RTU-COM Compact Outstation Installation and Connection Guide 28.05...
Page 2
482/EC of 20 July 1998-CTR21. appointments, especially to IEC 1010-1. EC-R& TTE directive marking is CE0682X The RTU-COM is classified according to DIN VDE (IEC664-1) 0110: Insulation coordination for equipment within low-voltage systems Installation and application hints Part 1: Principles, requirements and tests.
Mount into a closed cubicle or rack if the Use according to the rules environmental conditions that requires. The RTU-COM module was developed, manu- factured, tested and documented while ob- • Do not obstruct the ventilation for serving the relevant standards. When observ-...
Page 4
RTU-COM Layout and dimension drawings UCR-4XX/10XX 0 1 2 3 SIM card Antenna DIP switch RS232 Power Rxd/Txd Modem System UCR-8DIO 0 1 2 3 4 5 6 7 SIM card Antenna DIP switch RS232 Rx/Tx System Power 0 1 2 3 4 5 6 7...
Page 5
RTU-COM UCR-4XX/10XX UCR-8DIO 400134 A 100/28.05...
Page 6
The RTU is mounted on a 35mm DIN-rail (EN50022). For mounting and de-mounting- see the drawings below. CODE SWITCH/ADDRESS SELECTOR The code switch of the RTU-COM selects the station address, baud rate, etc. Code switch 1 2 3 4 5 6 7 8 9 1 0...
Page 7
RTU-COM Wiring Diagram - general Wire size Terminal blocks for I/O and power supply are Earth and power supply: max. 2,5mm (earth plug-in connectors with screw terminals. It is wiring must be 2,5mm and kept as short as recommended to use ferrules on wires.
Page 8
RTU-COM Wiring Diagram UCR-8DIO RS232 communication port (RS232 type only) DIP switch for DC supply addressing/setup Config port RS232 SIM card holder (only GSM) Mains supply External FME antenna connector supply for GSM (only GSM) 10 - 30V DC 0 1 2 3 4 5 6 7...
Page 9
RTU-COM Power Supply Battery/Solar panel Only type 40. Version 1x Version 00, 30 and 50 Please note that the power connector on top of the module is for Solar panel ONLY. Battery or bench supply connection to these terminals may damage the module.
Page 10
RTU-COM Digital Input / S0 counter Wiring Analogue Input (voltage or current) To activate the inputs an external voltage is 2 analogue inputs. Are configured from the fac- required, use e.g. the 12V supply from the tory according to the last digit in the type no: RTU.
Page 11
RJ11 connector below 10dB. Signal IO Interface Note: RTU-COM must NOT be power up Name Type without antenna. Powering up without antenna Not used. No connection needed or with wrong antenna (like single band type) Not used.
Page 12
Application ground wiring An protective ground back plane is recom- mended in the panel. The GND terminal on the RTU-COM and the DIN rail must be con- nected direct to the grounded back plane 0 1 2 3 SIM card...
Page 13
RTU-COM Configuration of the RTU-COM The RTU is configured with a PC running the configuration program. Connect a PC with a serial cable to the RTU programmer port (ca- ble UCC-301). 0 1 2 3 SIM card Antenna DIP switch...
Page 14
RTU-COM Waste and disposal notice This Electronic device falls under DIRECTIVE 2002/96/EC OF THE EUROPEAN PARLIAMENT AND OF THE COUNCIL of 27 January 2003 on waste electrical and electronic equipment (WEEE) 40134A 100/28.05...