Teach In Across-Corner Operation (Optional); Complete Setup By Carrying Out An Automatic Reference Run; Programming Changes; Initiating A New Reference Run - Hafele Free flap E Manual

Table of Contents

Advertisement

Available languages
  • EN

Available languages

  • ENGLISH, page 42
5. Programming
changes
» For step by step instructions, see picture section on page 153, point 4.2.
» Continue to next menu item or complete setup, see section "4.4 Complete
setup by carrying out an automatic reference run".
NOTE
The reference run must not be stopped or interrupted by intervening under any
circumstances.

4.3 Teach in across-corner operation (optional)

NOTE
In order to avoid front panel collisions with an across-corner configuration, the
respective menu items of both drive units must be called up within 30 seconds.
» For step by step instructions, see picture section on page 154, point 4.3.
» Complete setup by carrying out a reference run, see section "4.4 Complete
setup by carrying out an automatic reference run".

4.4 Complete setup by carrying out an automatic reference run

» Close front panel and trigger a reference run by applying gentle pressure to the
front panel. The settings are saved by carrying out two complete opening and
closing procedures.
NOTE
The reference run must not be stopped or interrupted by intervening under any
circumstances.

5.1 Initiating a new reference run

A new reference run may be required if changes are made to the system (e.g. new
front panel with a different weight) or if the drive stops during the opening or closing
run.
» Select menu item and close the cabinet flap within 30 seconds.
» Trigger a reference run by applying gentle pressure to the front panel.
» For step by step instructions, see picture section on page 155, point 5.1.
NOTE
The reference run must not be stopped or interrupted by intervening under any
circumstances.
NOTE
If several drive units are being used in order to create a continuous front panel,
the new reference run must be carried out or activated simultaneously at all drives
connected in parallel.

5.2 Factory settings

The drive unit is reset in the as-delivered condition.
NOTE
All saved settings are deleted.
» For step by step instructions, see picture section on page 156, point 5.2.

5.3 Push button sender reset

The push button sender is reset to the factory settings and can be taught in again.
» Remove battery from housing of push button sender and insert again with the
button pressed.
» For step by step instructions, see picture section on page 157, point 5.3.