Clearances to non-combustible construction
Material which is not capable of being ignited and burned, such as
materials consisting entirely of, or a combination of, steel, iron, brick
tile, concrete, slate, and plaster.
The power burner is designed for easy placement into built-in
masonry enclosures. For non-combustible applications the power
burner drops into the opening and hangs from its side flanges. A
deck is not required to support it from the bottom.
Do not use this appliance under unprotected overhead combustible
surfaces.
Fisher & Paykel recommends installing the manual shut-off valve
in a location readily accessible by the customer, so that gas to the
appliance can be shut off in an emergency situation. However, the
appliance must not be modified in any way to accommodate such
placement.
A spirit level should be used to ensure that the unit is level both
front-to-back and side-to-side. If it is not level, burner combustion
may be erratic or the unit may not function efficiently for grease
flow.
7

BUILT-IN CLEARANCES

a
CLEARANCE DIMENSIONS
A Minimum distance from non-combustible surface to power burner (above
the cook surface)
a
PBE1 MODELS
INCHES
MM
3
76