Summary of Contents for WarmingTends HMLS60-NG

  • Page 1 DESIGN CERTIFIED CROSSFIRE SYSTEMS HMLS60-24V LP/NG DMLS60-3V LP/NG MLS60 LP/NG   1  ...
  • Page 2 WARNING: FOR OUTDOOR USE ONLY Improper installation, adjustment, alteration, service, or maintenance can cause injury or property damage. Read the installation, operating, and maintenance instructions thoroughly before installing or servicing this equipment. Warning: •Do not store or use gasoline or other flammable vapors and liquids in vicinity of this or any other appliance.
  • Page 3: General Info

    1) General Info Instructions are also available at www.warming-trends.com Please carefully follow the instructions in this manual to prevent personal injury or property loss. Instructions are updated as needed. It is the installer’s responsibility to periodically review instruction for applicable updates.
  • Page 4 installation. ● Natural Gas Fire Pit: Supply Pressure: Minimum: 3.5” W.C.; Maximum: 5.0” W.C. Outlet Pressure: 3.5” W.C. ● LP Gas: Supply Pressure: Minimum: 10.0” W.C.; Maximum: 11.0” W.C. Outlet Pressure: 10.0” W.C 2) Location Warning: All fire pits, match lit kits, spark ignition, safety pilot and electronic ignition systems are designed and intended for outdoor use only.
  • Page 5 3) Construction of the Enclosure Warning: For electronic ignition models there must be an electrical shut off ( wall switch or breaker ) on the exterior of the fire pit or on adjacent wall to allow for emergency shutdown and maintenance. Verify correct 110VAC or 24VAC Supply.
  • Page 6: Fire Pit Installation

    4) Fire Pit Installation ***We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping. Warning: We suggest that our products be installed by professionals that are locally licensed by the authority having jurisdiction in gas piping. Warning: We suggest that our products be serviced annually by a professional certified in the US by the National Fireplace Institute (NFI) as NFI Gas Specialists.
  • Page 7 testing. Light fire pit. It may take several cycles to purge air from the • lines. For electronic ignition models apply proper 110VAC or 24 VAC. Once fire pit is lit perform leak test on all gas connections. Repair • as needed.
  • Page 8 Lava Rock Only Application 1) Install your fire pit per instructions. 2) Apply lava rock ONLY deep enough to cover burner and pan less than 1” below crossfire burner jets. For Electronic Ignition 3) PILOT ASSEMBLY SCREEN: Do not cover pilot assemble screen or opening with lava rock or glass.
  • Page 9: Parts List

    Decorative Glass Application 1) Install your fire pit per instructions. 2) Fill Pan with glass. Cover Burner with 1/8 to .” of glass. Do not over fill with glass. All LP installations must be checked for back pressure with media installed. Failure to do so may result in personal injury or property damage.
  • Page 10 Fireplaces and Fire Pits   Model Number Description CFP60 Fireplace Insert – Grates and Logs included MFP60 Fireplace Insert – Grates and Logs included FBI42 Fireplace Box Insert 42” FP6060 Fireplace Kit 60” x 60” x 24” Square FT3636 36” OD x 18” H Square Fire Pit FR4830 48”...
  • Page 11 PXN42 Parallax Fire Table 42” Square, Nova PXP42 Parallax Fire Table 42” Square, Provance PXR42 Parallax Fire Table 42” Square, Lava Red PXT42 Parallax Fire Table 42” Square, Tuscan SIMP24 24” Simplicity Fire Bowl SIMP38 38” Simplicity Fire Bowl CSIMP36 36”...
  • Page 12: Installation

    Model Number HMLS60-*NG Honeywell, Natural Gas HMLS60-*LP Honeywell, Propane Gas DMLS60-*NG Dexen, Natural Gas DMLS60-*LP Dexen, Propane Gas MLS-60 NG Match Lit, Natural Gas MLS-60 LP Match Lit, Propane Gas CFB-60-*NG Crossfire, Natural Gas CFB-60-*LP Crossfire, Propane Gas * represents ignition system type: 3V, 3VIK, 24V, 24VIK, MLS •...
  • Page 13: Manual Lighting Instructions

    Warning: Wind and gusty conditions will affect the flame in an unpredictable manner. If conditions exist that are not safe for patrons turn the fire pit off. Warning: Do not use fire pit if any part has been submerged under water.
  • Page 14: To Turn Off Gas Appliance

    Check for good flame and gas leaks Add media and repeat Warning: If the flame will not stay lit after several tries, turn the key valve to the OFF position and call your service technician or gas supplier. 5. Never leave fire pit unattended by an adult. TO TURN OFF GAS APPLIANCE 1.
  • Page 15: Maintenance

    9) Maintenance Warning: Any guard or protective device removed for servicing must be replaced prior to operating the fire pit. Warning: Installation and repair should be done by a qualified service person. Fire pits should be inspected prior to use and at least annually by a qualified service person.
  • Page 16: Warranty

    No Main Burner (Pilot Lights) 1. Gas Pressure Improper Confirm proper gas pressure (Section 1) 2. Small Pilot Flame Remove pilot head and clean orifice. ( Section 8) 3. Dirty Thermocouple Clean using soft brush (Section 8) 4. Crossfire Burner Obstructed Confirm no debris or water in burner (Always cover fire pit!) 5.
  • Page 17 HMLS60 with LP or NG with Honeywell Electronic Spark Ignition System   17  ...
  • Page 18 DMSL60 with LP or NG with Dexan 3 Volt Battery or 110 Ignition System   18  ...
  • Page 19 MLS60 with LP or NG Regulator   19  ...
  • Page 20 System Tags and Markings   20  ...
  • Page 21   21  ...
  • Page 22   22  ...
  • Page 23   23  ...