24 Month Warranty; Specifications - Innovative Energies No-Break SR250i 485 Series User Manual

For use with optional modbus protocol converter
Table of Contents

Advertisement

Global Solutions Personal Focus

♦ 24 Month Warranty

SPECIFICATIONS

All specifications are typical at nominal input, full load and at 20°C unless otherwise stated.
ELECTRICAL
Input Voltages
▪ standard
180V - 264V, 45-65Hz
88V - 132VAC (internal link select)
▪ optional
88-135VDC (specify at time of order)
Internal input fuse, output battery fuse
Fusing / Protection
1KV DC input - output / earth
Isolation
> 85%
Efficiency
Soft start circuit
Inrush current
250W continuous (0 - 50°C)
Output Power
13.8/ 27.6/ 34.5/ 41.4/ 55.2V
Output Voltages
85 - 105% of Vout
Voltage adj. range
Temperature sensor on 1.7m lead with adhe-
Temp. Compensation
sive pad: -4mV / °C / cell ±10%
Straight line profile
Current Limit
<0.2% over AC input range
Line Regulation
<0.4% open circuit to 100% load
Load Regulation
<1%
Noise
0.03% / °C
Drift
15 - 20 ms (nom. - max. Vin) without battery
Hold-up time
Automatic current de-rating if >50°C. Self-
Thermal Protection
resetting.
Over-voltage protection on output
Overvoltage protection
at ~ 130% of nominal output voltage
EMI
CISPR 22 / EN55022 class A
Safety
IEC950 / EN60950 / AS/NZS3260
Specifications are subject to change without notice. No liability accepted for errors or omissions.
High performance No-Break
Separate outputs for load and battery
Battery detection - regular battery presence and
battery circuit integrity checks
Deep discharge protection for batteries
Battery condition test (BCT) standard for models
with communication port option
Overload, short circuit & reverse polarity protec-
tion for battery
Automatic battery temperature compensation
Optional serial communication interface allows
Optional
remote monitoring & user control of BCT function -
+PROTOCONMB
RS485 converter for
i and V versions
use with SR250i -485
No transition switching between PSU & battery
versions
LED flash codes for precise state indication
"Mains" & "Battery System" alarm relay outputs
No-Break™ FUNCTIONS AND ALARMS*
Battery Charge Limit
Reverse Polarity
Battery Monitoring
Battery Protection
- battery discharged
- overload (*refer to
options - ECB)
- short circuit
Indication LEDs
Alarms
Alarm Relay contacts
Battery Condition Test
(BCT)
Standby Mode
ENVIRONMENTAL
Operating
temperature
Storage temperature
Humidity
Cooling
250W PSU/Charger with communication options
TM
DC UPS system
See Model Table for default settings -
may be increased to PSU rated current
Battery reverse connection will open internal
fuse (and produce alarm)
Detects for presence of battery on start up,
then every 60 minutes when charge current <
200mA
Electronic Circuit Breaker (ECB) operates
under the following conditions:
ELVD (electronic low voltage disconnect)
activates when battery voltage drops to 1.67V/
cell (adjustable) - auto reset
Allows ~150% load from battery without act-
ing, operates within 300ms for total load >
600%
Acts within 2ms, backed up by fuse
Green: Battery System OK, Power OK
Red:
Standby
Mains Fail (Mains or PSU fail, standby
mode)
Battery System OK - alarms when battery
voltage low (on mains fail) , battery
missing, battery circuit wiring faulty, BCT
fail (if enabled)
C - NO - NC full changeover rated 1A /50V
DC, 32VAC
Standard on SR250i & V - 20mins/28days
unless otherwise specified on ordering.
Turns off DC output of PSU & allows load to
run off battery
0 - 50 °C ambient at full load
De-rate linearly >50 °C to 0 load @ 70 °C
-10 to 85 °C ambient
0 - 95% relative humidity non-condensing
Natural Convection except for 12V model
(fan)