DFRobot IV-18 Operation Instruction Manual

Vfd tube clock, energy pillar

Advertisement

Quick Links

IV-18(ИВ-18)VFD Tube Clock
Energy Pillar
Operation Instruction
v1.2.0
Contents
Attention....................................................................................................................................................... 2
Functional features...................................................................................................................................... 2
Technical specifications............................................................................................................................... 2
Package content........................................................................................................................................... 3
Appearance layout....................................................................................................................................... 3
IR remote control introduction.................................................................................................................. 3
Warning tone introduction......................................................................................................................... 4
Display mode switch................................................................................................................................... 4
Power on/off................................................................................................................................................ 4
Adjust brightness........................................................................................................................................ 4
Temperature unit ℃/℉.............................................................................................................................. 5
Set time......................................................................................................................................................... 5
Set date......................................................................................................................................................... 5
Set alarm....................................................................................................................................................... 5
Menu 1: Date format YY-MM-DD/YY-DD-MM/DD-MM-YY/MM-DD-YY........................................... 6
Menu 2: Time format 12H/24H................................................................................................................. 6
Menu 3: Set UTC.......................................................................................................................................... 6
Menu 4: GPS Status..................................................................................................................................... 7
Menu 5: Set GPS BAUD RATE..................................................................................................................... 7
Menu 6: Set leader 0 mode........................................................................................................................ 7
Menu 7: Set Buzzer mode.......................................................................................................................... 8
Menu 8: Date interval of scrolling display............................................................................................... 8
Menu 9: Temp interval of scrolling display.............................................................................................. 8
Menu 10: Set auto power off Time........................................................................................................... 9
Menu 11: Set auto power on Time........................................................................................................... 9
Timer function............................................................................................................................................. 10
Special function ......................................................................................................................................... 10
Announcements ........................................................................................................................................ 10

Advertisement

Table of Contents
loading

Summary of Contents for DFRobot IV-18

  • Page 1: Table Of Contents

    IV-18(ИВ-18)VFD Tube Clock Energy Pillar Operation Instruction v1.2.0 Contents Attention……..………….…………………………………………………………………………………………………………….…… 2 Functional features….…………………………………………………………………………….…………………………………… 2 Technical specifications………………………………………………………………………………………...……………….…… 2 Package content………………………………………………………………………………………...….…………………………… 3 Appearance layout………………………………………………………………………………..……….…………………………… 3 IR remote control introduction……………………………………………..…………………….……………………………… 3 Warning tone introduction….…………………………………..………………………...….…………………………………… 4 Display mode switch……………………………………………………..…………………………………………………………… 4 Power on/off…………………………………………………………….……………………..………………………………………… 4 Adjust brightness………………………………………………………………………….…………………………………………… 4 Temperature unit ℃/℉……………………………………………………………….……………………..………………………...
  • Page 2: Attention

    Exposing outdoor prohibited, using in moist or raining place prohibited. ◇ Warning: Do not let the children touch the clock without adult. Functional features Eight digits IV-18 (ИВ-18) VFD tubes display. (1980-1090 made in USSR). Display hour, minute and second (12 or 24 hours format optional). Display year, month...
  • Page 3: Package Content

    IV-18(ИВ-18)VFD Tube Clock Instructions Http://www.nixieclock.org Package content Name Quantity Name Quantity VFD tube clock Mini USB power line IR remote controller 1 User manual Appearance layout ③ ④ ① ② 4 Name Name IV-18 VFD tube IR receiver GPS Receiver Socket...
  • Page 4: Warning Tone Introduction

    IV-18(ИВ-18)VFD Tube Clock Instructions Http://www.nixieclock.org Warning tone introduction Beep Description Meaning 1 shot beep Normal operation Be… 1 long beep Confirm and saved Bebebe 3 shot beep Sync with satellite time successfully Bebebebe 4 shot beep Set error/cancel/alarm Display mode switch Display time Mode After power on the clock, or press POWER button in shutdown state, it’s display time...
  • Page 5: Temperature Unit

    IV-18(ИВ-18)VFD Tube Clock Instructions Http://www.nixieclock.org Temperature unit ℃/℉ In the display temperature mode, press FUNC button can switch temperature unit repeatedly. ■ This option stored in the clock and can’t lose when power off. Set time In display time mode, press SET button enter set time mode.
  • Page 6: Menu 1: Date Format Yy-Mm-Dd/Yy-Dd-Mm/Dd-Mm-Yy/Mm-Dd-Yy

    IV-18(ИВ-18)VFD Tube Clock Instructions Http://www.nixieclock.org Press CANCEL abort setting and exit. ■ After setting success, clock will beep for a long time, and return display time mode. ■ If setting is illogical, clock will beep four times with short time, and abort save setting then return display time mode.
  • Page 7: Menu 4: Gps Status

    IV-18(ИВ-18)VFD Tube Clock Instructions Http://www.nixieclock.org Press OK to save the settings and exit the menu, when you power on or cut off the power it will remember what you set before. ■ This setting stored in the clock and can’t lose when power off.
  • Page 8: Menu 7: Set Buzzer Mode

    IV-18(ИВ-18)VFD Tube Clock Instructions Http://www.nixieclock.org Press OK to save the settings and exit the menu 6, or you can cancel it. ■ This setting stored in the clock and can’t lose when power off. ■ The display mode only effective for displaying time, when you set the time, the leader 0 will always display.
  • Page 9: Menu 10: Set Auto Power Off Time

    IV-18(ИВ-18)VFD Tube Clock Instructions Http://www.nixieclock.org ■ If the time interval was beyond 0, the clock will displayed temp for 3 seconds per N seconds. Menu 10: Set auto power off Time Press FUNC key to enter in menu, use RIGHT/LEFT key to change the number, and then enter in menu 10 set auto power off time.
  • Page 10: Timer Function

    IV-18(ИВ-18)VFD Tube Clock Instructions Http://www.nixieclock.org Timer Function Under Display time mode, press ALARM key 3 times can enter in timer function. When you enter in timer function, clock will adjust countdown time in acquiescent condition for 1 hour. When the first character was ‘o’ in the left side, it was stopped. Then you can use the digital number to set the countdown time, it could be 00:00:01-99:59:59, that is 1 second to 99 hours 59 minutes and 59 seconds.

Table of Contents