  • Page 1 PX300 CT Sensor User manual...
  • Page 2: Table Of Contents

    6 Sensor configuration.................8 7 Connection scheme.................11 8 Dimensions....................12 9 Technical data..................13 Manufacturer reserves the right to make modifications in order to improve device operation. PXM Marek Żupnik sp.k. Podłęże 654 tel. +48 12 385 83 06 32-003 Podłęże mail: info@pxm.pl Rev.1-2 BDO register number 000005972 www.pxm.pl...
  • Page 3: Description

    Safety conditions PX300 is a device powered with safe voltage 24V DC; however, during its installation and use the following rules must be strictly observed: 1. The device may only be connected to 24V DC with current-carrying capacity compatible with technical data.
  • Page 4: Connectors And Control Elements

    5. All repairs and connections of outputs or DMX signal can only be made with cut off power supply. 6. All sudden shocks, particularly dropping, should be avoided. 7. The device should be installed in a place ensuring adequate lighting conditions and at the same time providing protection against obstructing the light source.
  • Page 5: Starting The Device

    Description of connectors and their application : Name Description RX2+ MASTER mode: RS-485 input – receiving measurements from PX300 operating in SLAVE mode RX2- TX2+ unused TX2- power supply +24V RX1+ unused RX1- In MASTER mode: DMX-512 output TX1+ In SLAVE mode: RS-485 output for data transmission to the...
  • Page 6: Master / Slave Function

    Value negation above MASTER / SLAVE function The PX300 has been equipped with the MASTER / SLAVE function. In MASTER mode, the device works as transmitting DMX signal to receivers, e.g. to LED lamps. The DIP switch is responsible for enabling the MASTER function.
  • Page 7 SLAVE mode allows to connect two sensors with each other. In this mode, a second sensor must be connected, connected to the main one, averaging the measurements and sending the calculated value to external devices. The following figure shows the DIP switch set in the SLAVE mode. 1 2 3 4 5 6 The following figure shows the connection of two devices in MASTER / SLAVE mode :...
  • Page 8: Sensor Configuration

    Sensor configuration If it is necessary to change the parameters of the sensor settings, it is possible. PXM has prepared software for communication between the PX300 and a PC with Windows . This software is supplied with the device on a CD ®...
  • Page 9 The Upgrade, Config Read, Config Write and Run options are available after connecting to the PX300 with the Connect function: Upgrade → performs a firmware upgrade (same as after selecting Yes • in the Connect option) Config Read → enables loading the configuration from the EPROM •...
  • Page 10 Save Config → save the currently displayed configuration to the • indicated file Load Config → read the configuration from the selected file and • display it in the Configuration panel Exit → exits the program • Defaults → loading and displaying the default settings in the panel •...
  • Page 11: Connection Scheme

    Connection scheme V- V+ RX2+ RX2– TX2+ 24V DC TX2– power supply +24V RX1+ RX1– TX1+ TX1– +24V output LED lamps e.g. PX392...
  • Page 12: Dimensions

    Dimensions 105 mm RX2+ RX2– TX2+ TX2– +24V RX1+ RX1– TX1+ TX1– +24V...
  • Page 13: Technical Data

    Technical data type PX300 power supply 24V DC power consumption 25mA 2500 – 6000K operating range of the sensor 0 – 10000 lux output connectors terminal blocks supported protocols DMX, RS-485 degree of protection IP65 housing material polycarbonate weight 0.15kg...
  • Page 14 Podłęże, 19.09.2019 DECLARATION OF CONFORMITY PXM Marek Żupnik spółka komandytowa Podłęże 654, 32-003 Podłęże we declare that our product: Product name: CT Sensor Product code: PX300 meets the requirements of the following standards, as well as harmonised standards: PN-EN IEC 63000:2019-01...