Technical Information Manual Revision n. 4 18 June 2008 MOD. A3000NF 3-PHASE NOTCH FILTER MANUAL REV. 4 NPO: 00120/04:3000N.MUTx/04...
Page 2
This product must be installed by qualified personnel; the 3-phase EMC filter Mod. CAEN A3000NF does not support operation in hostile areas (magnetic field). CAEN reserves the right to change partially or entirely the contents of this Manual at any time and without giving any notice. Disposal of the Product The product must never be dumped in the Municipal Waste.
(magnetic field). Technical description The CAEN Mod. A3000NF is a two channel notch filter which must be used with the A3486 3-Phase 220/400 Vac – 48 Vdc converter. I/O connectors are housed on the module rear panel.
WARNING: ALTHOUGH THE CHASSIS IS ALREADY INTERNALLY CONNECTED TO PROTECTION EARTH PROVIDED BY MAINS POWER SUPPLY PLUG, CAEN STRONGLY ADVICES TO CONNECT THIS TERMINAL TO A GOOD EARTH WITH A LOW IMPEDANCE CABLE PATH, IN ORDER TO IMPROVE EMI SHIELDING AND SAFETY.
The A3000NF is provided with front panel fixing holes for 19" rack-mounting and will occupy 3U of rack space. Rear support should be provided when fitted in a 19" rack. The A3000NF is a heavy unit (32kg) and should be regarded as a two-man lift. Take suitable precautions when lifting.
Document type: Title: Revision date: Revision: User's Manual (MUT) A3000NF 3Phase Notch Filter for A3486 18/06/2008 EXTERNAL OR INTERNAL OPERATING ENERGY SOURCE. THIS DISCONNECTING MEANS SHALL DISCONNECT ALL CURRENT CARRYING CONDUCTORS. WARNING: DO NOT TOP LOAD WARNING: IN ORDER TO PREVENT RISK OF ELECTRIC SHOCK OR FIRE HAZARD DUE TO OVERHEATING, ENSURE THAT THE UNIT’S VENTILATION...
2.2.3 Rack mounting The Mod. A3000NF is an equipment for BUILDING-IN: it must be installed in a 19” equipment rack and operated with its upper grid unloaded. Use the front panel rack-mount brackets to install the unit in the rack.
2.2.4 AC source The Mod. A3000NF ACsource is as follows: The input voltage range and current required is specified in § 1.4. Ensure that under heavy load, the AC voltage supplied to the unit does not fall below the specifications described in §...
WARNING: INTERNAL FANS ARE POWERED ONLY BY THE LEFT TRIPHASE INPUT, THEREFORE FOR COOLING PURPOSES, IT IS IMPORTANT THAT, WHENEVER ONLY ONE CHANNEL OF THE A3000NF IS USED, THAT HAS TO BE THE LEFTMOST (FROM REAR PANEL VIEW, SEE § 1.3).