Deutronic SmartCharger Series Operating Instructions Manual

Suitable for 12 v dc vehicle electrical networks/batteries

Advertisement

Quick Links

Deutronicstr. 5, D - 84166 Adlkofen, Germany
Tel.:
+49 (0) 8707 920-0
Fax:
+49 (0) 8707 1004
E-mail: sales@deutronic.com
http://www.deutronic.com
- Valid from device firmware version 02.00.013 -
Suitable for 12 V DC vehicle electrical networks / batteries
Important note
This device must only be used by qualified, specialist personnel for its specified application. Read
the operating instructions carefully and comply in all cases with the safety instructions and the
specifications of the battery manufacturer!
Depending on any customer-specific delivery specifications, the parameters described may differ
or some modes may not be available. If you have any questions regarding the parameterization
of your device, please contact Deutronic Elektronik GmbH or one of our worldwide service centers.
SmartCharger Operating Instructions / MPC6.1
SmartCharger Series
Operating Instructions
Illustration similar
Last updated: 02.07.2020
Page 1 of 16

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the SmartCharger Series and is the answer not in the manual?

Questions and answers

Summary of Contents for Deutronic SmartCharger Series

  • Page 1 Depending on any customer-specific delivery specifications, the parameters described may differ or some modes may not be available. If you have any questions regarding the parameterization of your device, please contact Deutronic Elektronik GmbH or one of our worldwide service centers. SmartCharger Operating Instructions / MPC6.1 Last updated: 02.07.2020...
  • Page 2: Table Of Contents

    Deutronicstr. 5, D - 84166 Adlkofen, Germany Tel.: +49 (0) 8707 920-0 Fax: +49 (0) 8707 1004 E-mail: sales@deutronic.com http://www.deutronic.com Contents Installation and Safety Instructions ..................3 Assembly ..........................3 2.1. Mains Connection ......................3 2.2. Charging cable ....................... 3 Control elements.........................
  • Page 3: Installation And Safety Instructions

    The installation and safety instructions, as well as the data sheets, can be found on our website at www.deutronic.com. Alternatively, please contact Deutronic Elektronik GmbH or one of our worldwide service centers 2. Assembly 2.1.
  • Page 4: Control Elements

    Deutronicstr. 5, D - 84166 Adlkofen, Germany Tel.: +49 (0) 8707 920-0 Fax: +49 (0) 8707 1004 E-mail: sales@deutronic.com http://www.deutronic.com 3. Control elements 3.1. Control panel The control elements, incl. LEDs and buttons, are shown below: Status LED (Color depends on operating mode)
  • Page 5: Signaling

    Note: Depending on any customer-specific delivery specifications, the parameters described may differ or some modes may not be available. If you have any questions regarding the parameterization of your device, please contact Deutronic Elektronik GmbH or one of our worldwide service centers. 3.3.1. Standby mode...
  • Page 6 Deutronicstr. 5, D - 84166 Adlkofen, Germany Tel.: +49 (0) 8707 920-0 Fax: +49 (0) 8707 1004 E-mail: sales@deutronic.com http://www.deutronic.com Operating mode: Charging Pb State Status LED LED 2 LED 3 LED 4 Load detection active Illuminated solid orange Flashing...
  • Page 7: Commissioning

    Deutronicstr. 5, D - 84166 Adlkofen, Germany Tel.: +49 (0) 8707 920-0 Fax: +49 (0) 8707 1004 E-mail: sales@deutronic.com http://www.deutronic.com Operating mode: EPS (external power supply / buffer mode) State Status LED LED 2 LED 3 LED 4 Load detection active...
  • Page 8: Preparing The Charging Cables For Use In Showrooms

    Tel.: +49 (0) 8707 920-0 Fax: +49 (0) 8707 1004 E-mail: sales@deutronic.com http://www.deutronic.com 4.1. Preparing the charging cables for use in showrooms To make it easier to position the device under the vehicle, the charging cables can be separated by means of the decoupler. (See Figure 2)
  • Page 9: Initial Setup

    Tel.: +49 (0) 8707 920-0 Fax: +49 (0) 8707 1004 E-mail: sales@deutronic.com http://www.deutronic.com 4.2. Initial setup Once the device has been connected to the mains supply, a chaser appears featuring the three colors of the status LED (red, green, blue) and the three LEDs which display the state of charge (green, yellow, yellow).
  • Page 10: Operating Modes

    If you have any questions regarding the parameterization of your device, please contact Deutronic Elektronik GmbH or one of our worldwide service centers. Cable compensation mode is used to measure or compensate the resistance value of the connected charging cables.
  • Page 11: Charging Pb / Chargingli/Lfp

    If you have any questions regarding parameterization, please contact Deutronic Elektronik GmbH or one of our worldwide service centers. In this operating mode, it is possible to charge either a battery which is installed in the vehicle or a "stand-alone"...
  • Page 12: Powerup

    If you have any questions regarding the parameterization of your device, please contact Deutronic Elektronik GmbH or one of our worldwide service centers. With lithium-iron phosphate batteries, the battery management system may open a relay to protect the battery in certain circumstances (e.g.
  • Page 13: Eps (External Power Supply)

    If you have any questions regarding the parameterization of your device, please contact Deutronic Elektronik GmbH or one of our worldwide service centers. Warning! Batteries may only be charged in "CHARGE XX" or "XX LTC” modes, as the parameters and monitoring functions required for ensuring safe battery charging are only activated in these programs.
  • Page 14: Error Messages

    Note: Depending on any customer-specific delivery specifications, the parameters described may differ or some modes may not be available. If you have any questions regarding the parameterization of your device, please contact Deutronic Elektronik GmbH or one of our worldwide service centers. Errors...
  • Page 15 Deutronicstr. 5, D - 84166 Adlkofen, Germany Tel.: +49 (0) 8707 920-0 Fax: +49 (0) 8707 1004 E-mail: sales@deutronic.com http://www.deutronic.com Status LED flashing red + The device detects overheating during In the event of significant heat development due to current state.
  • Page 16: Service Center / Repairs

    'Service Worldwide'. 8. Warranty Disclaimer The customer is responsible for the correct use of the device. Deutronic cannot assume any liabil- ity for damages of any kind caused by use of the device.

Table of Contents