3) CONFIGURE MODULE VIA COMMAND LINE INTERFACE
To access the Command Line Interface (CLI), connect the TM3 RS-232 Serial Console
Port to the COM port of a computer equipped with terminal emulation software such as
HyperTerminal. The Console Port (DCE) is a mini DIN-6 female connector which can be
changed to a DB-9 connector with the included adapter. The TM3 Console Port is a standard
RS-232 asynchronous serial interface.
Start HyperTerminal and select the correct COM Port in the HyperTerminal "Connect To:"
window. Set the serial port to the following:
Bits Per Second
57,600
Data Bits
8
Stop Bits
1
Parity
NONE
Hardware Flow Control
NONE
Once connected, press <ENTER> to bring up a command line prompt on the attached PC.
A new TM3 module does not have a password, and will skip the Password Entry screen and
go straight to the Management Options screen. If a password has been set, the Password
Entry screen will be displayed. Type the password and press <ENTER>, the TM3 will respond
with the Management Options screen.
The CLI interface enables detailed configuration of the module.
4) VERIFY OPERATION
Once the module has been installed and configured per steps 1 - 3, verify the module is
operational by viewing the LED indicators.
LED Function
Color
"Legend"
Power
Green
"PWR"
P1 Link Activity
Green
"100"
P1 Link Activity
Green
"1000"
P1 Link Activity
Green
"100" and "1000"
Test/Alarm
Green
"Tst/Alm"
Management Mode
Green
"Msr/Slv"
P2 Link Activity
Green
"100"
P2 Link Activity
Green
"1000"
P2 Link Activity
Green
"100" and "1000"
Figure 5: LED Indicators
Omnitron Systems Technology * 38 Tesla * Irvine, CA 92618
949.250.6510 tel * 949.250.6514 fax * www.omnitron-systems.com
OFF State
ON/Blinking State
No power
ON: Module has power
ON: Port linked at 100M
Port not linked at 100M
Blinking: Data activity
ON: Port linked at 1000M
Port not linked at 1000M
Blinking: Data activity
ON: Port linked at 10M
Port not linked at 10M
Blinking: Data activity
Reserved
Reserved
ON: Master (normal)
Slave Mode
5 Hz Blinking: Secure Slave
ON: Port linked at 100M
Port not linked at 100M
Blinking: Data activity
ON: Port linked at 1000M
Port not linked at 1000M
Blinking: Data activity
ON: Port linked at 10M
Port not linked at 10M
Blinking: Data activity
040-2420T-002C 06/13
iConverter TM3 Transport Module
Quick Start Guide
PRODUCT OVERVIEW
This document describes the basic installation and configuration of the TM3 Transport
module.
iConverter
The
Modular T1/E1 Multiplexer transports up to sixteen T1/E1 circuits and
10/100/1000 Ethernet over a fiber transport link or CWDM channel. This flexible and scalable
iConverter
system is comprised of an
TM3 fiber transport module, and one or more
4xT1/E1 MUX modules installed in a 2, 5 or 19-module chassis.
For the complete User Manual on this product, access Omnitron's secure download site
and request access.
http://www.omnitron-systems.com/login.php
INSTALLATION PROCEDURE
1) Configure DIP-Switches
3) Configure Module via Command Line Interface
4) Verify Operation
1) CONFIGURE DIP-Switches
DIP-SWITCH BANK 1
The function of DIP-switch Bank 1 is outlined in Figures 1 and 2 below.
Switch
Down (Default)
Up
AN:
Man:
1
P1 Auto-neg.
P1 Manual
AN:
Man:
2
P2 Auto-neg.
P2 Manual
1000:
10-100:
3
P2 1000Mbps
P2 10 or 100Mbps
100:
10:
4
P2 100Mbps
P2 10Mbps
FDX:
HDX:
5
P2 Full-Duplex
P2 Half-Duplex
6
7
Link Modes (see Figure 2)
8
Figure 1: DIP-switch Bank 1
SW6
SW7
SW8
Link Mode
Down Down Down
Link Segment (LS)
Up
Down Down
Link Propagate (LP)
Remote Fault Detect + Link
Down
Up
Down
Segment (RFD+LS)
Remote Fault Detect + Link
Up
Up
Down
Propagate (RFD+LP)
Down Down
Up
Symmetrical Fault Detect (SFD)
Asymmetrical Link Propagate Port
Up
Down
Up
1 to Port 2 (ALP P1 P2)
Asymmetrical Link Propagate Port
Down
Up
Up
2 to Port 1 (ALP P2 P1)
Asymmetrical Link Propagate Port
Up
Up
Up
1 to Port 2 + Port 1 Remote Fault
Detect (ALP P1 P2 + P1 RFD)
Figure 2: Link Mode Settings