Opiz OP-D7D4A User Manual page 2

Audio door station

Advertisement

Ⅰ.VIEW
.
1.Front view
2
Rear view
+ MIC-
V+ G
1
2
B2
B1
Introductions for lines
V+
power line ,Connects with power +
1
Talking line from indoor phone.to outdoor unit. Connects with indoor phone
2
Talking line from outdoor unit to indoor phone.. Connects with indoor phone
3
Public line from outdoor unit to indoor phone.. Connects with indoor phone
4
Unlock line from indoor phone to outdoor unit ,Connect with indoor phone
LOCK Connect with E-lock
Ⅱ.OPERATION
When the outdoor unit is under standby status ,the visitor call the household by corresponding
names on the panel ,the system will call the corresponding indoor unit .When the indoor phone
ring ,the outdoor will ring same time , The household can pick up the phone and talk with the
visitor ,If let the visitor in , The householder can unlock the door by pressing "Unlock" button ,
Hang off the phone after the call . The system will back to standby status
Ⅲ.FUNCTIONS
1. Two way communication
2. Unlock
3. Power indictor
4. Maximum connect with 3 households
Ⅴ. DIAGRAM
1
2
3
4
B
spk
V+
G N D
1
2
3
4
+ LOCK-
3
4
+ LOCK-
S
M
L
① Call button
② Name plate
③ Mic
④ Speaker
⑤ Call line
GND
power line ,Connects with power --
Ⅳ. SPECIFICATIONS
Working voltage:
DC12
Standby current:7mA
Relative humidity:45%-95%
Temperature:-30℃-70℃
Dimension(mm):185*120*40
Install dimension:166*110*30mm
+
-
12V
K+
G N D
P o w er s upply
L+
L -
1
2
3
4
B1
B2
OP-D7B2A
Ⅰ.VIEW
1.Front view
Ⅱ.FUNCTIONS
1. Two way intercom
2. Unlock
Ⅲ.OPERATION
1.Talking : Intercom by picking up the receiver if hear the ring
2.Unlock: Unlock the e-lock by pressing unlock button when under talking status
Ⅳ.PERFORMANCE AND PARAMETERS
Working voltage:power from outdoor unit
Working curren:50mA
Standby current:30mA
Relative humidity:45%-95%
Temperature:-40℃-70℃
Atmospheric pressure:86-108Kpa
Fire endurance rating:IP33
Dimension:225*85*70mm
Net weight::440g
Ⅴ. SYSTEM CONNECTING LINE INTRODUCTIONS
1.If the main line is less than 50 meters , cross area should more than or equals 0.3mm
2.If the main line is from50-100 meters , cross area should more than or equals 0.5mm
3.If the branch line is less than 20 meters , cross area should more than or equals 0.15mm
4.If the branch line is less than 20-50 meters , cross area should more than or equals 0.3m
5.The line from power supply to outdoor unit and from outdoor unit to E-lock , cross area should
more than or equals 0.5mm .and the distance should be less than 15 meters ,otherwise need
increase the cross area
-1-
.
2
Rear view
B
1 2 3 4
B
① Unlock button
② Receiver
③ System connecting ,
connecting with outdoor unit
-2-

Advertisement

loading

This manual is also suitable for:

Op-d7b2a