  • Page 1 UniTracer [Electronic locking device for container] USER MANUAL FOR UniTracer L-100 This guide explains the device UniTracer L-100. Version 1 September 2017 www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 2: Table Of Contents

    3.4 Device reset method ............................12 3.5 APN and NFC setting method ........................13 4. Trouble Shooting ................................20 4.1 Device debugging method ..........................20 4.3 Log data analysis method ..........................33 5. Device FAQ ................................... 35 www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 3: Precautions Concerning Pre-Service

    - To use an NFC card, you must register the NFC card ID in the L-100 device. - This device can be operated in at least one Member State of EU without infringing applicable requirements on the use of radio spectrum. 1.2 Device package configuration UniTracer L-100 Mini B type USB cable www.unisem.co.kr iot@unisem.co.kr...
  • Page 4 - UniTracer L-100 Specification Item Specifications Model UniTracer L-100 Temperature -30~+80℃ Humidity 0~99% Electrical Usage 3.78VDC 32Bit MPU Data Storage 1Mbit EEPROM x 2 792 Times(33 days) Data Transmission (24 Collections per day, every hour) Lithium-Ion Battery Capacity 6,000mAh(Rechargeable) Open/Close of door, Location,...
  • Page 5 1.3 Component parts of the device ①Lock Wire Cable ③ Right Wire Segment ④NFC Antenna ② Left Wire Segment ⑤Operation Switch ⑥USIM Port ⑦mini B type USB Port ⑧Reset Switch www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 6: Device Installation And Sealing Method

    - Attach the magnet on the back of the L-100 to the flat surface (steel material) of the container and tighten the device to the container. - When attaching the L-100 to a container, etc., be sure to install the L-100 in the following direction to obtain optimal GPS reception. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 7 Skyward GPS Antenna - GPS reception rate is the best when the GPS antenna is pointing in the sky. <Figure. Device installation Position> <Figure. actual device installation example> www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 8: How To Unseal And Retrieve The Device

    When the wire is disconnected, a green light blinks to receive the GPS(to send the device's open signal). When the green light is off, a blue light will come on for the data communication. The blue light turns off when data transmission is completed. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 9: How To Use The Device

    - At this time, the Operation switch flashes blue. - When the device is connected to the network and the data transmission is finished, the blue light turns off. 4) After the Operation switch light is blinking, the device waits until the next operation. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 10: Insertion Of The Usim

    Open the water-proof cover and insert it into the following directions. (Once engaged, ensure that the correct tightening is achieved and the correct orientation is achieved.) <Figure. Device USIM insertion direction> < Figure. Actual device USIM insertion example> www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 11: Check Battery Remaining Volume

    3) You can check the remaining battery level in the tracking monitoring system. You can check the remaining battery level in 'Battery' item in 'Transport history' - 'Tracking ' by accessing the tracking monitoring system. Here, the remaining battery level is displayed in %. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 12: Device Maintenance

    - Press the Operation switch on the device and press the Reset switch when no light flickers. (When the remaining battery power is normal) - When upgrading the firmware of the device, press the reset switch after completing the file transfer. ※ Refer to UniTracer L-100 Firmware upgrade manual. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 13: Apn And Nfc Setting Method

    5) After Serial COM port is recognized, COM port connects to ‘115200’ Speed. (Checking the COM port can be found in Device Manager on your PC.) 6) After the device closes, the device is working normally again. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 14 How to use the PuTTY Program Install the PuTTY progam to use the PuTTY. Download the program from http://www.chiark.greenend.org.uk/~sgtatham/putty/latest.html Download the MSI 64-bit file(putty-64bit-0.68-installer.msi). www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 15 +82.31.724.2548...
  • Page 16 +82.31.724.2548...
  • Page 17 The screen is shown like screen after run the PuTTY program. Select the ‘Serial’ (the Blue circle), set your PC COM port number in the Serial line. You can identify the COM port number in the Device Manager in your PC. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 18 $ set nfc [arg2] [arg3] 10 units of NFC can be registered per device. Each NFC ID can be registered as numerical number from 0 to 9. The ‘arg2’ is the index of the registered NFC ID. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 19 After entering the command, NFC card will be touched on the NFC antenna. $ save ex) When registering with NFC key value ‘4f3d1122’ at ‘3’ index $ set nfc 3 4f3d1122 $ save ex) Delete the NFC key value at ‘3’ index $ set nfc 3 0 $ save www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 20: Trouble Shooting

    II 2017/08/18 04:56:53 BSU(0:0:1) SM(0) BAT(4350) PN532Begin: PN532 Begin ..Ready for NFC SAMConfig: SAMConfig writeCommand: [PN532] PN532 Wakeup Power on NFC writeCommand: [PN532] Write: readAckFrame: [PN532] Ack: readAckFrame: OK readResponse: [PN532] Read: readResponse: length0 = 0x02, length1 = 0xFE www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 21 = V, 41 14.925740 N, 069 23.448850 E LogPrint: BAT = 4350 LogPrint: NFC = 0x6E 0xD7 0x7E 0xF1 LogPrint: EventCode = 0x01 LogPrint: DoorState = 0x00 LogPrint: rssi = 0x00 gpsBegin: Enable II 2017/08/18 04:56:56 BSU(0:0:1) SM(1) BAT(4266) www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 22 EepWriteForLog: Success LogEnqueue: addr = 0x00004720 Save the log with the GPS value EepWriteForLog: d0 = 0x47, d1 = 0x20, devAddr = 0x00A0 EepWriteForLog: Success Log save successful. GSM GSM_START: Start GSM operation GSM GSM_SendCMD: gsmSeq = 0 www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 23 GSM GSM_ProcessFin: <== GSM : OK GSM GSM_SendCMD: gsmSeq = 5 GSM GSM_SendCMD: SEND CMD [0] : AT+CGMR GSM GSM_ProcessFin: <== GSM : 08.90 GSM GSM_ProcessFin: <== GSM : OK GSM GSM_SendCMD: gsmSeq = 6 GSM GSM_SendCMD: SEND CMD [0] : AT+CGSN www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 24 GSM GSM_SendCMD: SEND CMD [0] : AT+CPIN? GSM GSM_ProcessFin: <== GSM : +CPIN: READY GSM GSM_ProcessFin: <== GSM : OK GSM GSM_SendCMD: gsmSeq = 10 GSM GSM_SendCMD: SEND CMD [0] : AT+UPSV? GSM GSM_ProcessFin: <== GSM : +UPSV: 0 www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 25 II 2017/08/18 04:57:09 BSU(0:0:1) SM(0) BAT(4327) II 2017/08/18 04:57:10 BSU(0:0:1) SM(0) BAT(4326) II 2017/08/18 04:57:11 BSU(0:0:1) SM(0) BAT(4328) GSM GSM_Process: Retry GSM GSM_SendCMD: gsmSeq = 14 GSM GSM_SendCMD: SEND CMD [0] : Retry(99) : AT+CREG? Attempt to Retry www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 26 GSM GSM_Process: Retry GSM GSM_SendCMD: gsmSeq = 14 GSM GSM_SendCMD: SEND CMD [0] : Retry(97) : AT+CREG? GSM GSM_ProcessFin: <== GSM : +CREG: 2,0 GSM ResATCREGq: CREGq D : +CREG: 2,0 GSM GSM_ProcessFin: <== GSM : OK www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 27 GSM GSM_ProcessFin: <== GSM : OK GSM GSM_SendCMD: gsmSeq = 17 GSM GSM_SendCMD: SEND CMD [0] : AT+CSQ Receiving sensitivity II 2017/08/18 04:57:21 BSU(0:0:1) SM(0) BAT(4350) GSM GSM_ProcessFin: <== GSM : +CSQ: 25,99 RSSI: 25 , Quality : 99 www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 28 GSM GSM_ProcessFin: <== GSM : +UPSND: 0,8,1 GSM GSM_ProcessFin: <== GSM : OK GSM GSM_SendCMD: gsmSeq = 24 GSM GSM_SendCMD: SEND CMD [0] : AT+USOCR=6 GSM GSM_ProcessFin: <== GSM : +USOCR: 0 GSM GSM_ProcessFin: <== GSM : OK GSM GSM_SendCMD: gsmSeq = 25 www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 29 GSM GSM_ProcessFin: <== GSM : OK LogPickUnsend: addr = 0x00004720 EepReadForLog: Success main: Send Log LogPrint: TIME = 17/08/18 04:56:59 LogPrint: GPS = A, 41 13.906110 N, 069 22.551380 E LogPrint: BAT = 4350 LogPrint: NFC = 0x00 0x00 0x00 0x00 www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 30 II 2017/08/18 04:57:27 BSU(0:0:1) SM(0) BAT(4350) II 2017/08/18 04:57:28 BSU(0:0:1) SM(0) BAT(4350) II 2017/08/18 04:57:29 BSU(0:0:1) SM(0) BAT(4350) II 2017/08/18 04:57:30 BSU(0:0:1) SM(0) BAT(4350) II 2017/08/18 05:02:57 BSU(0:0:1) SM(0) BAT(4350) II 2017/08/18 05:02:58 BSU(0:0:1) SM(0) BAT(4350) II 2017/08/18 05:02:59 BSU(0:0:1) SM(0) BAT(4350) www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 31 II 2017/08/18 05:03:08 BSU(0:0:1) SM(0) BAT(4335) gpsStateMachine: RTC : 17 08 18 05:03:08+00:00 gpsStateMachine: GPS : 17 08 18 05:03:07+00:00 gpsEnd: Disable LogEnqueue: addr = 0x00004740 EepWriteForLog: d0 = 0x47, d1 = 0x40, devAddr = 0x00A0 EepWriteForLog: Success GSM GSM_START: Start www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 32 GSM GSM_SendCMD: gsmSeq = 0 GSM GSM_SendCMD: SEND CMD [0] : AT GSM GSM_ProcessFin: <== GSM : AT GSM GSM_ProcessFin: <== GSM : OK GSM GSM_SendCMD: gsmSeq = 1 www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 33: Log Data Analysis Method

    Date is shown as Year/Month/Day Hour: Minute: Second Event code Open Close Shocking Broken Open status ‘0’ means open. ‘1’ mean close. GPS signal status ‘V’ means that transmission is successful. ‘A’ means that transmission is fail. Latitude & Longitude DD mm.mmmmm type www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 34 17/08/25 06:55:40, 1, 0, A, 37 24.088240 N, 127 06.467960 E, 4236, 0xD0 0x76 0x5 - Meaning: August 25 2017 6:55:40(Date), 1(event code), 0(open status), A(GPS reception status), 37 24.088240 N(latitude), 127 06.467960 E(longitude), 4236(battery value), D0-76-58-7E(NFC key value) www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 35: Device Faq

    NFC cards (ISO14443 Type A). Up to 10 NFC cards are available, and NFC card settings can be done by the procedure below. ① Connect your L-100 device to your PC using a mini B type USB cable. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 36 ② Enter Speed 115200 ③ Choose the ‘Serial’ among the Connection type and click ‘Open’ at the bottom ③ Enter the command to register the NFC card. $ set nfc 0 ( Register the NFC card at position 0) www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 37 ④ Press ENTER and then load the NFC card that you want to register on the NFC tag section of the device. ⑤ The card will be registered normally with a beep sound. - To check the information of the registered card, enter ‘show info’ in Emulator SW and press ENTER. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 38 NFC card. - After connecting a portable external battery (External battery for general mobile phone is also available) to the USB port of the L-100, you can unseal it with the NFC card. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 39 ④ When using SIM that does not support roaming service when traveling between countries. ⑤ When communication enters the shadow area and communication is not made temporarily. ※ Please contact your SIM provider except for ⑤ case. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 40 - The L-100 uses a Lithium-Ion battery with a capacity of 6,000 mAh. If the device is setting like as every 10 minutes of the GPS reception cycle and every one hour of the data transmission cycle, it can be used for approximately 33 days under normal running. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 41 13) How to shut down your device when you're finished the transportation? - When the transport is completed, if you open the wire of the equipment and unseal it, the device will automatically shut down after the last event signal transmission. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...
  • Page 42 Changes or modifications not expressly approved by the manufacturer (or party responsible) for compliance could void the user’s authority to operate the equipment Body effects This equipment should be installed and operated with greater than 20 cm between the radiator and your body. www.unisem.co.kr iot@unisem.co.kr +82.31.724.2548...