Download Print this page

Gaobiao F500 User Manual

Smart thermostat

Advertisement

Quick Links

F500 Smart Thermostat User Manual
Introduction
F500 thermostat is used to control up to 2
stages heating and 2 stages cooling system with
8 types control system, EM heat activation,
adjustable compressor delay time and O/B
changeover. It is with tempered touch sensitive
screen, quick connecting terminals to save
installer's time. 7days programmable and four
modes everyday make users' life convenient
and comfortable.

Advertisement

loading
Need help?

Need help?

Do you have a question about the F500 and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Gaobiao F500

  • Page 1 F500 Smart Thermostat User Manual Introduction F500 thermostat is used to control up to 2 stages heating and 2 stages cooling system with 8 types control system, EM heat activation, adjustable compressor delay time and O/B changeover. It is with tempered touch sensitive screen, quick connecting terminals to save installer’s time.
  • Page 2 NO.1 Package In the package, there includes: 1. 2sets screws and anchors; 2. one thermostat; 3. Quick install guide;...
  • Page 3 NO.1 Technical Parameters Power supply: AC24V Temp. Setting range: 10~32℃ Self-consumption: <2W Wire connection: Terminals Resistive load: <1A Outcase: Tempered glass + PC Thermister: NTC Thermister Dimension: 102*102*20mm Install: 60 or 82mm Wifi network: 2.4GHz NO.2 Features l Application range: gas/fuel boiler, electric heating, water heating, heat pump etc. 8 types control systems.
  • Page 4 NO.3 Wires Connection Instruction CAUTION: ELECTRICAL HAZARD Can cause electrical shock or equipment damage. Disconnect power before beginning installation. CAUTION: EQUIPMENT DAMAGE HAZARD Compressor protection is bypassed during testing. To prevent equipment damage, avoid cycling the compressor quickly. CAUTION: MERCURY NOTICE If this product is replacing a control that contains mercury in a sealed tube, do not place the old control in the trash.
  • Page 5 NO.3 Wires Connection Instruction Terminal Conventional Heat Pump Description Common 24V AC power Heating or changeover 2nd stage heating or Auxiliary heating Compressor Stage 1 Compressor Stage 2...
  • Page 6 NO.4 Display...
  • Page 7 NO.5 Functions & Settings Modes: The thermostat had five modes: EM HEAT, HEAT, OFF, AUTO, COOL. * Note: EM HEAT can be activated in FACTORY SET. Fan modes: The fan can be set to AUTO mode or ON mode. During AUTO mode, the fan will run based on the working condition of the compressor. If the comperessor is on to heat or cool, the fan will be ON.
  • Page 8 NO.5 Functions & Settings Change fan mode: Press the options under Fan bar to switch between AUTO and ON. Set Date& Time Press Menu, then the screen displays DATE TIME, then press Edit, then the screen displays SETUP YEAR first, press + or - to set the current year, then press Next to switch to SETUP MONTH, press + or - to set the current month, press Next to switch to SETUP DATE, press + or - to set the current date, then press Next to SETUP HOUR, press + or - to set the current hour, then press Next to SETUP MINUTE, press + or - to set the current minute.
  • Page 9: Set Working Mode

    NO.5 Functions & Settings Set WORKING MODE Press Menu, then the screen displays DATE TIME, then press Next once, then the screen displays SETUP WORKING MODE, then press Edit, the screen displays SCHEDULE, press UP or DOWN arrow to switch between SCHEDULE and HOLD modes.
  • Page 10 NO.5 Functions & Settings Set WIFI Press Menu, then the screen displays DATE TIME, then press Next twice, then the screen displays SETUP WIFI, then press Edit, the screen displays SMART MODE, press UP or DOWN arrow to switch between SMART MODE and AP MODE.
  • Page 11 NO.5 Functions & Settings Fig. 1 Fig.2 Fig.3 Fig.4...
  • Page 12 NO.5 Functions & Settings Set SCHEDUL SET Press Menu, then the screen displays DATE TIME, then press Next 3times, then the screen displays SCHEDUL SET, then press Edit, the Monday will be blinking, press + or - to choose the week day you want to schedule, then press Next to switch to the first time period 6:00 will be blinking.
  • Page 13: User Setup

    NO.5 Functions & Settings USER SETUP Press Menu, then the screen displays DATE TIME, then press Next 4times, then the screen displays USER SETUP, then press Edit to enter into user setup interface.
  • Page 14 NO.5 Functions & Settings 1. USER SETUP: Press Edit to set the relative settings under User Setup. 2. TEMP SCALE: Press + or - to switch between ℃ and ℉ . 3. TEMP ADJ: Press + or - to adjust. This is used to calibrate the indoor temperature. Range: -3℃ to 3℃ 4.
  • Page 15: Factory Set

    NO.5 Functions & Settings FACTORY SET Press Menu, then the screen displays DATE TIME, then press Next 5times, then the screen displays FACTORY SET, then press Edit to enter into user setup interface.
  • Page 16 NO.5 Functions & Settings 1. FACTORY SET: Factory set includes system type, compressor protect, emergency heat mode and change over. 2. SYSTEM TYPE: The thermostat supports up to 8 types(from 00 to 07) of heating and cooling combined system. 3. COMP PROTECT: Time delay to start the compressor. Range: 00~10minutes. 4.
  • Page 17: Set Reset

    NO.5 Functions & Settings Set CLEAN SCREEN Press Menu, then the screen displays DATE TIME, then press Next 6 times, then the screen displays CLEAN SCREEN, then press Done, then the user will have 30seconds to clean the screen without changing any setting. Set RESET Press Menu, then the screen displays DATE TIME, then press Next 7 times, then the screen displays RESET, then press + or - to change between ON and OF, then press Done.
  • Page 18 NO.5 Functions & Settings...