Summary of Contents for Cavity Sliders Solic CS005

  • Page 1 SOLIC OPERATION MANUAL AUTOMATIC SLIDING DOOR OPERATOR Microcomputer Control Type MODEL - CS005 Motor - M005 (Hypoid gear type) Before using this door operator, you should first thoroughly read this manual and keep for future reference.
  • Page 2 1. FEATURES 1. Digital counter for door cycles The digital counter on the microcomputer control box counts the number of cycles the door completes over its life. A cycle is one movement open and then closed. This number is memorised even if the power is turned OFF. This counter is useful for maintenance requirements.
  • Page 3 2. SPECIFICATIONS (Motor M005 – Microcomputer control box C005) MODEL M005 (Telescopic) Power supply AC 220V ± 10% 3A 50/60Hz AC 120V ± 10% 3A 50/60Hz Applicable types ADD-ON DC, CN Max. door weight DC type: 100 kg for Single door leaf, 85kg x 2 for Bi-Parting Safety function Safety turn in full speed section...
  • Page 4 3. WIRING 1. Example wiring – Optional parts are marked with...
  • Page 5 SAFETY BEAM 8*0.5 mm2 CONTROLLER DOOR POWER OUTLET CONTROLLER 120 / 230VAC-3A INPUTS • Slides up and down to adjust heigh of belt or to separate from drive ba • Loosen front screws to adjust 2*0.5mm2 15*0.5mm2 11*0.5mm2 3*1mm2 F = Front. Must face Lock SW1 Lock SW2 (visible) when instal...
  • Page 6 • OPENING WIDTH ADJUSTMENT Connect wire of a variable resistor of up to 1K Ω for door opening width adjust to be connected to this INPUT. It adjusts the door opening width. To widen, turn it clockwise. - Terminal E and F on advanced input Plug. 5.
  • Page 7: Opening Direction

    3. SLOW CLOSE DISTANCE (%) The slow close distance sets the door deceleration start position 0 ~ 100% (25mm ~ 355mm). The closing distance is adjustable using the potentiometer on the front of the controller. The position is set at 50% when delivered. 4.
  • Page 8 7. 18PIN FEMALE CONNECTION Connection point for the 18pin male connector plug from the transformer input pack. Connects the power, safety beams, and activation devices from the transformer plugs to the controller. 8. 8PIN FEMALE CONNECTION Connection point for the 8pin male connector plug from the CS motor M005. 9.
  • Page 9 The digital LED monitor on the microcomputer control box CS005 shows the following setting values: (1) Monitor (2) Display information during initial (first) movement TEACH: During initial movement -Controller is learning the open and closed positions of the door. (3) Adjusting the settings for hold open timer, closing speed and slow close distance ①...
  • Page 10 ③ Setting of closing speed (100~500mm/s) CLS: Closing speed variable every 25mm/s between 100 to 500mm/s on adjustment screw pot. ④ Setting of slow close distance after braking (0~100%) SCd: Slow close distance variable every 5% between 0% up to 100% on adjustment screw pot.
  • Page 11: Dip Switch Functions

    6. DIP SWITCH FUNCTIONS WARNING: Turn off the power to the controller before changing any of the dip switch settings. Changing the settings while power is ON can irreversibly damage the controller. Turn OFF the power. Wait 5 seconds for the power to drain from the controller and be completely off.
  • Page 12 DIP SWITCH 4: FUNCTION - Dependent on selection of dip switch 5. If dip switch 5 is ON/UP (Auto Door Mode) PUSH TO OPEN When the door is fully closed. If door is opened 2cm by hand, the door can be set to self-open or stay closed.
  • Page 13 DIP SWITCH 8: LOCK LK001 or LK002 Selected by the lock LK001 type, or Hypoid lock (LK002) which is connected to the 4pin male connector plug on the microcontroller. State Setting ON (UP) DL TYPE: The lock DL type (or PL type) is connected. OFF (DOWN) KL TYPE: The Hypoid lock type is connected.
  • Page 14 7. HYPOID GEAR MOTOR SH-17H Motor SH-17H 1. D connector (8 pin male plug) Lead the wire of D connector to the 8-pin female connector of the microcomputer control box CS005 2. F connector (4 pin male plug) The connector is for optional motor lock - LK01. Lead the wire of the lock to the F connector to the 4-pin female connector of the microcomputer control box CS005.
  • Page 15 CHECKS TO MAKE BEFORE POWER IS CONNECTED TO THE UNIT Setting and checks before the power is turned ON 1) Set the door opening direction by the selector (L: Left Hand, R: Right Hand) provided on the microcomputer control box CS005 (PAGE 7) DO NOT CHANGE SWITCH WHILE POWER IS ON TO AVOID CONTROLLER DAMAGE Turn power OFF, wait 5 sec to drain power.
  • Page 16 9. DISPLAY INFORMATION FOR ERROR CODES/FAULTS Fault list for microcomputer control box CS005 Error codes are displayed on the LED display as [Err xx]. The following two numbers after the “Err” notation indicates the error that has occurred. The following list of error codes can be indicated on the CS005 Microcontroller. Error Error/Fault Error/Fault...