SAFETY PRECAUTIONS

• Assembly, commissioning and servicing may only be performed by specialist personnel! Applicable European and national
regulations for erection of electric systems must be complied with.
• Connect the device only to the power supply voltage indicated in the technical data and on the nameplate.
• Do not open up the casing!
• In case of assembly or maintenance work, the device must be disconnected from all currents!
• Operate the device only under the conditions defined in the operating instructions!

TECHNICAL DATA

Power supply:
Power Consumption:
Ambient temperature:
Casing:
Mounting:
Terminals:
Relay outlets:
Note
Contacts are not protected against overload, provide for external protective devices!
Signalling:
Delay:
Measurement circuit:
Note
The device may only be connected to overflow and leakage sensors of our lines MAXIMAT SU ..., MAXIMAT LW ... or MAXIMAT VK!
Measuring circuit cable length:
CE labels
In accordance with Low Voltage Guidelines (72/23/EEC), EMV Guidelines (89/336/EEC) and:
Over voltage category II, if higher transient over voltage than category II expected, then special measures must be taken.
Pollution degree 1 (clean environment)
DIBT certification
Certification N°: Z-65.11-122, Z-65.13-265, Z-65.13-294, Z-65.40-201, Z-65.40-316 and Z-65.40-272 for overflow and leakage
sensors under Art 19 of the Water Management Act (WHG§19)
Note:
Observe the General Construction Regulatory Certification of the connected overflow or leakage sensor!
555 M1 06 B
230 V ±10%; 50/60 Hz or 24 V DC ±10%
Note: Device may only be connected to the power supply via an electric cut-off device
approx. 3 VA / 3 W
-20 ... +60°C
22.5 x 75 x 110 mm, IP40
Quick mounting for standard rails DIN EN 50 022 (top hat rail 35 x 7.5 mm)
IP20, screw connectors, line cross section max 2.5 mm
2 ea. change over contacts, potential free
Switching voltage max 250 V 50/60 Hz
max 115 V DC
max 3 A AC, 0.5 A DC
Minimum load 10 mA at 5 V DC
LED (green) Operating
LED (green) Relay engaged
LED (red) Filler alarm
LED (red) Meas. circuit break
LED (red) Meas. circuit short
0.3 to 3 sec OFF-delay with adjustable pots
Right stop = max delay
Left stop = min delay
(With SHR CS the pot is located behind the removable front panel)
Max voltage 12 V DC
Max power (short circuit) 110 mA
Max conduction inductivity < 5 mH
Max conduction capacity < 0.5 μF
Max 300 m
Min cross-section 0.5 mm
- EN 50 082-2:1995
- EN 55 011 (Class A):1998
- EN 61010-1:1993