  • Page 1 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...
  • Page 2 Manual 07500590 Model 3000-12 Model 3000-12 32 SPDT Switch Module 90400570 peration Manual Page 1 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 3 Giga-tronics will, at its option, repair or replace products that are proven defective during the warranty period. This warranty DOES NOT cover damage resulting from improper use, nor workmanship other than Giga-tronics service.
  • Page 4 San Ramon, California 94583 U.S.A. Type of Equipment: Model Series Number Switching Module 3000-12 Declaration of Conformity on file. Contact Giga-tronics at the following; Giga-tronics, Incorporated 4650 Norris Canyon Road San Ramon, California 94583 Telephone: 800.726.4442 (only within the United States) 925.328.4650...
  • Page 5 Manual 07500590 Model 3000-12 Record of Changes to This Manual Use the table below to maintain a permanent record of changes to this document. Corrected replacement pages are issued as Technical Publication Change Instructions (TPCI). When you are issued a TPCI, do the following: 1.
  • Page 6 Manual 07500590 Model 3000-12 Revision History Revision Description of Change Chg Order # Approved By Initial Release Reformatted 2/12 peration Manual Page 5 Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com...
  • Page 7: Table Of Contents

    Manual 07500590 Model 3000-12 Contents Contents ................................ 6 Chapter 1 Introduction ..........................7 1.1 Safety and Manual Conventions ......................7 1.1.1 Product Reference ........................7 1.1.2 Personal Safety Alert ........................7 1.1.3 Equipment Safety Alert ....................... 7 1.1.4 Notes ............................7 1.1.5 Electrical Safety Precautions .......................
  • Page 8: Chapter 1 Introduction

    Manual 07500590 Model 3000-12 Chapter 1 Introduction 1.1 Safety and Manual Conventions This manual contains conventions regarding safety and equipment usage as described below. 1.1.1 Product Reference Throughout this manual, the term “Common Core Switching Platform, Series 8800” refers to all models of within the series, unless otherwise specified.
  • Page 9: Chapter 3 Functional Description

    Model 3000-12 Chapter 3 Functional Description 3.1 Introduction This User Guide provides a basic description of the Model 3000-12, thirty two DPDT relays module. Also included are installation and input connection procedures, programming information, service and maintenance information. 3.2 General Description This module contains 32 DPDT Relays (Double Pole Double Throw Relays).
  • Page 10: Chapter 4 Block Diagram

    Manual 07500590 Model 3000-12 Chapter 4 Block Diagram CH 1A - NC CH 1A CH 1A - NO CH 1B - NC CH 1B CH 1B - NO CH 32A - NC CH 32A CH 32A - NO CH 32B - NC...
  • Page 11: Chapter 5 Controls And Indicators

    The following items are inside the module and can be reached by removing the side cover. 6.1 FUSE The ASCOR VXI 3000-12 uses a 10 Amp fuse in the +5 Volt line and is located on the Mother Board (MB) assembly. 6.2 VXI INTERRUPT LEVEL SELECTION The VXIbus interrupt level is set with three bits in the “3Eh”...
  • Page 12: Chapter 7 Specifications

    Manual 07500590 Model 3000-12 Chapter 7 Specifications Electrical Specification Number of relays Max Voltage: 120 VAC, 150 VDC Max Current: 2 amp Bandwidth: >30MHz (into 50 ohms to Analog Ground) Max Power 60 watts Path resistance: </=200 milliohm Connector: ITT Cannon 2DD100S Qty.
  • Page 13: Chapter 8 Register Map

    The Model 3000-12 is a VXI register based module. The switch paths are controlled via VXIMAX™ which is the 16/32 bit data controller. The Model 3000-12 can be programmed in 16 bit or 32 bit wide data. Through your VXI controller, write the data to the appropriate register as shown on the register map for the relay or relays in the register that is being closed.
  • Page 14 Manual 07500590 Model 3000-12 Register Description REGISTER: 8000h MODE: 16/32 bit FUNCTION: Relays K1-16 CONNECTION-A CONNECTION-B RELAY NC: J1-3, NO: J1-1, C: J1-2 NC: J1-29, NO: J1-27, C: J1-28 NC: J1-54, NO: J1-52, C: J1-53 NC: J1-79, NO: J1-77, C: J1-78...
  • Page 15 Manual 07500590 Model 3000-12 For example: To close relay K15 is to set the register to: Register 8000h Register Map, 16 Bit DESCRIPTION: 32 DPDT RRELAYSX, MOTHER BOARD PCB NUMBER: 85003240 ADDRESS 8000h OFFSET: ADDRESS 8002h OFFSET: Register Map, 32 Bit...
  • Page 16 Artisan Technology Group is your source for quality new and certified-used/pre-owned equipment SERVICE CENTER REPAIRS WE BUY USED EQUIPMENT • FAST SHIPPING AND DELIVERY Experienced engineers and technicians on staff Sell your excess, underutilized, and idle used equipment at our full-service, in-house repair center We also offer credit for buy-backs and trade-ins •...

Table of Contents