESCRIPTION Protection (SOLID GLOW) Error (E1 to E8) (BLINK) LIGHT ORANGE When Mains Present (SOLID GLOW) GREEN When Solar is Present (SOLID GLOW) ORANGE When SPV + Mains Present (SOLID GLOW) LIGHT GREEN...
  • Page 14: Factory Setting Procedure

    10. FACTORY SETTING PROCEDURE View - 1 After Pressing Switch Simultaneously for 15 sec. First window will Appear as shown in Fig. which shows Factory Setting Mode. View - 2 This window shows Factory Setting finally saved. 11. CALIBRATION PROCEDURE View - 1 Simultaneously After Pressing Switchs...
  • Page 15 View - 1.2 multiple times to Now on pressing switch BATT. L11.5 Increase Battery Low Voltage set Point maximum upto 11.5V. View - 1.3 BATT. battery low voltage Now on pressing switch H16.5 save and go to battery high set point window. View - 2 After saving battery low set point you will get battery high set window.
  • Page 16 View - 4 After saving battery charging voltage through MAINS solar we will get battery charging voltage through BATT. mains window. In this window you can get by 13.5 default 13.5V(float & boost) and variable voltage range 13.5-14.2V. For Tubular Battery by default 14.5V(boost), 13.8V(float) and variable range 13.5-15V(Boost), 13-14.2V(float).
  • Page 17 View - 8 MAINS For changing the frequency. Follow previous procedure(1.1, 1.2 & 1.3). View - 9 After saving frequency we will get main MAINS reconnect voltage window. In this window you can get variable voltage reconnect range 11-12V. 1 1.8 After change parameter follow previous procedure (1.1, 1.2 &...
  • Page 18: Block Diagram

    12. BLOCK DIAGRAM SPV/Solar DC/AC DC/DC Output/ Module Converter Converter Load Mains/Grid/Input Battery 13 FLOW CHART 13.1 Hybrid Mode Load On Batt GRID Load on Grid START GRID CHG. on Grid CHG. ON PV GRID Load on Batt.+PV Load on Grid GRID CHG.
  • Page 19 13.2 Smart Mode Page: 17...
  • Page 20 13.3 PCU Mode Page: 18...
  • Page 21: System Description

    14. SYSTEM DESCRIPTION PCU is single phase output, Solar Inverter System. In normal (Hybrid) mode, PCU operates from battery or array power source and produces single phase AC output to fulfill the load requirement MPPT based array charger, supplies the DC power for battery charging as well as for the inverter.
  • Page 22: Technical Specification

    15. TECHNICAL SPECIFICATION Parameters System Rating 1kVA Operating DC Voltage Switching Element Mosfet Charger Topology Boost Mosfet Setable Range Grid Nominal Grid Voltage 230V Battery Low Cut - 0.3V Battery Low Buzzer 10.8V Battery Low Cut 10.5V 10-11.5V 16.5-17.5V Battery High Cut 16.5 11-40A SPV Charging Current...
  • Page 23: Operating Instructions

    16. OPERATING INSTRUCTIONS To Start the System ● Connect earth to the system. ● Check tightness of all power terminals outside of the Cabinet. ● Ensure Battery voltage and Polarity and then connect it to the System. ● Ensure SOLAR array voltage & polarity and then connect it to the system. ●...
  • Page 24: Troubleshooting

    18. TROUBLESHOOTING PROBLEM POSSIBLE CAUSE RESOLUTION In day Hours with Array voltage absent Check Array supply good solar Array is at extremely Check Array supply low/high voltage radiation, low / high voltage condition Condition Solar PCU is running on battery Solar PCU Overload Check load condition Battery deteriorated...
  • Page 25: Warranty Card

    Page: 23...
  • Page 26 upsinverter.co m upsinve rter.com HEA VY DUT Y BAT TER 36 Mon ths Warr anty For Sola r Use IND IA MA DE IN FUJIYAMA POWER SYSTEMS PVT. LTD. 53A/6, Rama Road Ind. Area, Near Sat Guru Ram Singh Marg Metro Station, Near NDPL Grid Office, Delhi - 110015. For Any Support: +91 9250 885 885 E-mail: service@utlups.com, Website: www.upsINVERTER.com Manufacturing Unit...