INSTALLATION INSTRUCTIONS CB-3012 SERIES CABINET LOCK

I. Order Information

Item
Contents
CB-3012S\LD 12VDC or 24VDC
CB-3012S\L
12VDC or 24VDC
CB-3012F\LD 12VDC or 24VDC
CB-3012F\L
12VDC or 24VDC

II. Specifications

Power input
Current
Door Status Sensor (DSS)
Lock Status Sensor (LSS)

III. Contents

Strike x1
Lock body x1
V.
Changing lock mode of operation (Fail Secure to Fail Safe)
(Power to open)
Fail-Secure

I. Wiring diagram

.Fail-Secure (Power to open) mode
Black
(Power OFF)
Yellow
(Lock +)
LSS
Red
Blue
Green
White
Orange
DSS

Wiring diagram A: Fail-Secure (Power to open)

CB-3012 Ver.01-100930
LED
Lock Status Sensor Door Status Sensor
12VDC
0.28A
Max.3W; Max.30VDC;Max.0.2A COM., NO.
Max.30VDC;Max1A
Twin adhesive x1
Cover Plate x1
Screws x6
Magnet x1
(Only DSS)
Opened the housing.
LED/ Emitted Color
Power on
Green
Without (X)
Power off
V-
V+
(LED)
NO.
NC.
COM.
NC.
NC.
NO.
COM.
NO.
RELAY
×
×
24VDC
Stable PSU recommended
0.14A
Changeable by power input and higher outer temp.
COM., NO., NC.

V. Power input setting

Turned the chassis upside down.
(Power OFF)
LSS
Orange
DSS

Wiring diagram B: Fail-Secure (Power to open)

- 1 -
Lock mode (Default)
Fail-Secure (Power to open)
Fail-Secure (Power to open)
Fail-Safe (Power to lock)
Fail-Safe (Power to lock)
A. 12VDC input setting :
.Jumper setting as
shown on below-
PIN-1 and PIN-2 closed
PIN-3 and PIN-4 closed
B. 24VDC input setting :
.Jumper setting as
shown on below-
PIN-3 and PIN-4 closed
(Power to lock)
LED/ Emitted Color
Power on
Green
Power off
Red
V-
V+
Black
(LED)
Yellow
(Lock +)
Red
NO.
Blue
NC.
Green
COM.
NC.
White
NC.
NO.
NO.
Patent No. M 384227
RoHS
1 2 3 4
1 2 3 4
Fail-Safe
COM.
RELAY

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the CB-3012 Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Suntrust CB-3012 Series

  • Page 1 INSTALLATION INSTRUCTIONS CB-3012 SERIES CABINET LOCK RoHS I. Order Information Item Contents Lock Status Sensor Door Status Sensor Lock mode (Default) ○ ○ ○ CB-3012S\LD 12VDC or 24VDC Fail-Secure (Power to open) ○ ○ × CB-3012S\L 12VDC or 24VDC Fail-Secure (Power to open) ○...
  • Page 2 .Fail-Safe (Power to lock) mode LED/ Emitted Color LED/ Emitted Color Power on Green Power on Green Without (X) Power off Power off Black Black (Power ON) (Power ON) (Lock +) (Lock +) (LED) (LED) Yellow Yellow Blue Blue Green Green COM.

This manual is also suitable for:

Cb-3012s/ldCb-3012s/lCb-3012f/ldCb-3012f/l

Table of Contents