Chapter 1 Introduction 1.1 Description FE1/V.35 interface converter is designed based on an ASIC chip. The chip adopts special patent technology of reduced dithering, digital phase locked and distill clock, E1 anti-jamming, etc. The inner software and hardware are all modularity, integrating coding, decoding, message insertion and alarm, and make the circuit simple so as to improve the reliability of the device.
Page 4
Dithering characteristic: comply with ITU-T G.823 standard Dithering tolerance: comply with ITU-T G.823 standard Impedance: 75Ω unbalanced/ 120Ω balanced Internal clock (default) Clock mode External clock Line clock Voltage: AC110V/AC 240V/DC –48V/DC –48V/DC Power +24V supply Power consumption: ≤5W Working temperature: 0°C~50°C Environment Storage temperature: -40°C~+70°C Relative humidity: 5%~95 %...
Chapter 2 Operation 2.1 Front Panel Fig 1. Front panel of FE1/V.35 Interface Converter 2.1.1 Indicators There are seven indicators in the front panel of FE1/V.35 interface converter, from right to left: Indicator of power supply Green Bright when power is on...
External clock and the connected DTE device doses not supply clock, E1LOS still bright when E1 looping. 2.2 Back Panel Fig 2. Back panel of FE1/V.35 Interface Converter (AC) Fig 3. Back panel of FE1/ V.35 Interface Converter (DC) 2.2.1 Power Supply AC socket: AC 220V input.
Fig 5. Sketch map of DC-48V connection NOTE: Please check the power polarity carefully, and connect after everything is confirmed. Otherwise the equipment may be caused the forever damages and we won’t take any responsibility because of this! 2.2.2 E1 Interface E1 75 /120 switch...
Page 8
Transmit clock B(from DCE) Receive clock A(from DCE) Receive clock B(from DCE) Table4. V.35 Interface Signal Assignments Connect FE1/V.35 Interface Converter with DTE device by the equipped DB25M/M34F cable. NOTE: Connect with DCE device by intercross cable, facture of intercross cable...
Table 5. Facture of V.35 intercross cable 2.2.4 Time Slots Settings Time slot settings switch for FE1/V.35 Interface Converter is located at the bottom of the device. On the bottom board of FE1/ V.35 Interface Converter, there is a quadrate slot. Under the slot, there are four 8-bit Dips (totally 32 bits) for setting E1 time slots.
Page 10
TS9 is available TS9 is invalid TS10 is available TS10 is invalid TS11 is available TS11 is invalid TS12 is available TS12 is invalid TS13 is available TS13 is invalid TS14 is available TS14 is invalid TS15 is available TS15 is invalid TS16 is available TS16 is invalid TS17 is available...
FE1/V.35 Interface Converter set as External clock. Phase setting(SW-3) Bit 3 of SW in rear panel is used to set V.35 data phase. FE1/V.35 Interface Converter can auto detect the phase of receiving data. The phase of transmittal data can be set by this switch. Defied as below:...
Page 12
Definition Specification Default sample when rising SW-3 Phase setting of transmittal V.35 data OFF: sample when falling Table 9. Phase setting of transmittal V.35 data LOOP Setting (SW-4, SW-5, SW-6) BIT4, BIT5, BIT6 of SW (SW-4, SW-5, SW-6) are LOOP Setting, REM only can used in framed E1, defined as below: DEFINITION SPECIFICATION...
Page 13
SW-6: Loop the remote device, use only in framed E1. shown as Fig 10: Fig 10. Loop the remote device PATT (SW-7) BIT7 of SW is PATT test, cooperate with loop settings to check up the device and line. The result can get by observing PTOK: LOCAL (Internal clock) REMOTE (Line clock) LOCAL...
Page 14
Follow(SW-8) BIT8 of SW is used to set follow or unfollow the opposite device time slot settings. Only used in LINE clock and the opposite device INTERNAL clock: Definition Specification Default ON: unfollow SW-8 Follow OFF: follow Table 12. Settings of follow NOTE: This function is available between the same type products (include Card type) of our company.
Check the power collocation of FE1/V.35 interface converter, if it is DC model, please pay attention to the voltage value and polarity, then connect the power supply referring to this manual.
Page 16
device may be caused permanent damages. The device has already adjusted optimal status before leaving factory, please don’t take apart the device privately if non technicians of our company. When the device has failure, you can make sure the failure range through self-loop function with the device, and contract with technical service center of our company in time.
Chapter 4 Troubleshooting Normal working status: when FE1/V.35 interface converter works normally, PWR (Green) indicator is bright, TXD (Yellow)、 RXD (Yellow) indicators are blinking, the others are off. When the device has failure, firstly make sure the failure range according to the status of the indicators, then deal with the problem.
Page 18
Please pay attention to the clock association when FE1/V.35 interface converter connect to DCE device via crossover cable, if DCE device is set to internal clock, then FE1/V.35 interface converter should be set to external clock; if DCE device is set to external clock, then FE1/V.35 interface converter should be set to internal clock.