Ares AR200N Series User Manual

Pure sine wave ups

Advertisement

Quick Links

User Manual
UPS
Pure Sine Wave
1-3KVA

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the AR200N Series and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ares AR200N Series

  • Page 1 User Manual Pure Sine Wave 1-3KVA...
  • Page 2: Table Of Contents

    CONTENTS 1. Safety And Summary 2. Working principle 3. Products features 4. Technical specification 5. Product components 6. Installation and usage 7. Maintenance 8. Packing List...
  • Page 3: Safety And Summary

    Warning! Equipment must be connected to the ground 1. Safety And Summary 1. The equipment must be connected to the ground. Make sure connect UPS Please obey the items below to ensure the security: to the ground well while connecting AC to supply power ●...
  • Page 4: Products Features

    2.3 Main power off: 2.5 Battery and charging: In main power off condition, batteries will supply power to the inverter promptly, 1.Automatic self-recharging occurs when UPS is connected to the main power. then the power can be sent to user's equipments uninterruptedly after though The charger can charge the batteries up to 90% within 8 hours.
  • Page 5 3.7 Automatically shut off when there is no load in inverter mode 3.4 Protective functions of online UPS: (option): ● Overload on main power condition: on main power condition, UPS will alarm for 60s if the load is over 110%, then it will turn to bypass mode, with ringing When UPS is in inverter mode, the alarm will disappear after 40 seconds, and disappeared either.
  • Page 6: Technical Specification

    Note: 4. Technical specification 1): Data after with“ (H)”means the ups is long backup type with external VA Rating 500VA 1000VA 1500VA 2000VA 3000VA battery. Real Power Rating 300W 600W 900W 1200W 1800W Display 2): The data above is for the standard ups, varying from the special units' of LED for outdoor UPS Indicator on Panel LED / LCD plus LED display (...
  • Page 7: Installation And Usage

    6. Installation and usage 5.2 Brief diagram and introduction of back panel: 6.1 Product installation 1)SNMP(Optional) 1.Close the equipments(for example: computer master),pull out the power wire from the main power socket 2)Output sockets 2.Put the UPS to the suitable position with good ventilation, at least 150mm 3)USB/RS232(Optional)...
  • Page 8: Maintenance

    2.Secondly, please plug UPS into main power, then turn on the input switch on the 6.2 Start/shut-down: rear panel. And then use multimeter to ensure UPS and battery connector's 1. On main power condition: Turn on the input switch on back panel of UPS, UPS polarity identification and voltage to be compliant (1.15 times as the ups rating will start self-testing and output through bypass and will be in normal condition DC voltage if the batteries are full).
  • Page 9 ◎The total power of load (power consumption) is calculated in unit of "Watt" 7.3 Outdoor UPS Parts: ◎If the marking of UPS just shows power capacity in "VA", we need to Lightning arrester multiply power factor(if no marking, it is 0.6) to calculate in unit of "Watt" Maintenance bypass switch ◎If there is just Ampere value marked, then multiply rated voltage and power DC input switch...
  • Page 10: Packing List

    Confirmation and Solution Phenomenon 1, whether Cable is loose. Main power is normal, main 2, whether fuse is burnt. power indicator is off whether fuse is burnt or not UPS can not stay in mains mode, After pulling out the UPS plug, use The mains power indicator is off with screwdrivers to revolve the fuse the buzzer ringing, even the UPS input...