Introduction 9.トラブルシューテ ィング Thank you very much for purchasing the CC monitor DTY-CMH-01. 現象 確認して く だ さい In handling this device, read this Owner’s Manual carefully, and always handle 電源を入れて最初の5分間は測定の準備時間です。 5分間 電源を入れて表示が出た it with due caution and correct operation. Keep this manual in a safe place so はLEDが順次点灯...
Page 13
Always carefully read the Owner’s Manual and understand the content before ・Do not use tape or nails to fix the power cord in place. performing operations. Please be aware that Koganei cannot be responsible for ・Do not perform wiring that could cause tripping or other accidents.
Page 14
・Locations where radiant heat, etc., results in heat accumulation. ●Do not wipe the device with benzene, thinner, or a wet cloth, etc. ※ Koganei cannot be responsible if these items are not properly observed. ●This product is a Class 1 laser product regulated under JIS C 6802 (2005).
3. Product Overview Bottom of the body The CC monitor DTY-CMH-01 is a device that uses the light scattering principle to simply detect and display the cleanliness level. In addition, it can use Ethernet communication to collect data on a personal computer. Output...
Page 16
Rear of the body Body display area Name Function Parts Functions When an alarm output is issued, the open collector output Red LED lights continuously display the current Alarm output Level display turns on. Can be used as an external warning buzzer or a cleanliness level.
5-1. Installation method Mount with a vertical surface and maintain the product’s top and down direction. DTY-CMH-01 can be mounted with 4 possible methods. Select the 1 2 Alarm output mounting method that is optimum for your application conditions.
6. Operation Method Output Characteristics 6-1. Detection Upper limit 1) Install the DTY-CMH-01 in the desired measurement location. (See p.#1 , “5-1. Installation Method.”) 2) Supply power to the DTY-CMH-01. Middle 3) The first 5 minutes after switching on the power is preparation time to Lower limit measure.
2) Installation of Device Installer Ver4.1.0.9 automatically stop being turned on. In order to set the IP address for DTY-CMH-01, the LANTRONIX Device Installer Ver4.1.0.9 must be installed. 3) If the particle density exceeds the setting value and then falls back below the setting value without any action being taken, the buzzer, LED, and external Device Installer Ver4.1.0.9 can be downloaded from the Nisshin Systems Co.,...
LD monitor: Normal =0, Abnormal=1 (Shows D (1 byte) whether semiconductor laser is normal or abnormal.) 5) Use the same procedure to set the IP addresses for all of the DTY-CMH-01 Data format: ASCII units. When setting is completed, close Device Installer Ver4.1.0.9. That completes the IP address settings.
Equivalent of ISO class 5 to ISO class 8 Measurement method Light scattering method Detectable particle size 0.3 μm or larger Display method LED display of cleanliness levels set by Koganei (210 [8.268]) 200 [7.874] 10-stage level display from LEVEL 100 to LEVEL 100,000 5 [0.197] 190 [7.480]...
KOGANEI CORPORATION change the alarm setting, OVERSEAS DEPARTMENT Press the SET button. the change is not 3-11-28, Midoricho, Koganei City, Tokyo 184-8533, Japan activated in the TEL: 042-383-7271 FAX: 042-383-7276 operational setting. Alarm buzzer will not stop. Press the RESET button.