2.11.7
Power Supply Voltage Changes
The following procedure is given so that the user can
configure the Power Supply voltage to suit a particular
incoming line voltage.
CAUTION: Only trained technical staff should be
allowed to reconfigure the terminal
Power Supply.
A chart is given in Figure 2-5 that describes the
various wiring configurations for the voltages 100 vac-
50/60 hz, 115 vac 50/60 hz, and 220 vac 50/60 hz.
Some of the changes are complex as when converting
from 115 vac 60 hz to any other voltage and
frequency. Figure 2-5 contains wiring diagrams
that explain these changes and the necessary
additional parts (if any) are listed to the right.
QUANTITY/ITEM
PART NO.
USE
1
Line Filter
610-0004-6617
llSvac BOI^z. lOOvac
50/60hz, & 230vac 50/60hz.
1
Line Cord
601-0602-2105
Used in 230vac S0/60hz
1
Circuit Breaker
611-0104-0150
Used in 230vac S0/60hz
S .250 Faston Terminals
704-0169-9778
Ail Cases
1 Connector (closed end)
606-0035-EC56
lOOvac 60/60hz only
2
No. 6 Lock Nut
701-0002-0006
All except llSvac 60Hz
2
Starlock Washers
701-0006-0006
All except 11 Svac 60IHz
TBl
WIRE
100 VOLT 50/60HZ
1
T1-Brown
2
Tl-Yellow
3
Fan
4
Line Filter No. 4
S
Key
6
T1-Black
7
Tl-Gray
8
Line Filter No. 5
9
Key
10
Blank
T1 Red
Fan t
115 VOLT 50Hz
1
Tl-Brown
2
Tl-Yoliow
3
Fan
4
Line Fiiter-No. 4
5
Key
6
T1-Grange
7
T1-Red
8
Fan
9
Line Filter No. 5
10
Key
230 VOLTS 50/60HZ
1
Tl-Brown
2
Fan
3
Line Filter No. 4
4
Key
5
Tl-Yellow
6
Tl-Red
7
Fan
8
Key
9
T1-Orange
10
Line Filter No. 5
Figure 2-5 Power Supply Voltage Change Documentation
(continued on following page)
FROM
TO
Tl-Vioiet
P2-9
Tl-Vioiet/White
P2-7
T1-Vioiet
P2-8
Tl-Green
P2-6
Tl-Groen
P2-5
Tl-Biue
P2-3
Tl-Blue
P2-2
SPK-Yeiiow
P2-1
SPK-Brown
P2-4
S1-2
CBI-1
Power Cord Bik. or Brn
CBI-2
Power Cord Green
Line Filter No. 2
S1-1
Line Filter No. 1
Power Cord Wht.or Blu
Line Filter No. 3
TBl
WIRE
TO
FROM
116\
fOLT 60Hz
Tl-Violet
P2-9
T1-Violet/White
P2-7
1
Tl-Brown
Tl-Violet
P2-8
2
Tl-Yellow
Tl-Green
P2-6
3
Fan
Tl-Green
P2-B
4
Switch S1-1
T1-Blue
P2-3
5
Key
Tl-Blue
P2-2
6
T1-Orange
SPK-Yeiiow
P2-1
7
Tl-Red
SPK-Brown
P2-4
8
Fan
S1-2
CBI-1
9
Power Cord-White
Power Cord Black
CBI-2
10
Key
Power Cord Green
El
*
t For 100 vac configuration connect T1 Red
and Fan lead togethiar using a closed end
connector. See parts list above.