Download Print this page

FasTest PB-1015 Instructions

Pilot pressure booster repair kit

Advertisement

Quick Links

REPAIR KIT INSTRUCTIONS
Connector Maintenance:
A daily, weekly and periodic inspection of the booster and connectors by competent person
is recommended. User must establish a regular interval for maintenance as determined by
the user media and operational environment.
Inspection should include visual checks of the ports, hoses, hydraulic oil level, wear, dirt
accumulation and damage.
Use only original FasTest spare parts that are designed for the application and are subject
to strict quality control. See Warranty.
Safety Warnings – Guidelines:
If instructions are not completely understood by operator or components are missing,
contact FasTest before attempting use of the booster.
FasTest Pilot Booster & FE Connectors must only be used with test pieces of a specific
size as indicated by the part number. Improper use could cause separation of the connector
from the test piece resulting in physical harm or damage.
FasTest, Inc. Product Warranty
FasTest, Inc. warrants its products against defects of workmanship and/or material for 1 year from the date of the sale by FasTest, Inc.
This warranty is void if the product is misused, tampered with or used in a manner that is not in accordance with FasTest, Inc.
recommendations and/or instructions. FasTest, Inc. is not liable for consequential or other damages including, but not limited to, loss,
damage, personal injury, or any other expense directly or indirectly arising from the use of or inability to use its products either
separately or in combination with other products. ALL OTHER WARRANTIES EXPRESSED OR IMPLIED, WHETHER ORAL OR
WRITTEN, INCLUDING BUT NOT LIMITED TO WARRANTIES OR MERCHANTABILITY OR FITNESS FOR A PARTICULAR
PURPOSE ARE EXPRESSLY EXCLUDED.
Remedy under this warranty is limited to replacement of the product or an account credit in the amount of the original selling price, at
the option on FasTest, Inc. All allegedly defective products must be returned prepaid transportation to FasTest, Inc. along with
information describing the products performance, unless disposition in the field is authorized in writing by FasTest, Inc.
PB-1015 Pilot Pressure Booster Repair
Kit Instructions
Description: The PB-1015 Pressure Booster is a compact
pressure intensifier which uses compressed air to provide up to
600 psi hydraulic pressure. Designed to be used with a FasTest
FE Connector and Urethane Seal Set for sealing on external
threads and irregular surfaces.
Mounting U-Clamp
1/8" NPT
HYDRAULIC
"OUTLET" PRESSURE
PORT
Please thoroughly read and understand these repair instructions
prior to operating the Pilot Booster. For reference see WP016
for Pilot Booster Operating/Installation Instructions.
Dis-assembly Instructions
Re-assembly Instructions
Safety Warnings – Guidelines
Oil Cup
1/4" NPT AIR
"INLET" PRESSURE
PORT
Roseville, MN
Ph: 1-800-444-2373
Fax: 651-645-7390
www.fastestinc.com
WP161, Rev A 4/2/2019

Advertisement

loading

Summary of Contents for FasTest PB-1015

  • Page 1 FasTest, Inc. warrants its products against defects of workmanship and/or material for 1 year from the date of the sale by FasTest, Inc. This warranty is void if the product is misused, tampered with or used in a manner that is not in accordance with FasTest, Inc.
  • Page 2 10.Clean cap, piston and body. 12.Re-connect fittings into the inlet and outlet ports on booster. 13.Re-fill as required with petroleum based hydraulic oil. PISTON 14.Mount booster back into setup. See FasTest operating instruction WP016 for reference. BODY Roseville, MN Ph: 1-800-444-2373 Fax: 651-645-7390 www.fastestinc.com...