  • Page 1 TAGTEMP Data Logger User Manual ABUS TECHNOLOGIES INC.
  • Page 2  All rights reserved.  ABUS gives no warranty of any kind with regard to this manual, including, but not limited to, fitness for a particular purpose.  If any question arises or errors are found, or if any information is missing from this manual, please inform your supplier or inform at info@abustek.com.
  • Page 3: Table Of Contents

    2. Acquisition Field 3. Start Loggings Field 4. Stop Loggings Field 5. Channels Field 6. Palmtop User 5. Operation 1. Offloading Data 2. Visualization Data 3. Palmtop User 6. Maintenance 1. Observation 2. Troubleshooting 7. Safety Precautions 8. Warranty ABUS TECHNOLOGIES INC.
  • Page 4: Introduction

    TagTemp 1. INTRODUCTION TagTemp is a small portable electronic temperature logger. Its internal sensor measures local environment temperature and logs such values in an electronic memory. Logged data, or ACQUISITIONS, can be later viewed and analyzed on a PC where they can be opened in tabular and graph forms.
  • Page 5: Panel Identification

    3. System failure should always be taken into account when designing a control panel to avoid irreversible damage to equipment or people. 4. Installing RC filters (47R and 100nF, serial) is strongly recommended at contactor coils or any other inductors. ABUS TECHNOLOGIES INC.
  • Page 6: Logchat-Ii

    Configuring, monitoring or downloading data from the logger through LogChart-II requires that the IR-LINK3 communication interface be connected to your PC. This interface is sold separately. The IR-LINK3 interface sends and receives data to/from the logger through infrared signals. ABUS TECHNOLOGIES INC.
  • Page 7: Palmtop User

    Starting the LogChart PalmOS application will display the Recorded Data screen on the Palm from where it is possible to access the logger to change settings and collect data, as well as to access collected data. Recorded Data screen ABUS TECHNOLOGIES INC.
  • Page 8: Configuration

    New configuration parameters defining the operation mode for a new application can be entered. The user can also obtain general information about the device. The fields of the configuration window are described below: Configuration window ABUS TECHNOLOGIES INC.
  • Page 9: General Information Field

    Value: It defines how the value measured will be registered. Options are: Instantaneous: The value logged will be exactly the value measured at each interval defined.  Measurement is taken at the end of the defined interval. The minimum interval between measurements is 1 seconds. ABUS TECHNOLOGIES INC.
  • Page 10: Palmtop User

    More Info: Displays further information on the connected logger, such as model, serial number, version and memory capacity. Settings: Accesses the Settings screen, which allows for modifying the logger configuration. Data Base: Displays the Recorded Data screen listing all the processes stored and processed in the PDA data base. ABUS TECHNOLOGIES INC.
  • Page 11 (log Above) or below (log Below) a temperature setpoint (channel 1). This option is not valid for alarms that have already been set up. By TagTemp button: Starts when the Start/Stop button at the frontal side of the logger is pressed.
  • Page 12 After configuring clocks in the Settings screen, click Apply to send this configuration to the Logger, returning to the Monitoring screen. Sending a new configuration implies the exclusion of all data collected present in the logger memory. ABUS TECHNOLOGIES INC.
  • Page 13: Operation

    Graph window. NOTE: The command Offload acquisitions does not interrupt the process of data logging and reading. Other two windows can be easily opened: General information window and Tables window. ABUS TECHNOLOGIES INC.
  • Page 14 5.1.3 Acquisitions Table Window Data acquired by one or both input channels (user-defined) are displayed in engineering units in a table format. The table displays register number, date/time and the record values. Screenshot showing the acquisitions table ABUS TECHNOLOGIES INC.
  • Page 15: Visualization Data

    To access the conduit options, the HotSync Manager software must be active. Click with the right mouse button on the HotSync Manager in the Windows Taskbar. Select in the drop-down menu the option Custom. Select ABUS LogChart Conduit and click Change. The following window will be exhibited:...
  • Page 16: Maintenance

    2. Make sure there is no physical Communication with the logger fails obstacle blocking infrared Communication signal; 3. Make sure the cable is well connected to the PC port; 4. Make sure the port selected does not present any problem; ABUS TECHNOLOGIES INC.
  • Page 17: Safety Precautions

    10. Power supply should be constant, should not be fluctuating. 8. WARRANTY ABUS provides the original purchaser of this instrument a one (1) year warranty against defects in material and workmanship under the following terms:  The one year warranty begins on the day of shipment as stated on the sales bill.