Hazard generated by current Hazard generated by human error Hazard generated by current during cleaning work General Directions for use Assembly Function- and installation diagram Add the Device into the Loxone Config 10.1 Initial setup 10.2 Re-learning in process: Electrical Connection Technical data Connection diagram for pump and Praher ball valve EO510 13.1...
This operation manual supplement the instructions provided by existing accident prevention and environmental protection regulations. It must be available at the place of utilization of the equipment at any time and must be read by each person intending to use the Loxone Aquastar Air . This means ...
Insufficient monitoring of components subject to wear and tear Inadequately performed repair of the Loxone Aquastar Air Damage of the Loxone Aquastar Air resulting from foreign matter or Force Majeure Enduring damage due to neglect of the operation manual or due to damaging sealed parts lead to a lapse of the warranty.
Page 6
the electrical connection must have separating device built into the permanently installed electrical installation, which enables the disconnection of all electrical contacts with a contact space of min. 3 mm from the mains. Pay attention that the supply voltage is correctly protected and an earth-leakage circuit breaker ≤...
“Filter”! Directions for use The following is a control unit for a Praher 6-way valve that is operated using a Loxone miniserver. The Loxone Aquastar Air backwashes a filter fully automatically via time and pressure and controls the pump of a swimming pool as well as various extensions for the Loxone control unit.
As filter medium can be washed out during backwashing and rinsing, we recommend fitting the drain with a throttle. Otherwise a stuck valve disk can adversely affect the flawless functioning of the Aquastar. Polluted or grainy filtering media require the use of adequate pre filters.
Add the Device into the Loxone Config Before being able to use the Loxone Aquastar Air, it must be learnt-in. To do this the Aquastar needs to be in learing mode. 10.1 Initial setup When the Loxone Aquastar Air is powered up for the first time, the learning mode will start automatically.
Page 10
Now, open Loxone Config and connect to your Miniserver. Click then on the Air Base Extension and check the checkbox "Start and Dispaly Air Monitor". Now click on 'Start Search'. All Air devices in learning mode will be listed. Now select the device you want to learn in, enter a name and click on "Create Device".
The PS1 terminal is intended for an evaluation of 0-10V. The maximum voltage is +24V PS1 GND 10V. The 0...0.3 or 0…6 bar Loxone pressure sensor is optionally available. f) Pressure sensor for Praher Pressure Sensors (System Pressure) The PS1 terminal is intended to evaluate 0.5-4.5V. The maximum voltage is 5V.
Technical data Voltage: 100-240V AC 50/60 Hz Protection: IP 65 Frequency: 50-60 Hz 15 Watt 11/2“, 2“ Max. Power: Connection diagram for pump and Praher ball valve EO510 13.1 Connection diagram for one phase pump 13.2 Connection diagram for three phase pump www.praherplastics.com...
Exploded view drawing Loxone Aquastar Air Aquastar lid with foam rubber cord Hexagon screw Gear motor Aquastar body bottom Cabel with Connector plug for pressure sensor V6ND valve 1 ½”, 2” Control board Pressure sensor (only at Aquastar 4001) Pump end switch...
Dismantling Loxone Aquastar Air For dismantling the electronic drive off the valve a box spanner with a wrench size of 15mm is needed. Carry out Installation in reverse order (step 8 – 1) Inspection glas (step 2) and hexagon screw (step 4) to be screwed stalwartly (4Nm – 8Nm)
The drive continually triggers the backwash cycle o The system contains pressure boosting components (e.g., Solar absorbers) Set the pressure sensor in such a way that the Loxone Aquastar Air does not trip even at increased pressure The pump fails to switch on or off o Relay is burnt-out ...