Sanitising air dryer

Advertisement

INSTALLATION,
WARNING
The appliance is only intended to be installed or maintained by qualified
personnel.
• The appliance is not intended for use by young children or infirmed persons
without supervision. Young children should be supervised to ensure that
they do not play with the appliance.
• Means for all pole (Live & Neutral) disconnection (air-gap of at least 3mm)
must be included for fixing wiring. The disconnection device must be
installed in accordance with the wiring rules.
For appliances fitted with a supply cord and plug - if the supply cord is
damaged, it must be replaced by the manufacturer, its service agent or
similarly qualified persons.
INSTALLATION
Always ensure:
The appliance is mounted clear of swinging doors or any other feature likely to cause
damage.
The mounting surface is even to avoid distortion of the base plate.
The front of the appliance is able to swing down through 90° to allow disassembly.
Housing may get damaged and require being support by one hand during changing of
accessories.
Avoid placing the machine over a pedestal or bench top as this may trigger the sensor
unnecessarily.
For bench top installation, it is recommended that the appliance be
mounted at least 300mm above bench tops.
TO INSTALL
1.
Place the back plate against the wall and with the aid of a spirit level (Bubble
Level)
2.
Mark out the 5 mounting holes on the bottom of the back plate -
3.
Determine the electrical connection method.
a)
b)
c)
4.
Secure the back plate to the wall using 5 x 12 gauge wood screws, 6mm
masonry bolts or similar.
5.
Ensure the appliance is connected to an electrical circuit with adequate
capacity and the necessary safety features (i.e. RCD), as per local
regulations.
6.
THE APPLIANCE MUST BE CORRECTLY EARTHED.
7.
Fit the case to the back plate by holding the case at 90º and then sliding the
case across and connect the internal power cable to the defeat switch
cover. Ensure that the cable is correctly routed to prevent damage to the
internals of the machine.
8.
Rotate the case to the vertical, and apply moderate pressure on the front of
the case to compress the back plate seal, while operating the key lock to
secure the appliance.
MAINTENANCE AND WARRANTY INSTRUCTIONS
For fixed wiring installation, ensure the cord passes through the
supplied grommet in the top right hand corner of the back plate.
For wiring to the nearest power point, break the appropriate tab
(left or right) from the bottom of the rubber seal and install the
power cord.
Hand Dryers which have a power cord (not fitted), measure the
length between the dryer and the power outlet and cut to
remove excess cord before fitting.
MODEL: R & S
After Sales, Service and Warranty support e-mail: info.nz@paciichygiene.com
Recommended
installation height
from floor to
underside
MEN:
1240 mm
WOMEN: 1100 mm
DISABLED:
900 mm
Drawing 1: S Back Plate
Drawing 2: R Back Plate
Drawing 3 : Mains Power