Ravas ProLine Touch Basic Operation Manual

Weighing terminal for hand pallet truck
Table of Contents

Advertisement

Quick Links

We would like to inform you about the fact that this RAVAS product is 100 % recyclable on the basis that the
parts are processed and disposed off in the right manner.
More information can be found on our website www.ravas.com.
Rev.20150617
Printing/typographical errors and model changes reserved
© RAVAS Europe b.v. • Toepadweg 7 • NL 5301 KA Zaltbommel Postbus 2023 • Tel.: +31 (0)418 - 515220
Operation Manual
ProLine Touch
Basic
Weighing Terminal For
Hand Pallet Truck
Fax: +31 (0)418-515320 • E-mail: info@ravas.com
MOBILE WEIGHING

Advertisement

Table of Contents
loading
Need help?

Need help?

Do you have a question about the ProLine Touch Basic and is the answer not in the manual?

Questions and answers

Subscribe to Our Youtube Channel

Summary of Contents for Ravas ProLine Touch Basic

  • Page 1 Weighing Terminal For Hand Pallet Truck We would like to inform you about the fact that this RAVAS product is 100 % recyclable on the basis that the parts are processed and disposed off in the right manner. More information can be found on our website www.ravas.com.
  • Page 2: Operation Manual Ravas Proline Touch Basic Rev. 6

    Operation Manual RAVAS Proline Touch Basic Rev. 6...
  • Page 3 Operation Manual RAVAS Proline Touch Basic Rev. 6...
  • Page 4 Please Note: While every precaution has been taken in the preparation of this manual, RAVAS Europe b.v. assumes no responsibility for errors or omissions. Neither is any liability assumed for damages resulting from the use of the information contained herein.
  • Page 5: Table Of Contents

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Contents 1 Introduction ............................7 1.1 The Weighing Hand Pallet Truck ..................... 7 1.1.1 Startup ......................... 7 1.1.2 Operation ........................7 1.1.3 Maintenance ........................ 8 2 Weighing Terminal ..........................9 2.1 Documentation ......................... 9 2.2 Safety Advice ..........................
  • Page 6 Operation Manual RAVAS Proline Touch Basic Rev. 6 6.5.3 Recipe Weighing: Filling A Component ..............28 6.6 Overview Data Entry ......................29 6.6.1 Data Entry ......................... 29 6.6.2 Data Entry: Product File ................... 30 6.6.3 Data Entry: Tare Memory ..................31 6.6.4 Data Entry: ID Memory .....................
  • Page 7: Introduction

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Introduction The Weighing Hand Pallet Truck 1.1.1 Startup Press -key to switch the terminal on. After approx. 3 to 5 minutes the electronics and the loadcells have reached their operating temperature. Before that deviations of up to 0.3% may occur.
  • Page 8: Maintenance

    1.1.3 Maintenance The calibration of every scale must be checked at regular intervals. RAVAS recommends maintenance of the weighing system once a year. Scales subject to Weights & Measures approval must be verified with certified test weights every year by a certified organization.
  • Page 9: Weighing Terminal

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Weighing Terminal This manual describes the basic functions and the operation of the Proline Touch weighing terminal with the operator interaction in the individual steps of the operating sequence. The terminal is intended for connection to 12 V DC power supply (–15%) to 30VDC (+10%).
  • Page 10: Weight Display And Scale Function Keys

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Weight Display And Scale Function Keys Electronic marking plate Net w eight Charge st at e symbol (bat tery operat ion) Min load Division e / d Unit Max load Scale-No. /...
  • Page 11: Numeric / Alphanumeric Keyboard (Example)

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Weight Display Scale-No. No. Of Weighing Range W1.1 … W1.3 partial weighing range for multiple-range scales. No-Motion Symbol Settled weight (printing / storing enabled). Gross Weight Or e.g. 1250 Switching from gross weight to Net Weight e.g.
  • Page 12 Operation Manual RAVAS Proline Touch Basic Rev. 6 With the '123...' key the layout can be switched back to the template for numeric inputs.
  • Page 13: Operation Of Scale Functions

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Operation Of Scale Functions Preset Tare (PT) After pressing the PT-key, the template for numeric inputs is opened and a tare value can be entered and confirmed with the Enter-key. Display of net weight in the main display and of tare weight in the auxiliary display.
  • Page 14: Operation Via Display And Keyboard

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Operation Via Display And Keyboard Power On Press -key to switch the terminal on. After switching the terminal on, automatically the power up messages are displayed, then the program proceeds to the template 'main menu'.
  • Page 15: Main Menu

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Main Menu Weighing mode Weighing Counting mode Counting Operating mode loading / unloading Load / Unload Summing mode Totalizing Recipe weighing mode Recipe Weighing Operating mode determination of center of load. Gravity Determination Note: Must be enabled in menu 'Gravity parameters'.
  • Page 16: Special Functions For Mobile Weighing

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Special Functions For Mobile Weighing The weighing terminal features a power save mode and remains in sleep mode when external power is on. To switch the terminal on press -key. Power off on battery low If the input voltage falls below 11.3 V a blinking 'Battery Low' signal is shown.
  • Page 17: Operating Sequence

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Operating Sequence Operating Mode 'Weighing' In the operating mode 'Weighing' the terminal works as a simple indicator with optional entry of IDs. Automatic and manual taring is supported as well as zero setting. On keystroke, capturing of weight is started and -if applicable- depending on the configuration in the menu 'Data input/Settings/General' a ticket is printed, a data string transmitted and a record stored in the internal memory.
  • Page 18: Weighing: Input Of Id

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.1.2 Weighing: Input Of ID Entry step for ID. Abort entry, changes are ignored. Confirm entry. 6.1.3 Weighing: Load Scale This message appears when the weight on the scale is below the min. load or if it is not different from the weight of the previous weighing.
  • Page 19: Operating Mode 'Counting

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Operating Mode 'Counting' In the operating mode 'Counting' the weighing terminal works as a simple parts counting station with optional entry of IDs. On keystroke capturing of weight is started and -if applicable- depending on the configuration in the menu 'Data input/Settings/General' a ticket is printed, a data string transmitted and a record stored in the internal memory.
  • Page 20: Counting: Select Product

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.2.2 Counting: Select Product Select product from file. Show previous record in file. < Show next record in file. > Delete record from file. Delete Create new record in file. Store changes.
  • Page 21: Counting: Tare Memory

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.2.4 Counting: Tare Memory Select tare weight from tare memory. Select previous record in tare memory. < Select next record in tare memory. > Delete record from tare memory. Delete Create new record in tare memory.
  • Page 22: Counting: Calculation Of Average Piece Weight

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.2.5 Counting: Calculation Of Average Piece Weight Capturing of average piece weight by adding / removing parts. Return to previous menu. Back Change the preset number of 10 parts. Parts Confirm displayed number of pieces.
  • Page 23: Operating Mode 'Loading / Unloading

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Operating Mode 'Loading / Unloading' In the operating mode 'Loading / unloading' the weighing terminal works as a data capture station with optional tare memory. 6.3.1 Loading / Unloading: Storage Sequence for loading and unloading to a specified target value.
  • Page 24: Loading / Unloading: Select Key

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.3.3 Loading / Unloading: Select Key Select already chosen or new key. Return to previous menu. Back  Select key. 6.3.4 Loading / Unloading: Weighing Entry of ID and start of weighing or termination of weighing.
  • Page 25: Operating Mode 'Summing

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Operating Mode 'Summing' In the operating mode 'Summing' the weighing terminal works as a totalizing scale with optional tare memory. 6.4.1 Totalizing Memory Operating sequence summing without preset target. Return to previous menu.
  • Page 26: Totalizing Memory: Select Key

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.4.3 Totalizing Memory: Select Key Select already chosen or new key. Return to previous menu. Back  Select key. 6.4.4 Totalizing Memory: Weighing Entry of ID and start of weighing or termination of weighing.
  • Page 27: Operating Mode 'Recipe Weighing

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Operating Mode 'Recipe Weighing' 6.5.1 Recipe Weighing Operating sequence recipe weighing. Return to main menu. Back  Select key. 6.5.2 Recipe Weighing: Assign New Key Entry of recipe name. Return to main menu.
  • Page 28: Recipe Weighing: Filling A Component

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.5.3 Recipe Weighing: Filling A Component Filling of a component. Return to main menu. Back Termination of the recipe in progress. Parts Confirm entries.  Fill component and confirm.
  • Page 29: Overview Data Entry

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Overview Data Entry The data entry menu contains the configuration settings, database entries and the backup of data. If the unit is switched on for the first time, first the master file data should be entered.
  • Page 30: Data Entry: Product File

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.6.2 Data Entry: Product File Data for up to 99 products with their product names can be stored in the product file against a 2-digit product- Show previous record in file. <...
  • Page 31: Data Entry: Tare Memory

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.6.3 Data Entry: Tare Memory Up to 50 tare weights with their pertaining designation can be stored in the tare file against a 2-digit tare-No. Select previous record in tare memory. <...
  • Page 32: Data Entry: Id Memory

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.6.4 Data Entry: ID Memory Up to 99 IDs can be stored in the ID file against a 2-digit ID-No. Select previous entry in ID file. < Select next entry in ID file.
  • Page 33: Data Entry: Data Backup

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.6.5 Data Entry: Data Backup Weighing data and the contents of the database can be copied onto a USB device. In the other direction, the database can be restored. Return to main menu.
  • Page 34: Data Entry: Settings

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Data Entry: Settings Only trained service personnel may make / change configuration settings. Note: If no password is specified, password check is skipped. The password can be entered in the menu 'Data entries\Settings\General'.
  • Page 35: Data Entry / Settings / General

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.7.1 Data Entry / Settings / General Return to previous menu. Exit Confirm entries. Entry of unequivocal terminal-No. Terminal-No. Entry of date in format DD.MM.YY Date Time Entry of time in format HH.MM Entry of min.
  • Page 36: Data Entry / Settings / Iforks Settings

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Max.No of columns in Entry of the max. number of columns in the operating mode 'Load / unload'. load/unload Totalizing ID1 – ID4 Prompts for the entry of IDs in the operating mode 'Summing'.
  • Page 37: Data Entry / Settings / Wlx Settings

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.7.3 Data Entry / Settings / WLX Settings For a detailed description of the individual WLX parameters refer to technical manual 'WLX IAE'. Note:  The WLX menu appears only when an WLX module is installed.
  • Page 38: Data Entry / Settings / Printer Settings

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.7.4 Data Entry / Settings / Printer Settings Return to previous menu. Exit Confirm choice. With Printer Enable / disable printer. Enable / disable multiple printouts. Multiple Printouts Printer language Select printer language (only for operation mode 'Weighing'):...
  • Page 39: Data Entry / Settings / Gravity Parameter

    Operation Manual RAVAS Proline Touch Basic Rev. 6 6.7.5 Data Entry / Settings / Gravity Parameter Return to previous menu. Exit Confirm choice. With Gravity Determination Enable / disable gravity determination. Note: After enabling the function and confirming the parameters, the application is automatically restarted.
  • Page 40: Data Transmission And Saving To File

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Data Transmission And Saving To File If data transmission is enabled in the menu 'Data Entry/Settings/General', after each weighing cycle data are transferred to the host system. When the 'AckNak' protocol is used, receipt of data must be confirmed by the host system with ACK(06H) within 3 sec.
  • Page 41 Operation Manual RAVAS Proline Touch Basic Rev. 6 Note: Data transmission and saving to file use the same structure of the data string. Field Max. length Format Terminal-No. numeric Date Format depending on configuration Time Format HH:MM Alibi-No. numeric (number of record in data archive)
  • Page 42: Printformats

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Printformats Weighing 12345678901234567890123456789012345678901234567890123456789012345678901234567890 Terminal-No. Date 08.01.15 Time 14:42 Consec-No. Gross 11.0 kg 10.0 kg Tare 1.0 kg 1000 Counting 12345678901234567890123456789012345678901234567890123456789012345678901234567890 Terminal-No. Date 08.01.15 Time 14:47 Consec-No. Ref.Weight Scale-No. Parts Gross 7.4 kg 6.4 kg...
  • Page 43: Load / Unload

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Load / Unload 8.3.1 Subtotal 12345678901234567890123456789012345678901234567890123456789012345678901234567890 Identification Load Terminal-No. Date 09.01.15 Time 08:28 Countername Consec-No. Gross 15.2 kg 14.2 kg Tare 1.0 kg Subtotal 14.2kg 8.3.2 Summe 12345678901234567890123456789012345678901234567890123456789012345678901234567890 Identification Load Terminal-No. Date 09.01.15...
  • Page 44: Summing Mit Single- Und Total Weight

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Summing mit Single- und Total weight 8.4.1 Singelweighing 12345678901234567890123456789012345678901234567890123456789012345678901234567890 10000 123456 Countername Consec-No. Gross 19.8 kg Tare 1.0 kg 18.8 kg Date 09.01.15 Time 08:32 8.4.2 Summing 12345678901234567890123456789012345678901234567890123456789012345678901234567890 Summing: Countername Tot. Gross Total 90.4 kg...
  • Page 45: Data Archive

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Data Archive A record -secured with checksum- is stored for every completed weighing transaction in the internal data archive, consisting of weight, date and consecutive Id-No. The Id-No. is reset to 0001 with every change of the date.
  • Page 46: Transport, Maintenance And Cleaning

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Transport, Maintenance And Cleaning 10.1 Transport Notes:  Transport and storage of electronic components such as boards, EPROMS, etc. must only be made in suitable anti-static ESD bags or cases.  Storage temperature –25 to +70°C at 95% max. relative humidity without condensation.
  • Page 47: Trouble Shooting

    Operation Manual RAVAS Proline Touch Basic Rev. 6 Trouble Shooting CAUTION This unit does not contain any customer serviceable parts! Only permit qualified personnel to service this equipment. Exercise care when making checks, tests, and adjustments! If any problem arises that has not been explained above, please follow this check list: ...
  • Page 48: Error Messages

    Operation Manual RAVAS Proline Touch Basic Rev. 6 11.1 Error Messages If an error occurs during calibration or normal operation, error messages are displayed as follows: Error Message Possible Cause Corrective Measure  Jumper for protection of  Set calibration jumper to...
  • Page 49 Operation Manual RAVAS Proline Touch Basic Rev. 6 Error Message Possible Cause Corrective Measure  Scale in overload  Unload scale -------- Overload  CPU does not receive data  Check internal and external from weighing interface wiring and cabling Powerup Out of Range ...

Table of Contents