Interface Signals; Connector Con2 For Manipulator (17 Pins); Connector Con3 For Manipulator (11 Pins) - YASKAWA MOTOWELD-T300D Instructions Manual

Ac/dc tig welder used exclusively for motoman
Table of Contents

Advertisement

9 Interface Signals

9.1

Connector CON2 for Manipulator (17 Pins)

Pin No.
No.
Corresponding to
Connector
1
P-R
Welding current
(CON2)
detection signal
output
2
S-T
Pulse
(CON2)
synchronization
signal output
3
K-L
Welding start/stop
(CON2)
command
4
A-B
Pulse current
(CON2)
reference
5
C-B
Base current
(CON2)
reference
∗ R indicates the manipulator side while W indicates the welder side.
Note: Connector model is as follows:
・Welder side : MS3102A20-29S (made by Japan Aviation Electronics Industry, Ltd.)
・Manipulator side : MS3106B20-29P (made by Japan Aviation Electronics Industry, Ltd.)
9.2

Connector CON3 for Manipulator (11 Pins)

Pin No.
No.
Corresponding to
Connector
1
J-K
(CON3)
2
E-F
(CON3)
3
G-H
(CON3)
4
A-B (negative side)
(CON3)
∗ R indicates the manipulator side while W indicates the welder side.
Note: Connector model is as follows:
Welder side: MS3102A24-20S (made by Japan Aviation Electronics Industry, Ltd.)
Manipulator side: MS3106B24-20P (made by Japan Aviation Electronics Industry, Ltd.)
Meaning
Detects that the welder current flows.
Detects the pulse current period at pulse
welding.
Commands welding start/stop.
Pulse current setting bias
Base current setting bias
Meaning
Wire feeding speed
Wire feeding speed setting bias
reference
Wire forward
Commands weld wire forward
feeding signal
feeding/stop.
Wire reverse
Commands weld wire reverse
feeding signal
feeding/stop.
Welding voltage
Outputs welding voltage.
output signal
Rectifies and outputs at AC.
Function
Direction*
W→R
W→R
R→W
R→W
R→W
Function
33
Signal Form
Photocoupler output
(Current detection at ON)
Photocoupler output
(Pulse period at ON)
Contact input (Start at
closed)
Analog voltage of 0 to 10
V
Analog voltage of 0 to 10
V
Direction*
Signal Form
R→W
Analog voltage of 0 to 14
V
R→W
Contact input (Forward
feeding at closed)
R→W
Contact input (Reverse
feeding at closed)
W→R
Analog voltage of 0 to
10 V (Insulate from other
circuits.)

Hide quick links: