WARRANTY AMERICAN WELDQUIP MIG guns and parts are warranted to be free of defects in material and/or workmanship for the period of time listed below. For any product found to be defective under normal use, AMERICAN WELDQUIP, INC. at our option, will repair, replace or issue a credit for the value of the defective product.
SAFETY PRECAUTIONS – READ BEFORE USING Before installing, operating or performing maintenance please read the safety precautions below. Failure to observe safety precautions can result in injury or death. CALIFORNIA PROPOSITION 65 WARNINGS This product, when used for welding and cutting, can produce fumes or gases which contain chemicals known to cause birth defects and cancer.
Page 5
ELECTRIC SHOCK CAN KILL WARNING - ELECTRICAL SHOCK CAN KILL. DO NOT TOUCH LIVE ELECTRICAL PARTS AND/OR USE IN DAMP LOCATIONS. The electrode and work (ground) circuit is electrically “HOT” whenever the welding equipment is on. Do not touch these electrically live parts with your bare skin or wet/damp clothing. Wear dry, hole-free gloves. Incorrectly installed or improperly grounded equipment is a hazard.
Page 6
WELDING AND CUTTING CAN CAUSE FIRE OR EXPLOSION WARNING – Welding and cutting produces sparks that fly off from the arc and can cause fires and/or explosions. Welding or cutting on closed containers, such as tanks, drums or pipes can cause them to blow up. Sparks can fly off from the welding or cutting arc.
INTRODUCTION PAPR Respiratory System is a combined face and breathing protection device for increased safety and comfort during welding. Please read these instructions carefully before unpacking. For proper use, see User Instructions or contact manufacturers for help. WARNING AND LIMITATIONS FOR USE Before each use, inspect the Respiratory System for damage and verify it operates properly.
UNPACKING AND ASSEMBLY The package must include: 1. The air fed welding + welding hood 2. The respiratory protection system (turbo unit + filter + waist belt) 3. Lithium-ion battery (2) 4. The tube, its anti-fire cloth and both end fittings 5.
INSTALLING THE BATTERY/CHARGING Slide the battery towards the back of the Make sure that the battery is locked in filtration unit. position. The battery can be charged on the filtration unit or separately. The battery is partially charged when delivered. It must be charged at a 100% (4 bars) before the first use. It is recommended to charge the batteries at a 100% before each use.
INSTALLING THE POWER UNIT TO THE BELT Remove the belt’s release buckle. Remove the fastening belt from the waist connector’s 2 belt loops. Make the fastening belt pass through the Position the Velcro® between the 2 loops. respiratory system’s 2 belt loops. Put the fastening belt back through the 2 belt Flip the filtration system and attach the loops.
BEFORE USE/FITTING AIRFLOW TEST Connect the breathing tube to the turbo unit and twist it clockwise to lock it. Insert the flowmeter at the tip of the tube. Press the ON button and maintain the tube in a vertical The air flow is sufficient if the marble reaches the position at eyes’...
OPERATION PAPR POWERED AIR RESPIRATOR There is a LCD display screen on BREATH-CLEAN Power unit to show the status of the unit. Part 1 shows the data of current air flow. Part 2 shows the level of the airflow. Part 3 shows the filter condition. Part 4 shows the battery.
Page 13
SCREEN ICON EXPLANATION Battery status Welding Grinding Shade range 5-9 Shade range 9-13 indication indication Sensitivity indication: Delay indication: Shade reading Memory selection 1 (low) to 5(high) 1 (short 0.1s) to 5 (long 0.9s) Note: Buttons on the left of the screen need to be pressed twice to start any settings. Otherwise they will not operate.
Page 14
appear on the screen. Then press SHADE button (23) repeatedly until the desired Shade shown in Icon 8. Note: -Choose an optimum Shade number for the required welding process or application (see Table 1). -If this ADF does not darken when striking arc, stop welding immediately and contact our representative. SENSITIVITY CONTROL The responsive to different light levels in various welding processes can be adjusted in the range 1-5(from low to high).
GRIND SELECTION ➢ Press WELD/GRIND button (26) repeatedly until icon 3 appears on the screen and the red light beside the button flashes. Additionally, icon 8 will show shade 4. Note:Do not weld in the Grind mode, the ADF will not darken. MEMORY SETTING 3 most frequently used setting can be stored and reactivated easily by using the 3 MEMORY buttons (27) on the right side of the screen.
PAPR WARNING SOUNDS The Powered unit will continuously monitor its functions for any faults. If any faults are found the unit will notify the user by beeping sounds. The number and length of the beeps indicate the type of fault. 1 Short Beep –...
Belt Size 35-2/5 x 51-2/5 in. (900mm to 1300mm) ADF AUTO DARKENING LENS 1. ADF Cartridge size 114 x 133 x 9.5 mm (4-1/2" x 5-1/4" x 3/8") 2. LCD Viewing area 100 x 83.4 mm 3. Light State Shade DIN 3 4.
TROUBLESHOOTING PROBLEM PROBABLE CAUSE ACTION 1.Motor is stuck Check and remove physical failure and restart the system. Return to dealer if LCD Fault code «E01» 2.Motor is damaged still shows E01 blinks 3.Blower structure failure caused by outer force 4.Circuit failure Fault code «E02»...