6. S
PECIFICATION
Output Power
Input Voltage range/ Frequency
Output Voltage Range (AC mode)
Output Voltage and Frequency (Battery mode)
Transfer Time
Battery Voltage
Charging Current
Output Waveform (Battery mode)
Operation Temperature
Operation Humidity
Unit dimension
Net weight
7.TROUBLESHOOTING
Problem
Possible Causes
1. Line cord plug is loose.
Inverter is not starting when connected
2. Breaker is broken.
to the mains voltage supply
3. Wall socket is damaged.
Output voltage is present,
inverter emits continuous beep sound,
Inverter is overloaded
the yellow LED flashes every 0.5 seconds
Inverter emits beep sound, battery
Low battery
capacity indicator flickers
1.Excessive loads connected.
Inverter does not provide expected
2.Battery is weak and cannot
backup time
provide enough energy.
1.The CPU inside inverter
Button on front panel does not work
is not running correctly.
2.Button is damaged.
1. Battery polarity is wrong.
2. Battery is overcharged.
Inverter cannot turn on the battery mode
3. Battery is discharged.
4. Inverter fault.
600VA/500W, 800VA/600W,
950VA/800W, 1200VA/1000W
145 ÷ 270VAC ± 5VAC (UPS mode)
100 ÷ 290VAC ± 5VAC (Inverter mode)/ 45 ÷ 65Hz
203VAC ÷ 238VAC ± 5VAC (UPS mode)
150VAC ÷ 255VAC ± 5VAC (Inverter mode)
220 ± 5VAC, 50Hz ± 0.5Hz
max. 10ms
12VDC or 24VDC
10A/20A (selecetable)
Sine Wave
0 ÷ 40°C
20 ÷ 90%
290 x 257 x 123mm
10.8kg
Action to take
1. Check the line cord plug.
2. Replace the breaker.
.
3. Check wall socket with a lamp
Turn off inverter and unplug excessive loads.
1. Charge batteries.
2. Replace batteries.
3. Call the service.
Do not draw any current from the inverter. Leave the
the device plugged in to the mains voltage for 10
hours. Then test it again. If inverter still can not provide
expected backup time, battery should be replaced.
Unplug line cord and battery terminals from the
inverter to let it shut down automatically. Then, plug in
line cord and battery again. If the button still fails,
please call the service.
1. Check battery and connections.
2. Check battery voltage using a voltmeter.
3. Connect the inverter to mains voltage and charge
the battery.
4. Call the service.
4
PURE SINE WAVE INVERTER UPS
CO-SinusUPS-600W-LCD
MODEL:
CO-sinusUPS-500W/xxx-LCD
CO-sinusUPS-600W/xxx-LCD
CO-sinusUPS-800W/xxx-LCD
CO-sinusUPS-1000W/xxx-LCD
xxx = 12V,24V
A
:
PPLICATIONS
Central heating and hot water systems,
Off-grid solar systems, home electronics, WI-FI,
yachts, campers etc.
U
SER
Please read and save this manual!
This manual is an important instruction that you should follow during
installation and maintenance of the inverter. Please read all instructions
before using the equipment and save this document for future reference.
CO-sinusUPS-600W-LCD-manual-R3, 20.03.10
M
ANUAL
1