  • Page 2 Important Safety Instructions Please keep this manual for future reference. This manual contains all safety, installation and operating instructions for iCAN Mini - an integration of solar charge inverter and controller. Please carefully read all instructions and precautions in the manual before installation and usage. ...
  • Page 3: Table Of Contents

    Table Of Contents 1. General Information ........................3 1.1 Product overview and features ....................3 1.2 Basic system introduction ....................4 2. Installation Instructions ......................6 2.1 Installation precautions ......................6 2.2 Connecting wire specifications and circuit breaker model selection ........8 2.3 Installation and Connection ....................
  • Page 4: General Information

    1. General Information 1.1 Product overview and features The iCAN Mini series is a new hybrid charge control inverter device, which integrates solar energy, utility charge and AC output. It features high response speed, high reliability and high industrialization standard, etc., by adopting DSP design and advanced control algorithm. It provides four charge modes: Solar Only, Utility Priority, Solar Priority and Mixed charging.
  • Page 5: Basic System Introduction

    1.2 Basic system introduction iCAN Mini can be applied to a system typically including: 1. Solar panel: Converting light energy into DC power, charging the battery through the iCAN Mini. It can also be directly inverted into AC power to supply power to the load. 2.
  • Page 7: Installation Instructions

    ○ ○ CAN communication port ON / OFF ○ ○ USB communication port Fan air vent ○ ○ RS485 communication port LCD screen ○ ○ Stem node ports Buttons ○ ○ Instantaneous utility Inverter + MPPT charge fan overcurrent protection ○...
  • Page 8  After turning off the power switch, there is still high voltage inside the iCAN Mini. Please do not open or touch the internal devices. After the completion of capacitance discharge, related operations can be carried out.  Please do not install the iCAN Mini in harsh environments where is damp, greasy, inflammable and explosive, or dust is excessively accumulated.
  • Page 9: Connecting Wire Specifications And Circuit Breaker Model Selection

    Model No. diameter of PV array breaker model 10mm 2 /8AWG iCAN Mini 3500 2P—63A Note: The voltage connected in series must not exceed the maximum PV input open circuit voltage of 145V.  Please refer to the following table for the recommended AC input wire diameter and switch:...
  • Page 10 iCAN Mini and the battery is far, the thicker wire rod can reduce the voltage decline to improve the system performance. Note: The above wiring diameter and circuit breaker are only recommended. Please select the proper wiring diameter and circuit breaker according to actual situation.
  • Page 11: Installation And Connection

    2.3 Installation and Connection Installation steps: Step 1: Determine the installation location of iCAN Mini, such as the wall surface, as well as the heat radiation space. When installing the iCAN Mini, ensure that there is sufficient air flowing through the radiation fins of the iCAN Mini.
  • Page 12 Installation of AC output, AC output wire port and grounding. ① Take out the port and disassemble it as follows: ② Thread as follows: ③ Fix cables of different colors to the proper positions in the connector using allen driver: red – L; green –...
  • Page 13 Note: Image 3: finished proper connection Image 4: three positions with signs printed on the port. ④ Assemble t parts as follows, as per instructions shown. ⑤ Installation finished.
  • Page 14 WARNING ① The utility input and AC output are high voltage, please ensure the disconnector or protector is switched off before connecting. ② Be cautious of your own safety throughout the connection. DO NOT Switch on the disconnector or protector, ensure the positive and negative poles of all parts are connected properly. ③...
  • Page 15: Working Mode

    Switch OFF the circuit breaker at the battery end, then the rocker switch ON the right side of iCAN Mini. The "AC / INV" flashes to indicate that the inverter is working normally. Again, switch OFF the circuit breaker of PV array and utility power. After the AC is outputted normally, turn on AC load one by one, to avoid the protection action caused by a large momentary impact from the simultaneous startup of the load.
  • Page 16: Output Mode

     Mixed charging (Solar and utility): Charge is completed with hybrid supplement of solar power and utility power. Solar MPPT is primary source for charge of battery, and utility power is supplied when solar energy is not sufficient. When solar energy is sufficient, charge source is switched from utility power to solar energy.
  • Page 17 photovoltaic panel if the load power is less than the power supplied by solar energy, but the maximum inversion load shall be the half of rated power. When solar power is not available, utility power is switched for supplement. This mode is to maximize the usage of solar energy and maintain the battery capacity at the same time, and it is suitable for the place in which power grid is stable relatively.
  • Page 18: Instruction For Parameter Setting

    4. Instruction for parameter setting 4.1 Parameter viewing Press the “UP” and “DOWN” keys on the LCD screen to scroll through the page to view the machine parameters. Page Parameters on the left side Parameters Parameters on the right number of the screen middle of the screen side of the screen...
  • Page 19: Parameter Setting

    4.3 Parameter setting Operating instruction for keys: press ‘SET’ to enter or exit setup menu, then Parameter #00 will flash. Press ‘UP’, ‘DOWN’ and ‘ENT’ to edit the parameters when parameter is flashing, then press ‘ENT’ to confirm changes, finally press ‘ENT’ to exit. Parameter Parameter Setting...
  • Page 20 Parameter [01] = SOL/ SBU, Battery voltage of battery is lower than [04] 46.0V voltage to settings, output is switched from (default) line inverter to utility power. Setting range: 44V~52V Parameter [01] = SOL/ SBU, Battery voltage of battery is higher than [05] 56.0V voltage to settings, output is switched from...
  • Page 21 (default) voltage: 56.8V; Floating charge voltage: 55.2V Effective for lithium iron Default constant charging [08] LFP phosphate battery voltage: 56.8V; adjustable Effective for ternary Default constant charging [08] NCA lithium battery voltage: 56.8V; adjustable Battery Improve charge voltage improve [09] 57.6V Effective for user defined Stepped voltage: 0.4V charge...
  • Page 22 Battery Effective for opened lead- Equalizing the charge voltage. [17] 58.4V equalization acid, user-defined or Setting range: 48V~58.4V (default) voltage sealed lead-acid battery. Stepped voltage: 0.4V Battery Effective for opened lead- Equalizing the charge time. [18] 120 equalized acid or sealed lead-acid Setting range: 5min~900min (default) time...
  • Page 23 Alarm off when primary source Beeps while [26] DIS changed primary source is [26] ENA Alarm on when primary source interrupted (default) changed Disable automatic switching to [27] DIS Bypass utility power when over load output when [27] ENA Enable automatic switching to over load (default) utility power when over load...
  • Page 24: Parameters Of Different Types Of Battery

    4.4 Parameters of different types of battery Battery type Sealed Opened lithium iron Ternary lead- lead- User define lead-acid phosphate lithium Parameters acid acid (User) (FLD) (LFP) (NCM/NCA) (SLD) (GEL) Off voltage in over 36~60V voltage Equalized charge 58.4V 56.8V 59.2V 36~60V voltage...
  • Page 25: Rs485 Communication Function

    This port is also can be used to communicate with RS485 bluetooth communication module developed by POMCube, and inverter with controller can be connected with mobile phone’s bluetooth APP after matching with this module, operating parameters and state of inverter with controller can be checked with mobile phone’s bluetooth APP.
  • Page 26: Usb Communication Function

    5.4 USB communication function This port is USB communication port, which is used to complete USB communication with upper computer software stored on CD-ROM. “CH340T driver for USB to serial chip’ should be installed in computer for usage of this port”. 6.
  • Page 27: Fault Code Meaning

    Input undervoltage When utility voltage is lower than 100V, the utility charging will be stopped, but the protection of derated by-pass output can be achieved. Utility Overvoltage When the battery voltage reaches the voltage point of overvoltage disconnection, the protection for PV and utility will be automatically stopped charging the battery, preventing the battery battery from being damaged due to overcharge.
  • Page 28 Overvoltage protection 【09】 PvVoltHigh for PV Overcurrent software 【10】 PvBuck1OCSw protection for buck1 Overcurrent software 【11】 PvBuck2OCSw protection for buck2 【12】 bLineLoss Utility power failure Bypass overload 【13】 OverloadBypass protection Inverter overload 【14】 OverloadInverter protection Inverter overcurrent 【15】 AcOverCurrHw hardware protection 【16】...
  • Page 29: Partial Troubleshooting Measures

    6.3 Partial troubleshooting measures Fault Troubleshooting measures Check whether the air switch of battery or PV is closed; is the switch in No screen display "ON" state? Press any button on the screen to exit sleep mode. Charge battery overvoltage Measure the battery voltage, and see whether it exceeds 60V, and protection disconnect the air break switch of PV array and utility...
  • Page 30: System Maintenance

     POMCube assumes no responsibility for damages caused by: ① Improper use or damage due to improper use.
  • Page 31: Technical Parameters

    8. Technical parameters iCAN Mini 3500 Remark Continuous output power 3500VA/3500W at -10° C ~ 45° C If the sum household electrical Continuous appliances power is beyond the output power limit in a certain environment 3000VA/3000W temperature,inverter output will at 46° C~...
  • Page 32 Rated voltage Voltage range 40~60VDC Low voltage warning point Low voltage cut-off point Over-charge protection point Discharge maximum efficiency Rated voltage 120Vac Voltage range 90-140Vac Frequency 45Hz-65Hz AC input maximum current Maximum switching 20ms AC input time AC charger Operating 100-140Vac voltage range AC charger...
  • Page 33 charge current The maximum charge power equals to maximum charge Maximum current multiply by maximum 2880W charge power battery voltage charge. The actual charge power depends on PV energy and the battery voltage Thunder prevention Ensure that when the The battery is battery voltage is forbidden to higher than the PV...
  • Page 34 rate: working 10s then shutdown output and warning ③ load rate > 150%: working 5s then shutdown output and warning Standby work in inverter mode which AC power <20W output 120V is not connect to any consump household electrical appliances tion Thermal Intelligent adjustable speed fan...