I N S T A l l A T I O N
E S 8 4 / 8 6 S E r i E S
Electric Strikes
The ES84/86 electric strikes include two profiles:
• The ES84 (Low Profile) version features a 1-1/16"D body, accepts 1/2" or 5/8" latch projection, and is designed for narrow stile
(i.e., aluminum) frames.
• The ES86 (Standard Profile) version features a 1-3/16"D body that accepts 3/4" latch projection.
NOTE: Universal packaging (faceplate 'U') includes faceplate sizes 86S4, 86S4S, and 86S7.
1. Determine the vertical centerline of the door lock face and
the horizontal centerline of the latch.
IMPORTANT: When determining the horizontal centerline
observe the following:
FOR MORTISE LOCKS: Align the angled ramps of the lip
bracket with the deadlock trigger of the mortise latch.
FOR CYLINDRICAL LOCKS: Align the center of the latch with
the center of the strike opening.**
2. Transfer both the horizontal and vertical centerlines to the
doorframe.**
3. Prepare the doorframe for cutting as shown in the
appropriate drawing.
Aluminum Frames 1-3/16"D
Modular ES86 FSV or ES86 FSV LKM or
ES86 U assembled with 86S4 faceplate
A
1-1/4
1.250
31.75
b
4-7/8
4.875
123.83
C
3-3/8
3.375
85.73
D 1-3/16
1.188
30.16
E
3/8
.375
9.53
F
1/8*
.125*
3.18*
G 1-11/16
1.688
42.86
Vertical
Vertical Vertical
Vertical Centerline
X
C/l
C/l
C/l
of Door**
Door
Door
Door
R
5/32
0.156
3.97
K
4-1/8
4.125
104.78
M
12-24
NOTE: Specifications subject to change without notice.
*
Dimension F is measured from face of mounting tab to face of frame.
**
Dimension X on the drawing is determined by the vertical centerline of the door. If the latch incorporates a deadlocking pin additional steps will be
necessary to ensure proper operation of the deadlocking pin. Measure the thickness of the deadlocking pin and add this thickness to Dimension X to
relocate the vertical centerline an appropriate distance on the frame.
ISES84/86
USA: DORMA DRIVE, DRAWER AC, REAMSTOWN, PA 17567 PHONE: (800) 523-8483 (717) 336-3881 FAX: (717) 336-2106
08281220
Instructions
C L
X
M
R
E
D
G
C L
F
M
K
C
B
G
A
© 2015 DORMA
EMAIl: archdw@dorma-usa.com WEbSITE: dorma-usa.com
4. If required, install the 'no weld' mounting tabs per page 4.
5. Attach the strike faceplate to the lip bracket with the self-
tapping screws provided. (It may be desirable to leave
these screws slightly loose to facilitate insertion into the
doorframe.
6. Connect the incoming wiring from the power supply (see
wiring instructions).
7. Install the door strike in the doorframe using the screws
provided.
Aluminum Frames 1-1/16"D
Modular ES84 FSV or ES84 FSV LKM or
ES84 U assembled with 86S4 faceplate
A
1-1/4
1.250
31.75
b
4-7/8
4.875
123.83
C
3-3/8
3.375
85.73
D 1-3/32
1.094
27.78
E
3/8
.375
9.53
F
1/8*
.125*
3.18*
G 1-11/16
1.688
42.86
Vertical
Vertical Vertical
Vertical Centerline
X
C/l
C/l
C/l
of Door**
Door
Door
Door
R
5/32
0.156
3.97
K
4-1/8
4.125
104.78
M
12-24
C L
X
M
R
E
D
G
C L
F
M
K
C
B
G
A
PCN14085
R09/15TG

Advertisement

loading
Need help?

Need help?

Do you have a question about the ES84 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Dorma ES84 Series

  • Page 1 Measure the thickness of the deadlocking pin and add this thickness to Dimension X to relocate the vertical centerline an appropriate distance on the frame. © 2015 DORMA ISES84/86 PCN14085 USA: DORMA DRIVE, DRAWER AC, REAMSTOWN, PA 17567 PHONE: (800) 523-8483 (717) 336-3881 FAX: (717) 336-2106 08281220 R09/15TG EMAIl: archdw@dorma-usa.com WEbSITE: dorma-usa.com...
  • Page 2 ES84/86 Series Installation Instructions (Continued) Aluminum & Wood Frames, 1-3/16” D Aluminum & Wood Frames, 1-1/16” D Modular ES86 FSV or ES86 FSV LKM assembled Modular ES84 FSV or ES84 FSV LKM assembled with 86S5 faceplate with 86S5 faceplate 1-1/8 1.125 28.58 1-1/8...
  • Page 3 ES84/86 Series Installation Instructions (Continued) Aluminum & Wood Frames, 1-3/16” D Aluminum & Wood Frames, 1-1/16” D Modular ES86 FSV or ES86 FSV LKM or Modular ES84 FSV or ES84 FSV LKM or ES86 U assembled with 86S7 faceplate ES84 U assembled with 86S7 faceplate 1-7/16 1.438 36.51...
  • Page 4 ES84/86 Series Installation Instructions (Continued) Mounting Tab Kit instructions Mounting Tab Mounting tab kit is for use with aluminum and steel frames that (2 incl.) do not have factory installed mounting tabs for electric strike installation. 1. Prepare the frame as shown in the approximate drawing. Fasten the mounting tab to the faceplate of the strike, selecting the appropriate shims for the installation.
  • Page 5: Wiring Instructions

    ES84/86 Series Installation Instructions (Continued) Fail Unlocked Wiring instructions Rotate the adjustment screw so the dimple is fully rotated NOTE: Overheated or Burnt Coils caused by incorrect input to opposite the faceplate side of the strike (fully counter voltage / wire harness combinations are not covered under clockwise).
  • Page 6 Confirm that the keeper is closing properly and that the lever in functioning properly the strike cavity is operating freely. © 2015 DORMA USA: DORMA DRIVE, DRAWER AC, REAMSTOWN, PA 17567 PHONE: (800) 523-8483 (717) 336-3881 FAX: (717) 336-2106 EMAIl: archdw@dorma-usa.com WEbSITE: dorma-usa.com...

This manual is also suitable for:

Es86 seriesEs86 fsvEs86 fsv lkmEs86 u86s4