Safety Sign:
When using the optical power meter, always take bask safety precautions to reduce the harm for
the testers, and injury to persons. All the safety sign may not mark in this manual.
Warning : Prohibited misconduct and operation, to prevent any improper conduct and
operation of the damage.
Notice: notic the important information, notification, and referencs, thse notice
information should be understand.
Safety sign on the instrument:
WEEE Sign : Users of electrical and electronic equipment from private households
.
should have the possibility of returning WEEE at least free of charge
Safety Advice
1.When the tester use Disposable alkaline batteries, do not charge it.
Ensure the correct
polarity installation,when replace the battery.
2. When the products are not in use, please remove the batteries and kept separate to avoid
instrument damage caused by battery leakage. If leakage occurred, Please do not touch.
3.
To prevent electric shock, do not open the product case, only the authorized qualified
professionals can do the maintenance; Do not expose the testers to rain or wet conditions, to
avoid the risk of fire or electric shock
4. Instruments used LCD screen. Do not fall the instrument. If the LCD are seriously hit, it may
cause fluid leakage. And please do not touch.

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the DT-OLS-116 and is the answer not in the manual?

Questions and answers

Summary of Contents for DAYTAI DT-OLS-116

  • Page 1 Optical Light Source (DT-OLS-116) Safety Sign: When using the optical power meter, always take bask safety precautions to reduce the harm for the testers, and injury to persons. All the safety sign may not mark in this manual. Warning : Prohibited misconduct and operation, to prevent any improper conduct and operation of the damage.
  • Page 2: Table Of Contents

    Optical Light Source (DT-OLS-116) Contents Chapter 1 Standard Configuration------------------------------------------------------------------------- 1 Chapter 2 Overview-------------------------------------------------------------------------------------------- 1 Features----------------------------------------------------------------------------------------------------- 1 Chapter 3 Specifications------------------------------------------------------------------------------------2 Chapter 4 Function------------------------------------------------------------------------------------------ 3 4.1Front----------------------------------------------------------------------------------------------------- 3 4.2 Left Side------------------------------------------------------------------------------------------------ 4 4.3 Top-------------------------------------------------------------------------------------------------------5 4.4 Backside------------------------------------------------------------------------------------------------ 6 Chapter 5 Operation Instruction---------------------------------------------------------------------- 6 5.1 Ways of power supply------------------------------------------------------------------------------- 6 5.2 Power on the laser source-------------------------------------------------------------------------- 8...
  • Page 3: Chapter 1 Standard Configuration

    Optical Light Source (DT-OLS-116) Chapter 1 Standard Configuration Name Optical Light Source User Manual 1.5V AA battery Power Supply Unit Cotton Swabs Carry Bag Chapter 2 Overview This handheld optical light source is a new released tester in 2010, designed for the fiber optical network installation, acceptance, and maintenance.
  • Page 4 Optical Light Source (DT-OLS-116) Laser type FP-LD(others specify on requests) Maximum Output Power(dBm) -5(can be adjustable, others specify) Adjustable step size(dBm) <0.5 (adjustable between -5~-12dBm) Stability(dB,15min,20℃) ±0.1 Stability(dB,30min,20℃) ±0.05 Modulation(Hz) CW, 270,330,1K,2K Fiber Port FC/PC or FC,SC,ST interchangeable 3*AA,1.5V Alkaline Battery...
  • Page 5: Chapter 4 Function

    Optical Light Source (DT-OLS-116) Chapter 4 Function 4.1Front (10) Power Key ON/OFF the instrument Power Saving setting: the unit will automatically shut off after 10 minutes idle time, Once choose this setting, the “auto-off” will display on the left bottom of the screen. This power saving is the default setting, once open the power meter, will enter into this mode.
  • Page 6: Left Side

    Optical Light Source (DT-OLS-116) Rated power: Rated output power Down the rated power Down the rated output power Modulation adjustment/wavelength identifying Laser on. After on the tester, firstly press , to laser on the light source. Short press shift the frequency.
  • Page 7: Top

    Optical Light Source (DT-OLS-116) Connect the AC adaptor with the port 4.3 Top (1) Dust cap In order to protect the optical connector, avoid damage on the connector, so when not in use make sure that you place the dust cap over the connectors.
  • Page 8: Backside

    Optical Light Source (DT-OLS-116) 4.4 Backside (1)Label Content include the function, and the instrument information (2) bracket Collapsible metal bracket, 0~90 degree can adjusted. (3)Battery Pack Can insert 3 1.5AA batteries. Notice: When insert the batteries, take a note of their positive(+)and negative(-) connector orientation, The negative battery connector should be against the spring.
  • Page 9 Optical Light Source (DT-OLS-116) Battery Power indicate There are 5 Grades for the battery power indication: left 70%~100% electricity left 40%~70% electricity left 30%~40% electricity left 20%~30% electricity。 not enough electricity, left less than 20%,the power meter will be forced power off.
  • Page 10: Power On The Laser Source

    Optical Light Source (DT-OLS-116) AC power supply sign When use the AC adaptor, connect the power plug as pic, and insert to the AC socket. AC adaptor Power Supply Power Plug Notice:Please use only the power supply unit supplied with the tester, use other kind of PSU may cause damage for the instruments.
  • Page 11: Backlight Setting

    Optical Light Source (DT-OLS-116) When the tester is standby, press key can cancel or choos auto-off function.If auto-off fucniton are choosed, the “Auto-off” will display on the left bottom of the screen. 5.3 Backlight Setting After open the optical power meter, long press , choose backlight control mode.
  • Page 12 Optical Light Source (DT-OLS-116) laser source. Normally less than 15 minutes would be okay. 5.4.1 Open the dust cap, connect with the patch cord. Notice: Make sure the connector and the end-face of the patch cord is clean, and take notice on the type of the patch cord, make sure the correct patch cord are connected.
  • Page 13 Optical Light Source (DT-OLS-116) Output wavelength 5-10 5.4.4 Output power Every selected wavelength can adjust the output power within the range (-5 ~ -12dBm), and also can load with the output frequency. Press to down the output power, while to load the output frequency, (5-11~5-13)
  • Page 14: Wavelength Automatic Identification

    Optical Light Source (DT-OLS-116) 5.5 Wavelength Automatic Identification  Connect The light source with its same serials power meter THE MATCHED OPTICAL POWER METER. Enable light source be Under “Wave ID” operation mode: press of light source to laser on ...
  • Page 15: Power Off

    Optical Light Source (DT-OLS-116) 270Hz 270Hz 330Hz 330Hz 1KHz 1KHz 2KHz 2KHz The light source THE MATCHED POWER METER 5-15 Note:Frequency ID and wave ID cannot be operated at the same time. To avoid risk of serious eye damage, please do not look into the optical port of laser source at any time.
  • Page 16: Chapter 8 Quality Warranty

    Optical Light Source (DT-OLS-116) 7.5 Keep regular cleanings on optical port of power meter, please clean with cotton swabs supplied using alcohol properly. Chapter 8 Quality Warranty Details of warranty terms and conditions are given as below: 1) The company. warrants that the light source will be free from defects in material and workmanship for a period of 18 months.

Table of Contents